US$369.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 6167-2007: Methods for testing the performance of airborne particle counter Status: Valid GB/T 6167: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 6167-2007 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Methods for testing the performance of airborne particle counter
| Valid |
GB/T 6167-2007
|
GB/T 6167.1-1985 | English | 239 |
Add to Cart
|
2 days [Need to translate]
|
Methods for testing the performance of dust particle counter--Calibration for sizing particle
| Obsolete |
GB/T 6167.1-1985
|
PDF similar to GB/T 6167-2007
Basic data Standard ID | GB/T 6167-2007 (GB/T6167-2007) | Description (Translated English) | Methods for testing the performance of airborne particle counter | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | P46 | Classification of International Standard | 91.140.30 | Word Count Estimation | 14,113 | Date of Issue | 2007-09-11 | Date of Implementation | 2008-02-01 | Older Standard (superseded by this standard) | GB/T 6167.1-1985; GB/T 6167.2-1985 | Regulation (derived from) | China National Standard Approval Announcement2007 No.10 (Total No.110) | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the principles and methods of performance test dust particle counter test standard particle generating apparatus. This standard applies to the use of light scattering theory, the particle size of the sampled air suspended particles 0. 1��m ~ 10. 0��m size and number of particles of dust particle counter measurements. This class is mainly used for dust particle counter cleanliness testing and performance testing of air filters and filter clean room. |
GB/T 6167-2007: Methods for testing the performance of airborne particle counter---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for testing the performance of airborne particle counter
ICS 91.140.30
P46
National Standards of People's Republic of China
Replacing GB/T 6167.1 ~ 6167.2-1985
Dust particle counter performance test method
Posted 2007-09-11
2008-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
From the date of implementation of this standard instead of GB/T 6167.1-1985 "dust particle counter performance test method conversion sensitivity" and
GB/T 6167.2-1985 "dust particle counter performance test method for particle number concentration."
This standard and GB/T 6167.1-1985, the main changes compared to the GB/T 6167.2-1985 are as follows.
--- Get a response voltage of each size range with PSL and multi-channel pulse height analyzer (PHA);
--- Make a size range with a voltage corresponding to the relationship between the signal generator;
--- Test method for determining airborne particle counter for counting response, counting efficiency and maximum saturation concentration.
The Standard Appendix A, Appendix B are normative appendix.
The standard proposed by the People's Republic of China Ministry of Construction.
This standard by the National HVAC and purification equipment Standardization Technical Committee.
This standard is drafted by. China Academy of Building Research.
Participated in the drafting of this standard. Tianjin University, Jiangsu Su net Group Co., Ltd., Suzhou Huada Equipment Co., Ltd., Suzhou City, a hundred God
Technology Co., Ltd., Suzhou Hong Rui purification Technology Co., Ltd., Suzhou City Arima purification equipment Limited, Canadian wild Max Instrument (Shenyang) have
Limited.
The main drafters of this standard. Wang Junshan, Song Ye-hui, Liu Junjie Zhu can.
This standard replaces the standards previously issued as follows.
--- GB/T 6167.1 ~ 6167.2-1985.
Dust particle counter performance test method
1 Scope
This standard specifies the principles and methods of performance test dust particle counter test standard particle generating apparatus.
This standard applies to the use of light scattering principle, ~ 10.0μm aerosol particle size and number of air sampling particle diameter of 0.1μm
Conduct airborne particle counter measurement. Such dust particle counter is mainly used to detect and cleanliness of the air filter and the filter clean room
Performance testing.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 16803 heating, ventilation, air cleaning terminology
GB 50073 clean plant design specifications
3 Terms and Definitions
GB/T 16803, GB 50073 and determined the following terms and definitions apply to this standard.
3.1
Solid and liquid particles suspended in air.
3.2
Having a particle size and refractive index of the test particle counter and use are known, and the particle diameter uniform spherical monodisperse particles having
Geometric standard deviation of less than 1.15. Commonly used polystyrene latex (PSL).
3.3
That is indicated on the instrument display particle size value.
3.4
The maximum concentration of particles of dust particle counter can be accurately measured by a dust particle counter determines the structure itself.
3.5
Dust particle counter sampling port in inhaled air sampling, particle concentration of dust particle counter is displayed (C) and suspended particles
The actual particle concentration (C0) ratio.
3.6
Dust particle counter has the ability to distinguish similar particle diameter.
3.7
Dust particle counter displays the difference between the ratio of the standard particle size of the particle size and particle size standard.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 6167-2007_English be delivered?Answer: Upon your order, we will start to translate GB/T 6167-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 6167-2007_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6167-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 6167-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6167-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|