US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 6111-2018: Thermoplastics piping systems for the conveyance of fluids -- Determination of the resistance to internal pressure Status: Valid GB/T 6111: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 6111-2018 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Thermoplastics piping systems for the conveyance of fluids -- Determination of the resistance to internal pressure
| Valid |
GB/T 6111-2018
|
GB/T 6111-2003 | English | 120 |
Add to Cart
|
0--9 seconds. Auto-delivery
|
Thermoplastics pipes for the conveyance of fluids -- Resistance to internal pressure -- Test method
| Obsolete |
GB/T 6111-2003
|
GB/T 6111-1985 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Standard test method for time-to-failure of thermoplastic pipe under constant internal pressure
| Obsolete |
GB/T 6111-1985
|
PDF similar to GB/T 6111-2018
Standard similar to GB/T 6111-2018 GB/T 3830 GB/T 8801 GB/T 5836.2 GB/T 4455
Basic data Standard ID | GB/T 6111-2018 (GB/T6111-2018) | Description (Translated English) | Thermoplastics piping systems for the conveyance of fluids -- Determination of the resistance to internal pressure | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | G33 | Classification of International Standard | 83.140.30 | Word Count Estimation | 22,217 | Date of Issue | 2018-03-15 | Date of Implementation | 2018-10-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 6111-2018: Thermoplastics piping systems for the conveyance of fluids -- Determination of the resistance to internal pressure ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Thermoplastics piping systems for the conveyance of fluids--Determination of the resistance to internal pressure
ICS 83.140.30
G33
National Standards of People's Republic of China
Replacing GB/T 6111-2003
Thermoplastic pipe system for fluid delivery
Resistance to internal pressure
(ISO 1167-1.2006, Thermoplasticspipes, fittingsandassembliesfor
Part 1.General method;ISO 1167-2.2006,Thermoplasticspipes,fittingsand
internalpressure-Part 2.Preparationofpipetestpieces;ISO 1167-3.2007,
Determinationoftheresistancetointernalpressure-Part 3.Preparationof
Components;ISO 1167-4.2007,Thermoplasticspipes,fittingsandassemblies
pressure-Part 4.Preparationofassemblies,NEQ)
2018-03-15 Release.2018-10-01 Implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Administration released
Directory
Preface I
Introduction II
1 Scope 1
2 Normative references 1
3 Terms and Definitions 1
4 Principle 2
5 Test parameters 2
6 Test Equipment 2
7 Sample 4
8 Calculation of test pressure 4
9 Test Instrument Calibration and Accuracy 5
10 Condition Adjustment 5
11 Test Step 6
12 Test Report 6
Appendix A (Normative) Preparation of Pipe Specimen 8
Appendix B (Normative) Preparation of Component Specimens 10
Appendix C (Normative Appendix) Preparation of Assembly Samples 17
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 6111-2003 "Test method for internal pressure resistance of thermoplastic pipes for fluid transfer" and GB/T 6111-
Compared with.2003, the main technical changes are as follows.
--- The scope has been expanded from "pipe" to "pipe, components and assemblies" (see Chapter 1);
--- Added the following terms. component (3.1), standard size ratio (3.2), free length (3.3);
--- The average temperature of the oven, modified from 3-1 °C to 2-1 °C (6.2);
--- Added "size measuring device" requirement (6.8), deleted "thickness gauge" and "pipe average outer diameter ruler";
--- Increased and modified sample types and related requirements (see Chapter 7);
--- Increased the calculation method of test pressure. According to the nominal size of the sample and the pressure calculation method according to SDR (8.3, 8.4);
--- Increased the "test has been carried out for 500h ~ 1000h" when the treatment method (11.3);
---In the test report, "f) "Sample preparation conditions" and "l) Condition adjustment time" are added (see Chapter 12);
--- Deleted the original standard data Appendix A;
--- Increased the normative appendix A, appendix B, appendix C, respectively, the pipe, assembly, assembly sample preparation requirements.
This standard uses redrafted reference ISO 1167-1.2006 "Thermoplastic Pipes, Components and Assemblies for Fluid Conveyance
Determination of Pressure Properties - Part 1. General Test Methods, ISO 1167-2.2006, Thermoplastic Pipes, Components and Combinations for Fluid Delivery
Determination of internal pressure resistance of parts - Part 2. Preparation of pipe samples", ISO 1167-3.2007, Thermoplastics pipes for fluid transport,
Determination of internal pressure resistance of components and assemblies - Part 3. Preparation of component specimens", ISO 1167-4.2007 "Thermoplastics for fluid transport
Determination of resistance to internal pressure properties of plastic pipes, assemblies and assemblies - Part 4. Preparation of assembly specimens", prepared with ISO 1167.
The consistency of.2006/2007 is not equivalent.
Please note that some of the contents of this document may involve patents. The issuing agency of this document does not assume responsibility for identifying these patents.
This standard is proposed by China Light Industry Federation.
This standard is under the jurisdiction of the National Plastic Products Standardization Technical Committee (SAC/TC48).
Drafters of this standard. Yonggao Co., Ltd., National Plastic Products Quality Supervision and Inspection Center (Fuzhou), Wuhan Jinniu Economy
Development Co., Ltd., Chengde Precision Testing Machine Co., Ltd., Chengde Jinjian Testing Instrument Co., Ltd., Xiamen Sandeng Plastic Industrial Co., Ltd.
Secretary, Hebei Baoshuo Pipe Co., Ltd.
The main drafters of this standard are. Huang Jian, Lin Wei, Liu Feng, Wang Xinhua, Ren Yufeng, Sun Huali, Yan Xusheng, and Wang Zhibin.
The previous versions of the standard replaced by this standard are.
--- GB/T 6111-1985, GB/T 6111-2003.
Introduction
This standard will be ISO 1167-1.2006 "Determination of internal pressure resistance of thermoplastic pipes, components and assemblies for fluid transport.
Part 1. General test methods, ISO 1167-2.2006, "Insulation resistance of thermoplastic pipes, components and assemblies for fluid transport
Determination of Part 2. Preparation of Pipe Specimen, ISO 1167-3.2007, Thermoplastic Pipes, Components and Assemblies for Fluid Delivery
Determination of internal pressure properties - Part 3. Preparation of component specimens", ISO 1167-4.2007, Thermoplastics pipes, components for fluid transport, and
Measurement of the inner pressure resistance of the assembly Part 4. Preparation of the assembly test piece. The four parts were combined into one text, redrafted, packaged
Including editorial changes, the main technical differences between this standard and ISO 1167 are as follows.
--- Consolidation of the four parts of ISO 1167 into one text, technical content of ISO 1167-2, ISO 1167-3, ISO 1167-4
Do not use this standard normative appendix A, appendix B, appendix C;
--- Normative references have been replaced or increased or decreased using domestically relevant similar standards;
In the text, where there are national standards that correspond to international standards, national standards are used instead of directly adopting international standards;
--- Increased the normative reference document GB/T 19278-2003;
--- Uniformly modify the pressure unit involved in the standard to China's statutory unit MPa "MPa";
--- Modify Figure 1, and mark the free length in the figure;
--- The formulas were numbered to comply with the relevant provisions for the drafting of China's national standards;
--- Added "Type A type sealing joint when performing arbitration test";
--- Added "pipe arbitration test using measuring dimensions to calculate test pressure";
--- Modify the "minimum state adjustment time" requirement to "state adjustment time" and give the deviation.
Thermoplastic pipe system for fluid delivery
Resistance to internal pressure
1 Scope
This standard specifies tests for determining the resistance to internal pressure of thermoplastic pipes, components and assemblies for fluid delivery at a given temperature.
method.
This standard applies to water inside the sample, external water (water - water test), air (water - air test) and other liquids (water - other liquids
Test) internal pressure resistance test.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 4217 Nominal outside diameter and nominal pressure of thermoplastic pipe for fluid transport (GB/T 4217-2008, ISO 161-1.
1996, IDT)
GB/T 8806 Determination of the dimensions of plastic components for plastic pipe systems (GB/T 8806-2008, ISO 3126.2005, IDT)
GB/T 18252 Plastics piping systems for extrapolation to determine the long-term hydrostatic strength of thermoplastics in the form of pipes
(GB/T 18252-2008, ISO 9080.2003, IDT)
GB/T 18475 Thermoplastics for Pressure Pipes and Fittings Graded and Named Overall Use (Design) Factor
(GB/T 18475-2001, eqvISO 12162.1995)
GB/T 19278-2003 General Terms and Definitions for Thermoplastic Pipes, Fittings and Valves
GB/T 19807 Preparation of plastic pipe and fittings for combination of polyethylene pipe and fused pipe fittings (GB/T 19807-2005,
ISO 11413..1996, MOD)
GB/T 19809 Plastic pipes and fittings Polyethylene (PE) pipes/pipes or pipes/pipes Hot-melt butt joint assemblies
(GB/T 19809-2005, ISO 11414.1996, IDT)
QB/T 2568 solvent-based adhesive for PVC-U plastic pipe systems (QB/T 2568-2002, ASTM D
2564-1996a, MOD)
3 Terms and definitions
The terms and definitions defined in GB/T 19278-2003 and the following apply to this document.
3.1
Component component
A single or combined pipe or valve as a unitary unit.
3.2
Standard size ratio standarddimensionratio
SDR
The ratio of the nominal outside diameter dn of the pipe to the nominal wall thickness en.
[GB/T 19278-2003, definition 6.7]
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 6111-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 6111-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 6111-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 6111-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 6111-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 6111-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|