HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 5590-2024 English PDF

US$639.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 5590-2024: Low voltage explosion protection electromagnetic starter for mining
Status: Valid

GB/T 5590: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 5590-2024English639 Add to Cart 5 days [Need to translate] Low voltage explosion protection electromagnetic starter for mining Valid GB/T 5590-2024
GB/T 5590-2008English529 Add to Cart 4 days [Need to translate] Low voltage explosion protection electromagnetic starter for mining Valid GB/T 5590-2008
GB 5590-1985English479 Add to Cart 4 days [Need to translate] Mining type flameproof electric magnetic starters Obsolete GB 5590-1985

PDF similar to GB/T 5590-2024


Standard similar to GB/T 5590-2024

GB/T 3836.4   GB/T 3836.35   GB/T 3836.8   GB 3836.16   GB 3836.15   

Basic data

Standard ID GB/T 5590-2024 (GB/T5590-2024)
Description (Translated English) Low voltage explosion protection electromagnetic starter for mining
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K35
Word Count Estimation 32,324
Date of Issue 2024-08-23
Date of Implementation 2024-08-23
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 5590-2024: Low voltage explosion protection electromagnetic starter for mining

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Low voltage explosion protection electromagnetic starter for mining Explosion-proof low-voltage electromagnetic starter for mining ICS 29.260.20 CCS K35 National Standard of the People's Republic of China Replaces GB/T 5590-2008 Released on 2024-08-23 2025-03-01 Implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface ... Ⅲ 1 Scope ... 1 2 Normative references ... 1 3 Terms, definitions and symbols ... 2 3.1 Terms and Definitions 2 3.2 Symbols ... 2 4 Classification and naming ... 2 4.1 Classification ... 2 4.2 Naming ... 3 5 Features ... 3 5.1 Rated values and limit values of main circuits 3 5.2 Category of use ... 3 5.3 Control Circuit ... 4 5.4 Auxiliary circuit ... 4 5.5 Protection function ... 4 6 Normal working conditions ... 4 7 Technical Requirements ... 5 7.1 General requirements 5 7.2 Explosion-proof safety requirements ... 5 7.3 Performance Requirements 8 8 Test methods ... 17 8.1 Verification of explosion-proof safety methods 17 8.2 Verification Performance Methods 17 9 Inspection Rules ... 18 9.1 Inspection categories ... 18 9.2 Type inspection ... 18 9.3 Periodic Inspection 19 9.4 Factory Inspection 19 10 Marking, packaging, transportation and storage 21 10.1 Logo 21 10.2 Packaging 22 10.3 Transportation and storage 22 References ... 23

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting is required. This document replaces GB/T 5590-2008 "Explosion-proof low-voltage electromagnetic starter for mining". Compared with GB/T 5590-2008, except for the structure In addition to adjustments and editorial changes, the main technical changes are as follows. Changed the scope (see Chapter 1, Chapter 1 of the.2008 edition); - The terms and definitions of pilot circuits (see 3.1.1 of the.2008 edition) have been deleted; - The provisions on code names have been deleted (see 3.3 of the.2008 edition); - Added the categories of fan starters, flameproof starters, flameproof and intrinsically safe starters, and other explosion-proof starters (see 4.1); Changed the use category requirements (see 5.2, 5.7 of the.2008 edition); - Changed the control circuit requirements (see 5.3, 5.9 of the.2008 edition); - Changed the protection function requirements (see 5.5.2, 6.5 of the.2008 edition); - Changed the mechanical environmental conditions requirements (see Table 2, Table 2 of the.2008 edition); - Added general requirements (see 7.1); - Changed the structural requirements (see 7.2.1, 8.1.1 of the.2008 edition); - The electrical clearance in the main cavity has been changed (see Table 3, Table 3 of the.2008 edition); - Changed the intrinsically safe structure requirements (see 7.2.1.14, 8.1.7 and 8.1.8 of the.2008 edition); - The temperature rise requirements have been changed (see 7.3.1, 8.2.1 of the.2008 edition); - Changed the making and breaking capacity requirements (see 7.3.4, 8.2.4.1 of the.2008 edition); - Changed the no-load operating performance (operating characteristic range) requirements (see 7.3.5.1, 8.2.5.1 of the.2008 edition); - Changed the life requirements (see 7.3.6, 8.2.6 of the.2008 edition); - Changed the requirements for the overload current capability of the contactor (see 7.3.7, 8.2.7 of the.2008 edition); - Added reset mode requirements for overload protection performance, phase failure protection performance, and short circuit protection performance (see Table 17, Table 19, Table 22); Added requirements for starter control functions for fans (see 7.3.15); - Added communication function requirements (see 7.3.22); - The test method has been changed (see Chapter 8, Chapter 9 of the.2008 edition); - Changed the inspection rules (see Chapter 9, Chapter 10 of the.2008 edition). - Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the China Electrical Equipment Industry Association. This document is under the jurisdiction of the National Technical Committee for Standardization of Explosion-proof Electrical Equipment (SAC/TC 9). This document was drafted by. China Coal Technology and Engineering Group Shenyang Research Institute Co., Ltd., Anbiao National Mining Product Safety Marking Center Co., Ltd., Shenyang Electric Drive Research Institute (Co., Ltd.), Nanyang Explosion-proof Electrical Research Institute Co., Ltd., Dianguang Explosion-proof Technology Co., Ltd., Fushun China Coal Technology and Engineering Testing Center Co., Ltd., Shanghai Coal Science Testing Technology Co., Ltd., Huainan Wantai Electronics Co., Ltd., Bada Electric Co., Ltd. Company, Shenyang University of Technology, Nanjing Shuangjing Electric Group Co., Ltd., Shanxi Lu'an Anyi Electric Co., Ltd., Shanxi Ji'an Electric Co., Ltd. Company, Shanxi Huaxin Electric Co., Ltd., Xuzhou Huadong Machinery Co., Ltd., Wuxi Jungong Intelligent Electric Co., Ltd., Nanyang Zhongtong Intelligent Technology Group Co., Ltd., Sany Heavy Equipment Co., Ltd., and Shenyang Guangjiao Complete Electric Co., Ltd. The main drafters of this document are. Qin Yan, Zhang Hongkui, Zhang Yong, Zhu Shian, Chen Fandong, Fan Jianqiang, Hu Jihong, Li Zhongqiang, Liu Daping, Qi Dongqian, Zhang Lixiao, Pan Yanan, Wang Shuai, Li Bin, Yang Guangyu, Chen Qing, Chang Haiying, Zu An, Ni Rui, Wang Yukun, Wang Gang, Qi Wenting, Tong Wenming, Sun Feng, Wang Yanhe, Yuan Ziyun, Xia Jinggang, Zhang Yongzeng, Zhao Xuliang, Zhao Lei, Sun Qiang, Liu Xiaodong, Cai Quan, Fu, X., Fu, X. The previous versions of this document and the documents it replaces are as follows. First published in 1985 as GB 5590-1985; - First revised in.2008;- This is the second revision. - Explosion-proof low-voltage electromagnetic starter for mining

1 Scope

This document specifies the classification and naming, characteristics, normal working conditions and technical requirements of explosion-proof low-voltage electromagnetic starters for mining, and describes the relevant It specifies the corresponding test methods, inspection rules, and requirements for marking, packaging, transportation and storage. This document is applicable to the control of three-phase squirrel cage asynchronous power in coal mines with rated frequency of 50 Hz and voltage of 1 140 V or less. The motor can be started and stopped locally or remotely, reversed and double-speed, and the mining explosion-proof low-voltage electromagnetic starter can protect the motor and related circuits at the same time. Design, manufacture and inspection of starters (hereinafter referred to as “starters”). The provisions of this document concerning overload protection (see 7.3.10 and 8.2.12) do not apply to embedded overheating protection devices installed inside the motor. device.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies. in this document. GB/T 191 Pictorial markings for packaging, storage and transportation GB/T 762 standard current level GB/T 2423.4 Environmental testing for electric and electronic products Part 2.Test methods Test Db. Cyclic damp heat (12 h + 12 h cycle) GB/T 2423.5 Environmental testing Part 2.Test method Test Ea and guidance. Impact GB/T 2423.10 Environmental testing Part 2.Test methods Test Fc. Vibration (sinusoidal) GB/T 2900.18 Electrical terminology Low voltage electrical appliances GB/T 2900.35 Electrical terminology Explosive atmospheres GB/T 3836.1-2021 Explosive atmospheres Part 1.Equipment General requirements GB/T 3836.2-2021 Explosive atmospheres Part 2.Equipment protected by flameproof enclosure "d" GB/T 3836.3-2021 Explosive atmospheres Part 3.Equipment protected by increased safety "e" GB/T 3836.4-2021 Explosive atmospheres Part 4.Equipment protected by intrinsic safety type "i" GB/T 4205 Basic and safety rules for human-machine interface signs and symbols Operating rules GB/T 4208-2017 Enclosure protection degree (IP code) GB/T 10111 Generation of random numbers and their application in product quality sampling inspection GB/T 14048.1-2023 Low-voltage switchgear and controlgear Part 1.General GB/T 14048.4-2020 Low-voltage switchgear and controlgear Part 4﹘1.Contactors and motor starters Electromechanical contactors Contactors and motor starters (including motor protectors) GB/T 14048.5 Low-voltage switchgear and controlgear Part 5﹘1.Control circuit devices and switching elements Electromechanical control circuits Road Electric

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5590-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5590-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5590-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5590-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5590-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5590-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.