US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5584.1-2020: Rectangular copper or aluminium and its alloy wires for electrical purposes - Part 1: General Status: Valid GB/T 5584.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 5584.1-2020 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Rectangular copper or aluminium and its alloy wires for electrical purposes - Part 1: General
| Valid |
GB/T 5584.1-2020
|
| GB/T 5584.1-2009 | English | 759 |
Add to Cart
|
4 days [Need to translate]
|
Rectangular copper or aluminium and its alloy wires for electrical purposes -- Part 1: General
| Obsolete |
GB/T 5584.1-2009
|
| GB/T 5584.1-1985 | English | 719 |
Add to Cart
|
5 days [Need to translate]
|
Rectangular copper or aluminium and its alloy conductors for electrical purposes--part 1: General
| Obsolete |
GB/T 5584.1-1985
|
PDF similar to GB/T 5584.1-2020
Basic data | Standard ID | GB/T 5584.1-2020 (GB/T5584.1-2020) | | Description (Translated English) | Rectangular copper or aluminium and its alloy wires for electrical purposes - Part 1: General | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K11 | | Classification of International Standard | 29.060.10 | | Word Count Estimation | 11,191 | | Date of Issue | 2020-12-14 | | Date of Implementation | 2021-07-01 | | Older Standard (superseded by this standard) | GB/T 5584.1-2009 | | Quoted Standard | GB/T 321; GB/T 2900.10; GB/T 3954; GB/T 5584.2; GB/T 5584.3; GB/T 5584.4; JB/T 8137.1; JB/T 8137.2; JB/T 8137.3; JB/T 8137.4 | | Regulation (derived from) | National Standard Announcement No. 28 of 2020 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration | | Summary | This standard specifies the terms and definitions, codes and representations, cross-sections, materials, dimensions and deviations, mechanical properties, electrical properties, joints, straightness, surface quality, copper, aluminum and its alloy flat wires and copper strips for electrical purposes. Delivery quality, inspection rules, packaging, marking, transportation and storage, etc. This standard applies to the manufacture of electrical machinery, electrical appliances and other equipment windings, installation of power distribution equipment and other electrical copper, aluminum and its alloy flat wires and copper strips. |
GB/T 5584.1-2020: Rectangular copper or aluminium and its alloy wires for electrical purposes - Part 1: General ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Copper, aluminum and its alloy rectangular wires for electrical purposes Part 1: General provisions)
ICS 29:060:10
K11
National Standards of People's Republic of China
Replace GB/T 5584:1-2009
Copper, aluminum and its alloy flat wires for electrical purposes
Part 1: General rules
Part 1:General
2020-12-14 release
2021-07-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Table of contents
Preface Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Code and representation 2
5 Section 3
6 Material 4
7 Dimensions and deviation 4
8 Mechanical properties 6
9 Electrical performance 7
10 Connector 7
11 Straightness 7
12 Surface quality 7
13 Delivery quality 7
14 Inspection rules 7
15 Packaging, labeling and transportation storage 7
Foreword
GB/T 5584 "Copper, Aluminum and Its Alloy Flat Wire for Electrical Engineering" is divided into four parts:
---Part 1: General provisions;
---Part 2: Copper and its alloy flat wire;
---Part 3: Aluminum flat wire;
---Part 4: Copper tape:
This part is Part 1 of GB/T 5584:
This section was drafted in accordance with the rules given in GB/T 1:1-2009:
This part replaces GB/T 5584:1-2009 "Copper, aluminum and its alloy rectangular wires for electrical purposes-Part 1: General provisions", and GB/T 5584:1-
The main technical changes compared to:2009 are as follows:
---Modified the normative references (see Chapter 2, Chapter 2 of the:2009 edition);
---Modified terms and definitions (see Chapter 3, Chapter 3 of the:2009 edition);
---Modified the status code of the flat line (see 4:1, 4:2 of the:2009 edition);
---The cross-sectional shape of the flat wire has been increased (see Chapter 5);
---Modified the size range of the flat wire (see 7:1, 6:1 of the:2009 edition);
--- Deleted Appendix A (see Appendix A of the:2009 edition):
This part was proposed by China Electrical Equipment Industry Association:
This part is under the jurisdiction of the National Bare Wire Standardization Technical Committee (SAC/TC422):
Drafting organizations of this section: Shanghai Cable Research Institute Co:, Ltd:, Shanghai National Cable Testing Center Co:, Ltd:, Chongqing Pigeon Brand Wire and Cable Co:, Ltd:
Company, Zhongtian Alloy Technology Co:, Ltd:, Zhejiang Libo Industrial Co:, Ltd:, Wuxi Tongli Electric Co:, Ltd:, Wuxi Xizhou Electromagnetic
Wire Co:, Ltd:, Shandong Jinyuan Copper Co:, Ltd:, Hangzhou Cable Co:, Ltd:, Shanghai Pudong Wire and Cable (Group) Co:, Ltd:, global
Energy Internet Research Institute Co:, Ltd:
The main drafters of this section: Cai Xichuan, Ding Zhenpei, Zhang Yongjia, Pang Xiaoming, Zhang Da, Xu Gaolei, Zhang Hengguang, Cao Yongyi, Zhao Ruhai, Hu Jianming,
Chen Wei, Zhu Zhixiang, Chen Xin:
The previous versions of the standards replaced by this part are as follows:
---GB/T 5584:1-1985, GB/T 5584:1-2009:
Copper, aluminum and its alloy flat wires for electrical purposes
Part 1: General rules
1 Scope
This part of GB/T 5584 specifies the terms and definitions, codes and representation methods, cut-offs of copper, aluminum and its alloy rectangular wires and copper strips for electrical purposes:
Surface, materials, dimensions and deviations, mechanical properties, electrical properties, joints, straightness, surface quality, delivery quality, inspection rules, packaging, marking and
Transportation preservation, etc:
This section applies to the manufacture of electrical machinery, electrical appliances and other equipment windings, installation of power distribution equipment and other electrical copper, aluminum and alloy flat wires
Copper tape:
2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T 321 priority number and priority number system
GB/T 2900:10 Electrical terminology cable
GB/T 3954 Electrician round aluminum pole
GB/T 5584:2 Copper, aluminum and its alloy rectangular wires for electrical purposes-Part 2: Copper and its alloy rectangular wires
GB/T 5584:3 Copper, aluminum and its alloy rectangular wires for electrical purposes-Part 3: Aluminum rectangular wires
GB/T 5584:4 Copper, aluminum and its alloy rectangular wires for electrical purposes-Part 4: Copper tape
JB/T 8137 (all parts) wire and cable delivery tray
3 Terms and definitions
The following terms and definitions defined in GB/T 2900:10 apply to this document:
3:1
Specification
The size of the conductor is expressed by the nominal size a×b of the narrow side and the wide side:
3:2
Preferredspecification
The preferred specifications:
3:3
Intermediatespecification
Specifications that are allowed but should not be used as much as possible:
3:4
Specificationnotrecommended
Specifications not recommended:
3:5
Straightness
The maximum height of the arc when the arc or non-straight part of any narrow side is in a horizontal state:
|