US$209.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 5561-2012: Surface active agents -- Determination of viscosity and flow properties using a rotational viscometer Status: Valid GB/T 5561: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 5561-2012 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Surface active agents -- Determination of viscosity and flow properties using a rotational viscometer
| Valid |
GB/T 5561-2012
|
| GB/T 5561-1994 | English | 359 |
Add to Cart
|
3 days [Need to translate]
|
Surface active agents--Determination of viscosity and flow properties using a rotational viscometer
| Obsolete |
GB/T 5561-1994
|
| GB 5561-1985 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Surface active agents--Textile auxiliaries--Measurement of viscosity of surface active agents
| Obsolete |
GB 5561-1985
|
PDF similar to GB/T 5561-2012
Basic data | Standard ID | GB/T 5561-2012 (GB/T5561-2012) | | Description (Translated English) | Surface active agents -- Determination of viscosity and flow properties using a rotational viscometer | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G72 | | Classification of International Standard | 71.100.40 | | Word Count Estimation | 9,979 | | Older Standard (superseded by this standard) | GB/T 5561-1994 | | Adopted Standard | ISO 6388-1989, NEQ | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies a measurement system using a coaxial cylinder rotary viscometer to measure non-solid surfactant flow properties. This standard applies to a single or mixed surfactants, also suitable for primary surfactant-containing products. |
GB/T 5561-2012: Surface active agents -- Determination of viscosity and flow properties using a rotational viscometer ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS71.100.40
G72
National Standards of People's Republic of China
Replacing GB/T 5561-1994
Surfactant using a rotary viscometer
Viscosity and flow properties
(ISO 6388. 1989, Surfaceactiveagents-Determination
offlowpropertiesusingarotationalviscometer, NEQ)
Issued on. 2013-08-01 2012-12-31 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard rule according to GB/T 1.1-2009 given draft.
This standard replaces GB/T 5561-1994 "surfactant using a rotary viscometer viscosity and flow properties", and
GB/T 5561-1994 compared to the main changes are as follows.
--- Increasing the foreword;
--- Remove the model and measurement equipment, range and error rotary viscometer (see 6.1,1994 version 5.1).
The standard reference method using redrafted ISO 6388. 1989 "surfactant with a rotary viscometer liquidity" preparation, and
ISO 6388. 1989 is non-equivalent.
The standard proposed by China Petroleum and Chemical Industry Association.
This standard by the National Standardization Technical Committee Chemistry (specialty) surfactant Technical Committee (SAC/TC63/SC8) centralized.
This standard was drafted. Zhejiang Real Technology Co., Ltd., Zhejiang Textile Co., Ltd. mountains.
The main drafters of this standard. Tang Fuwei, Hanyao Jun, Zhang Chenhui, Ye Jin, Xiao Jianlan.
This standard replaces the standards previously issued as follows.
--- GB/T 5561-1985, GB/T 5561-1994.
Surfactant using a rotary viscometer
Viscosity and flow properties
1 Scope
This standard specifies the use of a rotational viscometer with coaxial cylinder measuring system to measure the non-solid surfactant mobility
Qualitative methods.
This standard applies to single or mixed surfactants, also applies to major surfactant-containing products.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1
Viscosity viscosity
Between two parallel planes by fluid shear, in which a plane in its own plane relative to the other plane with a straight line uniform
The resistance generated when the viscosity of the fluid motion is called Newtonian viscosity equation can be used (1) to represent.
η =
(1)
Where.
η --- Viscosity (dynamic);
τ --- shear stress;
The D --- shear rate.
When independent of shear rate and viscosity of the fluid to be measured when, it is considered that the fluid is a Newtonian fluid.
The apparent viscosity of non-Newtonian fluid is a function of shear rate, depending on the thermal hysteresis of the sample in the instrument and rheological lag.
Viscosity is measured in Newton seconds per square meter (N · s/m2) or Pascal seconds (Pa · s).
2.2
Rheological phenomena rheologicalphenomena
Rheological behavior is defined by the shear stress to describe.
Note. The flow pattern of the fluid in Appendix A.
2.2.1
Shear thinning shearthinning
Under isothermal reversible condition, without apparent viscosity with increasing shear rate lag is reduced.
2.2.2
Expandable dilatancy
Reversible under isothermal conditions, the apparent viscosity without a hysteresis with increasing shear rate increases.
2.2.3
The viscosity change with time time-dependentviscosity
Reversible under isothermal conditions, when the size of the shear rate is constant, the apparent viscosity changes with time.
2.2.3.1
Thixotropic thixotropy
Reversible under isothermal conditions, due to the shearing action to reduce the viscosity or consistency of the final value from zero (start of shear moment) (depending on the cut
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 5561-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 5561-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 5561-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 5561-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 5561-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5561-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|