HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 5509-2008 English PDF

US$139.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 5509-2008: Inspection of grain and oils -- Determination of magnetic metals content of flours
Status: Valid

GB/T 5509: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 5509-2008English139 Add to Cart 3 days [Need to translate] Inspection of grain and oils -- Determination of magnetic metals content of flours Valid GB/T 5509-2008
GB/T 5509-1985English199 Add to Cart 2 days [Need to translate] Inspection of grain and oilseeds--Methods for determination of magnetic metals content of flours Obsolete GB/T 5509-1985

PDF similar to GB/T 5509-2008


Standard similar to GB/T 5509-2008

GB/T 5493   GB/T 5526   GB/T 5496   GB/T 5501   GB/T 5518   GB/T 5500   

Basic data

Standard ID GB/T 5509-2008 (GB/T5509-2008)
Description (Translated English) Inspection of grain and oils -- Determination of magnetic metals content of flours
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard X10
Classification of International Standard 67.040
Word Count Estimation 6,655
Date of Issue 2008-11-04
Date of Implementation 2009-01-20
Older Standard (superseded by this standard) GB/T 5509-1985
Quoted Standard GB 5491
Regulation (derived from) National Standard Approval Announcement 2008 No.18 (Total No.131)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the powder metal grain magnetic measurement principle, instruments and appliances, operating procedures and the results of calculations. This standard applies to wheat flour, corn flour grain nutrition powder measuring various food commodities magnetic powder and metal content, rice flour, glutinous rice flour.

GB/T 5509-2008: Inspection of grain and oils -- Determination of magnetic metals content of flours


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inspection of grain and oils. Determination of magnetic metals content of flours ICS 67.040 X10 National Standards of People's Republic of China Replacing GB/T 5509-1985 Inspection of grain Powder magnetic metals determination Posted 2008-11-04 2009-01-20 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard replaces GB/T 5509-1985 "grain and oilseeds test powder magnetic metals assay." This standard and GB/T 5509-1985 main technical differences are as follows. --- Increasing the scope of this standard; --- Canceled a standard method of operation 2.2 "Magnet Law of Attraction"; --- Canceled a standard method of operation of the rinsing solution --- carbon tetrachloride; --- Original standard "magnet suction unit 12kg" to "120 milli-Tesla magnetic induction (mT)"; --- Increased operating method for processing residual sample and the magnetic metal plate separating mixtures by magnet separation; --- Increase in the "evaluation" process sample flow rate through the drip model specified time; --- Original standard formula of "mg/kg" replaced by "g/kg"; --- In the "apparatus and appliances" column adds "separating plate" and its technical parameters; --- In the "apparatus and appliances" column abolition of the "horseshoe magnet" and technical requirements; --- Increase the informative appendix "separation plate schematic" (see Appendix A). Appendix A of this standard is an informative annex. The standard proposed by the National Food Authority. This standard by the National Standardization Technical Committee OILS. This standard is drafted by. National Food Reserve Chengdu Grain Storage Research Institute. Participated in the drafting of this standard. Shanghai Jiading OILS Instruments. The main drafters of this standard. Wangxing Juan, Wang Ke, Zhang Huachang, Zhuang Jian, Xie Xia. This standard replaces the standards previously issued as follows. --- GB/T 5509-1985. Inspection of grain Powder magnetic metals determination

1 Scope

This standard specifies the flour magnetic metal grain measurement principle, apparatus and appliances, and the result of the calculation procedure. This standard applies to wheat flour, rice flour, glutinous rice flour, corn flour and various cereals flour food nutrition powder product-containing magnetic metal Determination of the amount.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB 5491 Inspection of grain oilseeds for sampling, and sample method Principle 3 Electromagnet or permanent magnet to which the magnetic field having a magnetic metal separated from a crude sample, then small permanent magnets The magnetic metal separated from the residue of the sample mixture out to calculate the content of the magnetic metal objects.

4 apparatus and appliances

4.1 magnetic metal detector. magnetic induction strength of not less than 120mT (milli-Tesla). 4.2 Separation plate. 210mm × 210mm × 6mm, a schematic diagram in Appendix A, the magnetic flux density of not less than 120mT. 4.3 Balance. dividing the value of 0.0001g. 4.4 Balance. dividing the value of 1g, the largest weighing more than 1000g. 4.5 Weighing paper. sulfuric acid paper or absorbent paper is not easy. 4.6 White. about 200mm × 300mm. 4.7 brush, large ear wash ball, scoops and other said.

5 steps

5.1 said sample 5.1.1 for sampling and sample decimation performed in GB 5491. 5.1.2 Weigh the sample (m1) 1kg, accurate to 1g from the average sample dispensing. 5.2 Determination 5.2.1 Analyzer separation Open magnetic metal detector (4.1) of the power supply, the sample is poured into a measuring instrument Sheng powder hopper, press through a magnetic switch. Adjust the flow control plate Knob to control the sample flow 250g/min or so, so that the sample uniform by drip into the reservoir model pink box. The sample stream to be finished, wash the ear Balls remaining on the drip template sample powder is blown into the storage tank and then connected with a clean white mobility analyzer model below, through closed magnetic switch, stand That brush with the hair net adsorbed on a magnetic metal mobility model (containing a small amount of the sample), and collected on a place of white paper. 5.2.2 Separation plate separator The collected paper-magnetic metal and the sample mixture remaining in a prepared separation plate (4.2), the hand-pulled two paper

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5509-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5509-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5509-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5509-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5509-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5509-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.