GB/T 44374-2024: Determination of performance of pressurized fluid extractor
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 44374-2024English319 Add to Cart 4 days [Need to translate] Determination of performance of pressurized fluid extractor Valid GB/T 44374-2024

PDF similar to GB/T 44374-2024


Standard similar to GB/T 44374-2024

GB/T 40219   GB/T 30431   GB/T 29476   GB/T 37847   GB/T 37837   

Basic data

Standard ID GB/T 44374-2024 (GB/T44374-2024)
Description (Translated English) Determination of performance of pressurized fluid extractor
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N50
Classification of International Standard 71.040
Word Count Estimation 16,147
Date of Issue 2024-08-23
Date of Implementation 2024-08-23
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 44374-2024: Determination of performance of pressurized fluid extractor

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of performance of pressurized fluid extractor Method for determining the performance of pressurized fluid extractors ICS 71.040 CCS N 50 National Standard of the People's Republic of China Released on 2024-08-23 2024-08-23 implementation State Administration for Market Regulation The National Standardization Administration issued

Table of Contents

Preface ... Ⅲ 1 Scope ... 1 2 Normative references ... 1 3 Terms and Definitions ... 1 4 Reagents and Materials ... 2 5 Instruments and equipment ... 2 6 Determination of performance indicators ... 2 6.1 Measurement conditions 2 6.2 Temperature performance ... 3 6.3 Pressure performance ... 3 6.4 Deviation between extraction solvent delivery channels 4 6.5 Consistency of extraction results 5 6.6 Cross contamination 6 Appendix A (Informative) Schematic diagram of pressurized fluid extraction apparatus ... 7 Appendix B (Normative) Determination of oil content in vegetable oils - pressurized fluid extraction method (taking soybean as an example) ... 8 B.1 Test steps 8 B.2 Result calculation 9

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting is required. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the Ministry of Science and Technology of the People's Republic of China. This document is under the jurisdiction of the National Technical Committee for Standardization of Instrumental Analysis and Testing (SAC/TC 481). This document was drafted by. China Customs Science and Technology Research Center, China Institute of Metrology, Vicoto (Beijing) Technology Co., Ltd. Beijing Haiguang Instrument Co., Ltd., Beijing Labtech Instrument Co., Ltd., Ruike Group (Xiamen) Co., Ltd., Beijing Lindian Weiye Electronic Technology Co., Ltd., Beijing Academy of Agricultural and Forestry Sciences, Beijing Zhongren Testing Technology Service Co., Ltd., Guangxi Zhuang Autonomous Region Radiation Radiation Environment Supervision and Management Station, Beijing Institute of Standardization, and Beijing Miyun District Center for Disease Control and Prevention. The main drafters of this document are. Qiu Ye, Liu Xin, Shi Junwen, Song Dewei, Kong Weiheng, Wang Yikai, Yun Huan, Gao Feng, Jia Wenshen, He Ying, Zhu Tianyu, Song Jialu, Han Shen, Liu Zebin, He Jingming, Li Wenfeng, Jia Yueqin, Yin Xiaobo, Zhang Weiwei, Zhou Jie. Method for determining the performance of pressurized fluid extractors

1 Scope

This document defines the terms and definitions for the performance measurement of pressurized fluid extractors and describes the measurement methods, including reagents and materials, instrumentation and Steps for measuring equipment and performance indicators. This document applies to the temperature performance, pressure performance, extraction solvent delivery channel deviation, extraction result consistency and Determination of cross contamination.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies. in this document. GB/T 6682 Specifications and test methods for water used in analytical laboratories GB/T 14488.1 Determination of oil content in vegetable oils

3 Terms and definitions

The following terms and definitions apply to this document. 3.1 Pressurized fluid extractor A type of pretreatment equipment that uses heated and pressurized extraction solvents to quickly extract organic components from solid and semi-solid samples (see schematic diagram) Figure A.1). Note 1.A pressurized fluid extractor is also called a rapid solvent extractor or an accelerated solvent extractor. Note 2.During the extraction process of the pressurized fluid extractor, the extraction temperature and extraction pressure are the core parameters that affect the extraction results. The set pressure of the extraction cell and its connecting fluid pipes. The extraction temperature refers to the set temperature of the internal heating furnace of the pressurized fluid extractor when extracting samples. 3.2 Heating time After the extraction cell is loaded into the heating furnace, it begins to be filled with the extraction solvent. The time from the completion of the addition of the extraction solvent to the start of the static extraction is measured. 3.3 Temperature balance between extraction cell and heating oven When the pressurized fluid extractor extracts the sample, the temperature inside the extraction cell containing the sample and the extraction solvent reaches equilibrium with the temperature of the heating furnace. process. 3.4 Static extraction time When the pressurized fluid extractor extracts samples, the extraction starts from the end of the heating time, that is, the extraction temperature and pressure reach the set value, until the first extraction The time elapsed until the loop ends. 3.5 Cycles of extraction When a pressurized fluid extractor extracts a sample, the process starts with delivering the extraction solvent (pressurization) and ends with static extraction. NOTE. The number of extraction cycles performed is also called the cycle number.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 44374-2024_English be delivered?

Answer: Upon your order, we will start to translate GB/T 44374-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 44374-2024_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 44374-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.