HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 42125.19-2022 English PDF

US$264.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 42125.19-2022: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 19: Particular requirements for electrically operated valve actuators
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 42125.19-2022English264 Add to Cart 3 days [Need to translate] Safety requirements for electrical equipment for measurement, control and laboratory use - Part 19: Particular requirements for electrically operated valve actuators Valid GB/T 42125.19-2022

PDF similar to GB/T 42125.19-2022


Standard similar to GB/T 42125.19-2022

GB/T 41295.3   GB/T 41295.2   GB/T 41295.4   GB 42125.11   GB/T 42125.18   GB/T 42125.17   

Basic data

Standard ID GB/T 42125.19-2022 (GB/T42125.19-2022)
Description (Translated English) Safety requirements for electrical equipment for measurement, control and laboratory use - Part 19: Particular requirements for electrically operated valve actuators
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard N10
Classification of International Standard 13.110; 17.020; 19.020
Word Count Estimation 14,142
Date of Issue 2022-10-12
Date of Implementation 2023-05-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 42125.19-2022: Safety requirements for electrical equipment for measurement, control and laboratory use - Part 19: Particular requirements for electrically operated valve actuators


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 19.Particular requirements for electrically operated valve actuators ICS 13.110;17.020;19.020 CCSN10 National Standards of People's Republic of China Electrical equipment for measurement, control and laboratory use Safety requirements part 19.electric Particular requirements for control valve actuators 2022-10-12 release 2023-05-01 implementation State Administration for Market Regulation Released by the National Standardization Management Committee

table of contents

Preface III Introduction IV 1 Scope and purpose1 2 Normative references 2 3 Terms and Definitions 2 4 Trial 2 5 Signs and documents 3 6 Protection against electric shock 4 7 Protection against mechanical hazards 4 8 Resistance to mechanical stress4 9 Preventing the spread of flames 5 10 Temperature limits and heat resistance of the device 5 11 Protection against liquid and solid foreign object hazards 5 12 Protection against radiation (including laser sources), acoustic pressure and ultrasonic pressure5 13 Protection against released gases and substances, explosion and implosion5 14 Components and assemblies 5 15 Protection by means of interlocks 6 16 Hazards arising from the application 6 17 Risk assessment 6 Reference 7

foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents" drafting. This document is Part 19 of GB/T 42125 "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use". GB/T 42125 has The following parts have been published. --- Part 10.Particular requirements for insulation resistance measurement and dielectric strength test equipment; --- Part 19.Special requirements for electric control valve actuators. This document is equivalent to IEC 61010-2-202.2020 "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 2-202 Part. Special requirements for electric control valve actuators". The following minimal editorial changes have been made to this document. --- In order to coordinate with existing standards, change the name of the standard to "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 19 Part. Special requirements for electric control valve actuators". Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents. This document is proposed by China Machinery Industry Federation. This document is under the jurisdiction of the National Measurement, Control and Laboratory Electrical Equipment Safety Standardization Technical Committee (SAC/TC338). This document is drafted by. Machinery Industry Instrumentation Comprehensive Technology and Economic Research Institute, Zhejiang Zhongkong Sensing Technology Co., Ltd., China Quality Certification Center, Jiangsu Provincial Institute of Quality and Standardization, Fujian Shangrun Precision Instrument Co., Ltd., Liaoning Provincial Institute of Metrology, China Electronics Technology Standardization Research Institute, Qingdao Metrology Technology Research Institute, Beijing Medical Device Inspection Research Institute, Hangzhou Snow Carbon Constant Temperature Technology Co., Ltd. Division, Shanghai Institute of Metrology and Testing Technology, Anhui Food and Drug Inspection Institute, Shandong Institute of Metrology, Shanghai Industrial Automation Instrument Research Institute Co., Ltd., Hangzhou Yungu Technology Co., Ltd., Fodayway (Shanghai) Industrial Instrument Technology Research and Development Co., Ltd., Rhine Inspection Testing and Certification Service China Co., Ltd., Harbin Institute of Technology Special Robot Co., Ltd., Harbin Institute of Technology Robotics (Yueyang) Military-civilian Integration Research Institute. The main drafters of this document. Shang Yujia, Wang Weimin, Hu Nan, Wang Jing, Feng Xiawei, Ge Jian, Liang Guoding, Liu Xiaojing, Guo Jianyu, Jing Jun, Liang Zhenshi, Xu Yueming, Zhang Yi, Wang Wenli, Ma Xuefeng, Zhang Yixiang, Ding Yun, Wu Lianqun, Mai Miao, Feng Jian, Sun Dahai, Lu Huawei.

Introduction

GB/T 42125 "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use" is proposed to be composed of 20 parts. --- Part 1.General requirements. The purpose is to specify the general safety of electrical equipment and accessories for measurement, control and laboratory use Require. --- Part 2.Particular requirements for laboratory equipment for heating materials. The purpose is to specify the special requirements for heating equipment for laboratory materials security requirements. --- Part 3.Special requirements for refrigeration equipment. The purpose is to specify the special safety of measurement, control and laboratory refrigeration equipment Require. --- Part 4.Special requirements for climate and environmental test equipment and other temperature regulation equipment. The purpose is to regulate the climate and environmental Special safety requirements for environmental testing equipment and other temperature regulating equipment. --- Part 5.Special requirements for laboratory centrifuges. The purpose of this document is to specify specific safety requirements for laboratory centrifuges. --- Part 6.Special requirements for test and measurement circuits. The purpose is to specify special safety requirements for test and measurement circuits. --- Part 7.Safety requirements for hand-held and hand-operated probe assemblies for electrical measurements and tests. The purpose is to specify the hand-held and hand-operated probes Safety requirements for head assemblies and related accessories. --- Part 8.Particular requirements for hand-held and hand-operated current sensors for electrotechnical measurement and testing. The purpose is to stipulate the hand-held and hand-operated Special safety requirements for current sensors. --- Part 9.Particular requirements for household and professional hand-held multimeters capable of measuring grid power supply voltage. The purpose is to specify the measurable Particular safety requirements for household and professional hand-held multimeters for measuring mains supply voltage. --- Part 10.Particular requirements for insulation resistance measurement and dielectric strength test equipment. The purpose is to specify the output voltage AC Safety requirements for equipment used for insulation resistance measurement and dielectric strength test at 50V or above DC 120V. --- Part 11.Special requirements for sterilizers and washer-disinfectors for processing medical materials. The purpose is to regulate the processing of medical materials Special safety requirements for sterilizers and washer-disinfectors. --- Part 12.Special requirements for laboratory mixing and stirring equipment. The purpose is to specify electric Particular safety requirements for laboratory equipment and its accessories. --- Part 13.Special requirements for laboratory thermal atomization and ionization atomic spectrometers. The purpose is to specify laboratory heat Particular safety requirements for atomic spectrometers for atomization and ionization. --- Part 14.Particular requirements for automatic and semi-automatic equipment for laboratory analysis and other purposes. intended for laboratory use Particular safety requirements for automatic and semi-automatic equipment for analytical and other purposes. --- Part 15.Special requirements for cabinet X-ray systems. The purpose is to specify special safety requirements for cabinet-type X-ray systems. --- Part 16.Particular requirements for in vitro diagnostic (IVD) medical devices. The purpose is to specify the intended use for in vitro diagnostic medical purposes Special requirements for medical equipment. --- Part 17.Special requirements for children using equipment in educational institutions. The purpose is to stipulate the use of student operators in educational institutions Special safety requirements for equipment and accessories used. --- Part 18.Special requirements for control equipment. The purpose is to specify the special requirements and related identification test. --- Part 19.Special requirements for electric control valve actuators. intended to be specified for installation in industrial process or discrete control Safety requirements for electric control valve actuators and solenoid coils in the environment. --- Part 20.Special requirements for interconnection of industrial communication circuits and communication ports. intended to specify installations in process or discrete control Particular safety requirements for industrial communication circuits in the environment. Note. All parts are equivalent to the IEC 61010 series standards, and the corresponding relationship is as follows. --- Part 1 corresponds to IEC 61010-1; --- Part 2 corresponds to IEC 61010-2-010; --- Part 3 corresponds to IEC 61010-2-011; --- Part 4 corresponds to IEC 61010-2-012; --- Part 5 corresponds to IEC 61010-2-020; --- Part 6 corresponds to IEC 61010-2-030; --- Part 7 corresponds to IEC 61010-031; --- Part 8 corresponds to IEC 61010-2-032; --- Part 9 corresponds to IEC 61010-2-033; --- Part 10 corresponds to IEC 61010-2-034; --- Part 11 corresponds to IEC 61010-2-040; --- Part 12 corresponds to IEC 61010-2-051; --- Part 13 corresponds to IEC 61010-2-061; --- Part 14 corresponds to IEC 61010-2-081; --- Part 15 corresponds to IEC 61010-2-091; --- Part 16 corresponds to IEC 61010-2-101; --- Part 17 corresponds to IEC 61010-2-130; --- Part 18 corresponds to IEC 61010-2-201; --- Part 19 corresponds to IEC 61010-2-202; --- Part 20 corresponds to IEC 61010-2-203. Common safety terms are defined in IEC 61010-1.More specialized terms are defined elsewhere. This document needs to be combined with IEC 61010-1.2010 AMD1.2016 "Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use Part 1.General Requirements The part of this document that states "applicable" means that the corresponding clauses of IEC 61010-1 apply to this document; this document states "replace" or "modify" The part of "modification" indicates that the terms of this document shall prevail; the part of this document that states "increase" indicates that in addition to complying with the corresponding provisions of IEC 61010-1 In addition to the clauses, the clauses added in this document must also be complied with. In order to distinguish the terms in IEC 61010-1, the number of terms added to this document The number starts with 101, for example 7.3.101. Electrical equipment for measurement, control and laboratory use Safety requirements part 19.electric Particular requirements for control valve actuators

1 Scope and purpose

Except as follows, Chapter 1 of IEC 61010-1 applies. 1.1 Scope 1.1.1 Equipment included in the scope of this document Replace it with the following. This document specifies the safety requirements for electric control valve actuators and solenoid coils intended for installation in industrial process or discrete control environments. Require. This document specifies. --- Special safety requirements for general electric control valve actuators and solenoid coils; --- Relevant identification test. 1.1.2 Equipment not covered by the scope of this document Add after the column item. This document does not cover. aa) Electric actuators and solenoid coils for domestic or commercial use; Note 1.This content is covered by other IEC or ISO standards, such as IEC 60730, etc. bb) electric actuators and solenoid coils performing safety functions; Note 2.This content is covered by other IEC or ISO standards, such as IEC 61058, etc. cc) Locator. Note 3.A positioner is defined in IEC 60050-351.2013, 351-56-17 as "performing additional (usually mechanical) feedback to a mechanical final control element to A physical unit that increases its speed and accuracy". 1.2 Purpose 1.2.2 Aspects not included in the scope of this document Add after the column item. aa) Mechanical components/aspects of the valve. 1.2.101 Aspects covered by other applicable standards If compliance with other IEC or ISO standards is required for electric actuators and solenoid coils, aspects fully covered by these standards may be substituted Requirements given in IEC 61010-1. If the aspects covered by IEC 61010-1 cannot be fully covered by the IEC or ISO standard, the tests of IEC 61010-1 should be carried out to ensure that No hazard occurs under normal conditions or single fault conditions. NOTE. Figure 15 in 14.1 of IEC 61010-1.2010/AMD1.2016 gives an overview of handling components within the scope of other IEC or ISO standards.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 42125.19-2022_English be delivered?

Answer: Upon your order, we will start to translate GB/T 42125.19-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 42125.19-2022_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 42125.19-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.