Basic data | Standard ID | GB/T 41993-2022 (GB/T41993-2022) | | Description (Translated English) | Sound signalling devices for household and similar purposes | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K30 | | Classification of International Standard | 29.120 | | Word Count Estimation | 70,779 | | Date of Issue | 2022-10-12 | | Date of Implementation | 2023-05-01 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 41993-2022: Sound signalling devices for household and similar purposes---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Sound signaling devices for household and similar purposes
ICS 29.120
CCSK30
National Standards of People's Republic of China
Sound signaling devices for household and similar purposes
(IEC 62080.2015, MOD)
Released on 2022-10-12
2023-05-01 implementation
State Administration for Market Regulation
Released by the National Standardization Management Committee
table of contents
Preface III
1 Scope 1
2 Normative references 1
3 Terms and Definitions 6
4 General requirements 10
5 General notes on testing 10
6 categories 11
7 signs 11
8 Protection against electric shock 13
9 Structural Requirements 14
10 Normal operation 17
11 temperature rise 17
12 Abnormal working conditions 21
13 Aging resistance, protection against ingress of solid foreign matter, protection against harmful ingress of water and moisture 22
14 Insulation resistance and electric strength 23
15 Mechanical strength 27
16 heat resistance 30
17 Internal Wiring 31
18 elements 32
19 Terminal 32
20 flexible cable and its connection 32
21 Grounding measures 36
22 Screws, current-carrying parts and their connections 37
23 Creepage distances and clearances 38
24 Resistance to abnormal heat and flame resistance of insulating materials 40
25 Anti-rust performance 41
26 Electromagnetic compatibility (EMC) requirements 41
Appendix A (Normative) Electronic Devices 52
Appendix B (Normative) Electromagnetic Compatibility (EMC) Requirements 54
Appendix C (Normative) Measurement of creepage distance and clearance 58
Reference 62
Figure 1 Examples of different types of screws43
Figure 2 Standard test finger 44
Figure 3 Cover or Cover Plate Test Apparatus 45
Figure 4 Gauges (approximately 2 mm thick) for checking the outline of covers and covers 45
Figure 5 Example 46 of using the gauge of Figure 4 to a cover that is not screwed to a mounting or support surface
Figure 6 Example of using the gauge in Figure 4 as required47
Figure 7 Blank 48
Figure 8 Blank 48
Figure 9 Ball pressure device 48
Figure 10 Bending test device 49
Figure 11 Test pin 50
Figure 12 Test wall 50
Figure 13 Illustration 51
Table 1 Forces applied to covers, cover plates or actuating elements not secured by screws14
Table 2 Torques applied to screws and connections18
Table 3 Maximum temperature rise 19
Table 4a Temperature Limits for Windings 21
Table 4b Temperature Limits for Enclosures, Supply Wires and Wiring 21
Table 5 Minimum insulation resistance values of additional insulation protection devices and grounding protection devices 24
Table 6 Minimum insulation resistance value for installing protective devices 24
Table 7a Test voltage for devices with rated voltage not exceeding 130V25
Table 7b Test voltage for devices with rated voltage exceeding 130V25
Table 8 Test voltage 26
Table 9 Pull force on the pin 28
Table 10 Torque values used to verify the mechanical resistance of threaded glands 29
Table 11 Tensile force and torque 34
Table 12 Minimum Electrical Clearance 38
Table 13a Creepage distances for basic insulation and supplementary insulation 39
Table 13b Creepage distances for reinforced insulation 39
Table B.1 Testing Requirements and Levels for Classification of Electronic Devices by Series 54
foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules for Standardization Documents"
drafting.
This document is modified to adopt IEC 62080.2015 "Sound signaling devices for household and similar purposes".
Compared with IEC 62080.2015, this document has made the following structural adjustments.
---9.2 corresponds to 9.2 and the following suspension sections in IEC 62080.2015;
---13.3.1~13.3.3 respectively correspond to the suspension section of 13.3, 13.3.1 and 13.3.2 in IEC 62080.2015;
---15.1~15.9 respectively correspond to the suspension section and 15.1~15.8 of Chapter 15 in IEC 62080.2015;
---15.6.1~15.6.3 respectively correspond to the suspension section of 15.5, 15.5.1 and 15.5.2 in IEC 62080.2015, add 15.6.1
title;
--- Remove the number corresponding to 22.1 in IEC 62080.2015, because there is no 22.2 in IEC 62080.2015;
---22.1~22.5 respectively correspond to 22.1.1~22.1.5 in IEC 62080.2015;
--- 26.1~26.4 respectively correspond to the suspension section and 26.1~26.3 of Chapter 26 in IEC 62080.2015, adding the title of 26.1;
--- 26.3.1~26.3.7 respectively correspond to the suspension section of 26.2 and 26.2.1~26.2.6 in IEC 62080.2015, add 26.3.1
title;
--- 26.4.1~26.4.5 respectively correspond to the suspension section of 26.3 and 26.3.1~26.3.4 in IEC 62080.2015, add 26.4.1
title;
---A.2.1~A.2.3 respectively correspond to the suspension section of A.2, A.2.1 and A.2.2 in IEC 62080.2015;
--- Remove the number corresponding to A.2.1.1 in IEC 62080.2015, because there is no A.2.1.2 in IEC 62080.2015;
--- A.3.1 corresponds to the title of A.3.1 in IEC 62080.2015;
---A.3.2~A.3.5 corresponds to A.3.1.1~A.3.1.4 in IEC 62080.2015.
The technical differences between this document and IEC 62080.2015 and their reasons are as follows.
--- Added "This document specifies the technical requirements for the structure, mechanical properties and electrical properties of sound signal devices for household and similar purposes.
requirements" to comply with the provisions of GB/T 1.1 (see Chapter 1);
--- Replaced IEC 60068-2-32.1975 with the normatively quoted GB/T 2423.7, which is in line with the actual citations in this document
conditions, in order to adapt to my country's technical conditions and increase operability (see 15.3);
--- Replaced IEC 60068-2-75.1997 with the normatively quoted GB/T 2423.55, which is in line with the actual citations in this document
conditions, in order to adapt to my country's technical conditions and increase operability (see 15.2);
--- Replaced IEC 60112.1979 with the normative referenced GB/T 4207, in line with the actual references in this document, to suit
Adapt to the technical conditions of our country and increase operability (see 23.3);
--- Replaced IEC 60529.1989 with the normative referenced GB/T 4208, in line with the actual references in this document, to suit
Adapt to my country's technical conditions and increase operability (see 6.5, 7.3, 13.2, 13.3.1);
--- Replaced CISPR14 (all parts) with the normatively referenced GB 4343 (all parts), in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.4.2, 26.4.3, Table B.1);
--- Replaced IEC 60245 (all parts) with the normatively referenced GB/T 5013 (all parts), consistent with the actual
The citation situation of the standard, in order to adapt to the technical conditions of our country and increase the operability (see 9.13, 20.3);
--- Replaced IEC 60227 (all parts) with the normatively referenced GB/T 5023 (all parts), consistent with the actual in this document
The citation situation of the standard, in order to adapt to the technical conditions of our country and increase the operability (see 20.3);
--- Replaced IEC 60695-2-1 (all parts) with the normative references GB/T 5169.10, GB/T 5169.11, conforming to the
The actual citations in the document to adapt to the technical conditions of our country and increase operability (see 24.2);
--- Replaced IEC 60417 (all parts) with the normative referenced GB/T 5465.2-2008, consistent with the actual in this document
Citation conditions to adapt to my country's technical conditions and increase operability (see 7.3, 7.4, 7.5);
--- Replaced IEC 60317 (all parts) with the normatively referenced GB/T 6109.1-2008, consistent with the actual in this document
Citation conditions to adapt to my country's technical conditions and increase operability (see Table 12, A.2.2);
--- Replaced IEC 60384-14.1993 with the normative referenced GB/T 6346.14-2015, which conforms to the actual reference in this document
In order to adapt to the technical conditions of our country and increase operability (see A.3.3);
--- Replaced IEC 60065.1998 with the normative referenced GB 8898-2011, in line with the actual references in this document
conditions, in order to adapt to my country's technical conditions and increase operability (see A.2.2, A.3.4);
--- Replaced IEC 60127 (all parts) with the normatively referenced GB/T 9364 (all parts), consistent with the actual
citations to adapt to my country's technical conditions and increase operability (see A.3.2);
--- Replaced ISO 1456.1988 with the normatively quoted GB/T 9797, which conforms to the actual reference situation in this document, to adapt to
my country's technical conditions, increase operability (see 22.5);
--- Replaced ISO 2081.1986 with the normatively quoted GB/T 9799, which conforms to the actual reference situation in this document, to adapt to
my country's technical conditions, increase operability (see 22.5);
--- Replaced IEC 60212.1971 with the normative referenced GB/T 10580, in line with the actual references in this document, to suit
Adapt to the technical conditions of our country and increase operability (see 24.2);
--- Replaced IEC 60085.1984 with the normative referenced GB/T 11021, in line with the actual references in this document, to suit
Adapt to my country's technical conditions and increase operability (see Table 3);
--- Replaced IEC 60216 (all parts) with the normatively referenced GB/T 11026 (all parts), consistent with the actual
citations to adapt to my country's technical conditions and increase operability (see Table 3);
--- Replaced ISO 2093.1986 with the normative referenced GB/T 12599, in line with the actual references in this document, to suit
Adapt to the technical conditions of our country and increase operability (see 22.5);
--- Replaced IEC 60998 (all parts) with the normatively referenced GB/T 13140 (all parts), consistent with the actual
citations to adapt to my country’s technical conditions and increase operability (see Chapter 19);
--- Replaced IEC 60730 (all parts) with the normatively referenced GB/T 14536 (all parts), consistent with the actual
citations to adapt to my country's technical conditions and increase operability (see A.3.5);
--- Replaced IEC 60664-1.1992 with the normative referenced GB/T 16935.1, in line with the actual references in this document
conditions, in order to adapt to my country's technical conditions and increase operability (see 23.1);
--- Replaced IEC 60664-3 with the normative referenced GB/T 16935.3, in line with the actual references in this document, to suit
Adapt to the technical conditions of our country and increase operability (see 23.1);
--- Replaced IEC 60320 (all parts) with the normatively referenced GB/T 17465 (all parts), in line with the actual
The citation situation of the standard, in order to adapt to the technical conditions of our country and increase the operability (see 18.2, 18.3, 20.1);
--- Replaced IEC 60670 (all parts) with the normatively referenced GB/T 17466 (all parts), consistent with the actual
citations to adapt to my country’s technical conditions and increase operability (see Chapter 1, 13.3.2);
--- Replaced IEC 61000-3-2.2000 with the normative referenced GB 17625.1, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.4.4, Table B.1);
--- Replaced IEC 61000-3-3.1994 with the normative referenced GB/T 17625.2, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.4.5, Table B.1);
--- Replaced IEC 61000-4-2.1995 with the normative referenced GB/T 17626.2, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.6, Table B.1);
--- Replaced IEC 61000-4-3.1995 with the normative referenced GB/T 17626.3, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.7, Table B.1);
--- Replaced IEC 61000-4-4.1995 with the normatively quoted GB/T 17626.4, which is in line with the actual citations in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.5, Table B.1);
--- Replaced IEC 61000-4-5.1995 with the normative referenced GB/T 17626.5, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.4, Table B.1);
--- Replaced IEC 61000-4-6.1996 with the normative referenced GB/T 17626.6, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.2, Table B.1);
--- Replaced IEC 61000-4-11.1994 with the normative referenced GB/T 17626.11, in line with the actual references in this document
In order to adapt to the technical conditions of our country and increase operability (see 26.3.3, Table B.1);
--- Replaced IEC 61000-2-2.1990 with the normative referenced GB/T 18039.3, in line with the actual references in this document
conditions, in order to adapt to my country's technical conditions and increase operability (see 26.2);
--- Replaced IEC 61558-1.1997 with the normative referenced GB/T 19212.1, in line with the actual references in this document
In order to adapt to my country's technical conditions and increase operability (see Table 3 and Table 12);
--- Increased the relevant content of the type and size of plug and socket in my country to adapt to the technical conditions of my country and increase operability (see 18.2,
18.3, 18.4);
--- In order to maintain the rigor of the full text, change Figure 8 to "blank".
The following editorial changes have been made to this document.
--- Replaced IEC 60061-3 with informative references to GB/T 1483 (all parts);
--- Replaced IEC 60357 with the informative referenced GB/T 14094;
--- Replaced IEC 61140 (see 3.37) with the informative referenced GB/T 17045-2020;
--- Replaced IEC 60238 with the informative referenced GB/T 17935;
--- Replaced IEC 61184 with the informative referenced GB/T 17936;
--- Replaced IEC 60061-2 with the informative referenced GB/T 19148;
--- Replaced IEC 60838 (all parts) with informative references to GB/T 19651 (all parts).
Please note that some contents of this document may refer to patents. The issuing agency of this document assumes no responsibility for identifying patents.
This document is proposed by China Electrical Equipment Industry Association.
This document is under the jurisdiction of the National Electrical Accessories Standardization Technical Committee (SAC/TC67).
This document is drafted by. China Electric Apparatus Research Institute Co., Ltd., Zhejiang Chint Construction Electric Co., Ltd., Jiangsu Tongling Technology
Co., Ltd., Zhejiang Zhilun Home Furnishing Technology Co., Ltd., Xiamen Yangmai Electric Co., Ltd., Bull Group Co., Ltd., Weikai Testing Technology
Co., Ltd., Schneider Electric (China) Co., Ltd. Shenzhen Branch, Zhejiang Best Electric Co., Ltd., Guangdong Liying Intelligent Technology Co., Ltd.
Division, Guangdong Futian Electric Co., Ltd., Guangdong Liansheng Conduction Technology Co., Ltd., Legrand Intelligent Electric (Huizhou) Co., Ltd., Zhejiang Yuehuadian
News Co., Ltd., China Quality Certification Center, Weihai Honglin Power Technology Co., Ltd., China National Accreditation Center for Conformity Assessment, Shaanxi
Yateni Electronics Co., Ltd., Guangdong Quanwei Industrial Technology Co., Ltd., Shaanxi Juzhong Zhide Electronic Technology Co., Ltd., Yiwu Riqing Household Products
Products Co., Ltd., Fujian Heyu Home Furnishing Technology Co., Ltd., Ningbo Ouzhi Electric Technology Co., Ltd., Shaanxi Faxida Electronics Co., Ltd., Ningbo
Xingxingxing Standard Technology Co., Ltd., Guangdong Yanfei Technology Co., Ltd., Ningbo Cartmark Intelligent Kitchenware Co., Ltd., Xi'an Xumaizhi
Neng Home Appliance Technology Co., Ltd., Ningbo Yahui Intelligent Technology Co., Ltd.
The main drafters of this document. Liu Yang, Liu Chang, Zhang Mei, Chen Bin, Tian Li, Cai Jun, Hu Zhuohuai, Chen Geng, Cheng Han, Gong Zhilei, Liu Yaorong,
Ding Chunyan, Liang Xiqiang, Qiu Hong, Liu Kaixi, Wang Sheng, Liu Shuiqiang, Jia Haifeng, Zhang Hongwen, Yan Hua, Sun Ting, Quan Yongde, Wang Zhewei, Li Shouying,
Ke Cilong, Xiang Ximei, Xiao Benchong, Huang Qiongfang, Ke Jinming, Liu Heping, Xu Hongwei, Chen Feng, Chen Naien.
Sound signaling devices for household and similar purposes
1 Scope
This document specifies the technical requirements for the structure, mechanical properties and electrical properties of sound signaling devices for household and similar purposes.
This document applies to household and similar uses with a rated voltage not exceeding 250Va.c. or 250Vd.c. and with a rated input power not exceeding
100VA sound signaling devices with integral enclosures and intended to be incorporated in enclosures conforming to GB/T 17466 (all parts) or accompanying
Acoustic signaling device provided together with the housing. In these sound signaling devices, it may also include instructions with a rated input power not exceeding 10VA.
lights.
These products are referred to as "devices" in this document.
This document applies to fixed, mobile and plug-in installations for indoor or outdoor use.
In places with special conditions, special structures may be required.
Note 1.This document can be used as a guide for the technical requirements of sound signaling devices with voltages below 50Va.c. or 75Vd.c. voltages under consideration are below
Additional requirements for 50Va.c. or 75Vd.c. sound signaling devices.
Note 2.This document does not contain radio transmission and reception functions.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references
For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
this document.
GB/T 1002 Types, basic parameters and dimensions of single-phase plugs and sockets for household and similar purposes
GB/T 1003 Types, basic parameters and dimensions of three-phase plugs and sockets for household and similar purposes
GB/T 2423.7 Environmental testing Part 2.Test method Test Ec. Shock caused by rough handling (mainly used for equipment type
Sample) (GB/T 2423.7-2018, IEC 60068-2-31.2008, IDT)
GB/T 2423.55 Environmental testing for electric and electronic products - Part 2.Environmental testing Test Eh. Hammer test
(GB/T 2423.55-2006, IEC 60068-2-75.1997, IDT)
GB/T 4207 Method for determination of tracking resistance index and relative tracking index of solid insulating materials (GB/T 4207-2012,
IEC 60112.2009, IDT)
GB/T 4208 Enclosure protection level (IP code) (GB/T 4208-2017, IEC 60529.2013, IDT)
GB 4343 (all parts) Electromagnetic compatibility requirements for household appliances, electric tools and similar appliances [CISPR14 (all parts)]
Note. GB 4343.1 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools and Similar Appliances Part 1.Emission (GB 4343.1-2018, CISPR14-1.
2011, IDT);
GB/T 4343.2 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools and Similar Appliances Part 2.Immunity (GB/T 4343.2-2020,
CISPR14-2.2015, IDT).
GB 4343.1-2018 Electromagnetic Compatibility Requirements for Household Appliances, Electric Tools and Similar Appliances Part 1.Emission (CISPR14-
1.2011, IDT)
GB/T 5013 (all parts) Rubber insulated cables with rated voltages up to and including 450/750V [IEC 60245 (all parts)]
Note. GB/T 5013.1 Rated voltage 450/750V and below rubber insulated cables Part 1.General requirements (GB/T 5013.1-2008,
IEC 60245-1.2003, IDT);
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 41993-2022_English be delivered?Answer: Upon your order, we will start to translate GB/T 41993-2022_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 41993-2022_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 41993-2022_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|