|
US$729.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 40688-2021: Internet of things - Data interface of vital signs sensing devices Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 40688-2021 | English | 729 |
Add to Cart
|
6 days [Need to translate]
|
Internet of things - Data interface of vital signs sensing devices
| Valid |
GB/T 40688-2021
|
PDF similar to GB/T 40688-2021
Basic data | Standard ID | GB/T 40688-2021 (GB/T40688-2021) | | Description (Translated English) | Internet of things - Data interface of vital signs sensing devices | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L78 | | Word Count Estimation | 40,463 | | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 40688-2021: Internet of things - Data interface of vital signs sensing devices---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Internet of things - Data interface of vital signs sensing devices
ICS 35.040
CCSL78
National Standards of People's Republic of China
Data interface of IoT vital signs sensing device
Released on 2021-10-11
2022-05-01 implementation
State Administration for Market Regulation
Issued by the National Standardization Management Committee
Table of contents
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Abbreviations 2
5 General 2
5.1 Communication protocol 2
5.2 Interface description 2
5.3 Coded character set 2
5.4 Data Type 2
6 Interface message format 2
6.1 Request message format 2
6.2 Response message format 3
7 Basic functions and parameters of general interface 4
7.1 Request class interface 4
7.2 Event Push Class Interface 14
8 Basic functions and parameters of service interface 16
8.1 Heart rate category 16
8.2 Blood Pressure 19
8.3 Body temperature category 22
8.4 Respiratory 24
8.5 Blood oxygen saturation class 27
Appendix A (informative) General data interface parameter JSON code example of vital sign sensing equipment 30
Reference 36
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"
Drafting.
Please note that some of the contents of this document may involve patents. The issuing agency of this document is not responsible for identifying patents.
This document was proposed and managed by the National Information Technology Standardization Technical Committee (SAC/TC28).
Drafting organizations of this document. China Electronics Standardization Institute, Beijing Yiwei Network Technology Co., Ltd., Shenzhen Saixi Information Technology Co., Ltd.
Co., Ltd., Beijing Seth Metco Technology Co., Ltd., Shanghai Di Le Husi Health Technology Co., Ltd., Beijing University of Posts and Telecommunications, Shenzhen North Test Testing
Technology Co., Ltd., Anhui Huami Information Technology Co., Ltd., Beijing Shuguang Yitong Technology Co., Ltd., Wuxi Shiling Technology Co., Ltd., China
Institute of Biomedical Engineering, Academy of Medical Sciences, BOE Technology Group Co., Ltd., Xiaomi Communication Technology Co., Ltd., Fuzhou Internet of Things
Open Laboratory Co., Ltd., Institute of Logistics Science and Technology, Academy of Military Sciences, Affiliated Hospital of Jiangnan University, Shandong University
Learned from Qilu Hospital, School of Control Science and Engineering, Shandong University, Jinjiang Huayu Weaving Co., Ltd., Jinjiang City, Fujian Province, Haixi Textile New Material Industrial Technology
Shu Jinjiang Research Institute, Ningxia Internet Medical and Health Standardization Research Co., Ltd., Longteng Semiconductor Co., Ltd., Beijing Yuchengtai Technology
Co., Ltd., Beijing Zhixin Microelectronics Technology Co., Ltd., Chongqing University of Posts and Telecommunications, Suzhou Xunxi Electronic Technology Co., Ltd., Yan'an University Affiliated Medical
Institute, Shandong Institute of Artificial Intelligence, Fujian Dongfang IOT Information Technology Co., Ltd., Hangzhou Yiruilian Technology Co., Ltd.
The main drafters of this document. Liu Qianying, Geng Li, Wang Jianquan, Wang Wenfeng, Yu Hui, Song Jiwei, Zhou Hu, Zhu Jiping, Hong Weijun, Wang Zhiyang,
Li Shiliang, Wang Huaping, Pu Jiangbo, Zhou Yehua, Wang Jin, Du Hui, Du Lei, Jiang Danting, Cheng Wangchi, Lu Zhou, Ma Dedong, Li Wei, Su Chengyu, Zheng Xiaojia,
Zhang Xiangxin, Xu Xichang, Wen Jiangtao, Zhao Dongyan, Li Zhangyong, Zhang Yu, Wang Yinglong, Feng Haiyun, Song Yin, Zheng Dong.
Data interface of IoT vital signs sensing device
1 Scope
This document specifies the general rules and interfaces for the data interface from vital sign sensing equipment to vital sign monitoring system for IoT applications
The message format and the basic functions and parameter requirements of the general interface and business interface.
This document applies to the design, production and use of vital signs sensing devices for IoT applications.
2 Normative references
The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations
Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to
This document.
GB/T 13000-2010 Information Technology Universal Multi-octet Coded Character Set (UCS)
RFC2616 Hypertext Transfer Protocol 1.1 (HypertextTransferProtocol--HTTP/1.1)
RFC4627 JSON Application and Media Type [Theapplication/jsonMediaTypeforJavaScriptObjectNota-
tion(JSON)]
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
Vital signs
An indication used to determine the vital signs of the human body.
Note 1.Vital signs can be measured, and the normal range of indicators varies with race, gender, age, and weight.
Note 2.Including but not limited to five kinds of body temperature, blood pressure, heart rate, respiration and blood oxygen saturation.
3.2
Vital signs sensing device
A device that can obtain vital sign data or an IoT application-oriented device that obtains the status of vital signs based on vital sign data.
Note. Generally have data acquisition, data processing and communication capabilities.
3.3
Vital signs monitoring system vitalsignsmonitoringsystem
Receive, process and store vital sign perception data, and provide vital sign monitoring and management services for individuals, families, medical institutions and other users
The information system can be equipped with vital signs sensing equipment.
3.4
Codecharacterset
A set of clear rules, which establishes a one-to-one correspondence between the character set and the characters in the character set and their bit groups.
[Source. GB/T 1988-1998, 4.6]
3.5
Transaction
The process of communication and interaction between the vital sign sensing device and the vital sign monitoring system.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 40688-2021_English be delivered?Answer: Upon your order, we will start to translate GB/T 40688-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 40688-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 40688-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|