GB/T 38332-2019: Smart grid consumer automatic demand response - Technical condition of central air conditioning system terminal
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 38332-2019English359 Add to Cart 4 days [Need to translate] Smart grid consumer automatic demand response - Technical condition of central air conditioning system terminal Valid GB/T 38332-2019

PDF similar to GB/T 38332-2019


Standard similar to GB/T 38332-2019

GB/T 36050   GB/T 36278   GB/T 33592   GB/T 45527   GB/T 28583   

Basic data

Standard ID GB/T 38332-2019 (GB/T38332-2019)
Description (Translated English) Smart grid consumer automatic demand response - Technical condition of central air conditioning system terminal
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F20
Classification of International Standard 35.200
Word Count Estimation 18,182
Date of Issue 2019-12-10
Date of Implementation 2020-07-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 38332-2019: Smart grid consumer automatic demand response - Technical condition of central air conditioning system terminal


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Smart grid consumer automatic demand response--Technical condition of central air conditioning system terminal ICS 35.200 F20 National Standards of People's Republic of China Smart Grid Users Automatic Demand Response Central air-conditioning system terminal technical conditions 2019-12-10 release 2020-07-01 implementation State Administration of Market Supervision Published by the National Standardization Management Committee

Contents

Foreword III 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Ambient conditions 2 5 Function configuration 2 6 Functional requirements 3 7 Interface requirements 8 8 Performance requirements 9 9 EMC requirements 11 Appendix A (informative appendix) Terminal control strategy operation example and design framework 13

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. Please note that some elements of this document may involve patents. The issuer of this document is not responsible for identifying these patents. This standard was proposed by the China Electric Power Enterprise Federation. This standard is under the jurisdiction of the National Smart Grid User Interface Standardization Technical Committee (SAC/TC549). This standard was drafted. China Electric Power Research Institute Co., Ltd., State Grid Corporation of China, Beijing Huiheshi Technology Co., Ltd. Division, Nanjing Xinlian Electronics Co., Ltd., Yantai Oriental Weston Electric Co., Ltd., Hangzhou Hezhi Electronic Technology Co., Ltd., Jiangsu Lianhong Smart Energy Co., Ltd., Beijing Huaqin Innovation Software Co., Ltd., Beijing Huatong Telecom Technology Co., Ltd., Chengdu Yunshu Environmental Energy Technology Co., Ltd., Shanghai Electric Appliance Research Institute, North China Electric Power University, Southeast University, State Grid Jiangsu Electric Power Co., Ltd., State Grid Zhejiang Electric Power Co., Ltd., State Grid Hebei Electric Power Co., Ltd., State Grid Tianjin Electric Power Company, State Grid Xinjiang Electric Power Co., Ltd., State Grid Shandong Electric Power Company Division, State Grid Jibei Electric Power Co., Ltd., State Grid Anhui Electric Power Co., Ltd., State Grid Materials Co., Ltd. The main drafters of this standard. Chen Songsong, He Sheng, Zhou Hongquan, Li Dezhi, Yan Huaguang, Sun Dinghao, Xie Zunchen, Dong Lijun, Kong Desong, Wu Baocai, Wang Bingyou, Gong Shixiong, Xian Jingrun, Zhang Shaodi, Qin Jian, Tian Shiming, Gong Feixiang, Gao Ciwei, Zhang Xinghua, Yang Bin, Ma Yi, Wang Xin, Liu Qiang, Li Lei, Zhang Kai, Feng Jian, Zhang Haijing, Ma Lei, Zhang Jian, Li Bin, Sun Yi, Sun Beibei, Zhang Haowei, Zuo Songlin, Liu Zhong, Tang Liang, You Jia, Qiu Degui and Wang Lili. Smart Grid Users Automatic Demand Response Central air-conditioning system terminal technical conditions

1 Scope

This standard specifies the environmental conditions, functional configuration, functional requirements, interface requirements, and performance of automatic demand response terminals for centralized air-conditioning systems. Requirements, electromagnetic compatibility requirements. This standard applies to the development and production of automatic demand response terminals for DC 5V ~ 36V and AC 220V/380V centralized air-conditioning systems. Production, testing and maintenance.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. GB/T 9254-2008 Radio disturbance limits and measurement methods for information technology equipment GB/T 17626.2-2018 Electromagnetic compatibility test and measurement technology Electrostatic discharge immunity test GB/T 17626.3-2016 electromagnetic compatibility test and measurement technology radio frequency electromagnetic field radiation immunity test GB/T 17626.4-2018 Electromagnetic compatibility test and measurement technology Electrical fast transient pulse group immunity test GB/T 17626.5-2019 electromagnetic compatibility test and measurement technology surge (impact) immunity test GB/T 17626.6-2017 Electromagnetic compatibility test and measurement technology Radio frequency field induced conducted disturbance immunity GB/T 17626.8-2006 EMC test and measurement technology Power frequency magnetic field immunity test GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology Immunity to voltage sags, short interruptions and voltage changes test GB/T 17626.12-2013 Electromagnetic compatibility test and measurement technology Ring wave immunity test GB/T 32672 General technical specifications for power demand response systems GB/T 35681 Power Demand Response System Functional Specification GB/T 50155 Terminology Standard for Heating Ventilation and Air Conditioning DL/T 1867 Specification for power demand response information exchange JB/T 7249 Terminology of refrigeration equipment

3 terms and definitions

GB/T 32672, GB/T 35681, GB/T 50155, JB/T 7249 and the following terms and definitions apply to this document. 3.1 Demand response terminal Two-way communication with the power system or equipment to achieve data collection, data storage, and control information sending, etc., and can respond to demand Service system (aggregation system) A device for information exchange. 3.2 Demand response strategy Combining the history of the user's power system or equipment with the current electrical parameters and operating status parameters, the demand response service system (aggregation system)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 38332-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 38332-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 38332-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 38332-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.