US$114.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 3810.12-2016: Test methods of ceramic tiles -- Part 12: Determination of frost resistance Status: Valid GB/T 3810.12: Evolution and historical versions
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 3810.12-2016 | English | 114 |
Add to Cart
|
3 days [Need to translate]
|
Test methods of ceramic tiles -- Part 12: Determination of frost resistance
| Valid |
GB/T 3810.12-2016
|
GB/T 3810.12-2006 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Test methods of ceramic tiles -- Part 12: Determination of frost resistance
| Obsolete |
GB/T 3810.12-2006
|
GB/T 3810.12-1999 | English | 239 |
Add to Cart
|
3 days [Need to translate]
|
Test methods of ceramic tiles-- Part 12: Determination of frost resistance
| Obsolete |
GB/T 3810.12-1999
|
PDF similar to GB/T 3810.12-2016
Basic data Standard ID | GB/T 3810.12-2016 (GB/T3810.12-2016) | Description (Translated English) | Test methods of ceramic tiles -- Part 12: Determination of frost resistance | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | Q31 | Classification of International Standard | 91.100.25 | Word Count Estimation | 6,671 | Date of Issue | 2016-04-25 | Date of Implementation | 2017-03-01 | Older Standard (superseded by this standard) | GB/T 3810.12-2006 | Regulation (derived from) | National Standard Announcement No | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 3810.12-2016: Test methods of ceramic tiles -- Part 12: Determination of frost resistance---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Test methods of ceramic tiles - Part 12. Determination of frost resistance
ICS 91.100.25
Q31
National Standards of People's Republic of China
Replace GB/T 3810.12-2006
Test method for ceramic tiles
Part 12. determination of frost resistance
(ISO 10545-12..1995, Ceramictiles-Part 12. Determinationoffrost
resistance, IDT)
2016-04-25 released
2017-03-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Management Committee released
Foreword
GB/T 3810 "ceramic tile test method" is divided into 16 parts.
- Part 1. Sampling and receiving conditions;
- Part 2. Inspection of dimensions and surface quality;
- Part 3. Determination of water absorption, apparent porosity, apparent relative density and bulk density;
- Part 4. Determination of fracture modulus and failure strength;
- Part 5. Determining the impact resistance of a brick with a recovery factor;
- Part 6. Determination of wear depth of unglazed tiles;
- Part 7. Determination of abrasion resistance of glazed tiles;
- Part 8. Determination of linear thermal expansion;
- Part 9. Determination of thermal shock resistance;
- Part 10. Determination of wet expansion;
- Part 11. Determination of glaze resistance of glazed tiles;
- Part 12. Determination of frost resistance;
- Part 13. Determination of resistance to chemical corrosion;
- Part 14. Determination of resistance to contamination;
- Part 15. Determination of lead and cadmium elution of glazed tiles;
- Part 16. Determination of small chromatic aberration.
This part is part 12 of GB/T 3810.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part replaces GB/T 3810.12-2006 "Test methods for ceramic tiles Part 12. Determination of frost resistance". This part with
GB/T 3810.12-2006 compared to the main changes are as follows.
- the formula for calculating the initial water absorption rate E1 (see 5.2, version 5.2 of 5.2);
- modified the temperature requirements (see Chapter 6, Chapter 6 of the.2006 edition);
- modified the final water absorption formula for E2 (see Chapter 6, Chapter 6 of the.2006 edition).
This part uses the translation method equivalent to ISO 10545-12..1995 "Ceramic tiles Part 12. Determination of frost resistance" (English version).
This section makes the following editorial changes.
a) Standard name modified to "Ceramic tile test method Part 12. Determination of frost resistance".
b) Incorporated the contents of the Technical Corrigendum ISO 10545-12..1995/Cor.1..1997 published in.1997, with "less than 0.01%" in 4.2
(60 ± 2.6) kPa "with" (40 ± 2.6) kPa "in 5.1" (see 4.2, 5.1).
This section is proposed by the China Building Materials Federation.
This part of the National Building Sanitary Ceramics Standardization Technical Committee (SAC/TC249) centralized.
This part of the drafting unit. Xianyang Ceramic Research and Design Institute, Hangzhou Nobel Group Co., Ltd., Guangdong Mona Lisa New Materials Group
Ltd., Guangdong Dongpeng Holding Co., Ltd., National Building Sanitary Ceramics Quality Supervision and Inspection Center, Ministry of Industry and Information Technology
Laboratory of quality control technology for ceramic and sanitary products.
The main drafters of this part. Wang Bo, Duan Xianhu, Yang Jifang, Li Ying, Zhang Qikang, Jin Guoting.
This part of the previous version of the standard to replace the release of the situation.
--- GB/T 6955-1986;
--- GB/T 3810.12-1999, GB/T 3810.12-2006.
Test method for ceramic tiles
Part 12. determination of frost resistance
1 Scope
This part of GB/T 3810 specifies the test method for all frost resistance of ceramic tiles used in immersion and freezing conditions.
2 principle
After the ceramic tile is saturated with water, it is circulated between 5 ° C and -5 ° C. The surfaces of the bricks should be subjected to at least 100 freeze-thaw cycles.
3 equipment and materials
3.1 Drying box. can work at a temperature of (110 ± 5) ℃; can also be used to obtain the same test results of microwave, infrared or other dry
system.
3.2 Balance. Accurate to 0.01% of sample mass.
3.3 Vacuum device, vacuum after the injection of water to make the water saturation of the device. vacuum pump vacuum can make the device pressure to (60 ± 4) kPa.
3.4 Freezer. can freeze at least 10 bricks, the minimum area of 0.25m2, and make the brick do not contact each other.
3.5 suede.
3.6 Water. The temperature is maintained at (20 ± 5) ° C.
3.7 thermocouple or other suitable temperature measurement device.
4 sample
4.1 samples
The use of not less than 10 pieces of the whole brick, and its minimum area of 0.25m2, for large size of the brick, in order to be able to load the refrigerator,
Cutting, cutting the sample should be as large as possible. Brick should be no cracks, glaze cracks, pinholes, bumps and other defects. If you have to check with defective bricks
In practice, permanent defects were applied before the test, and the defects were checked after the test.
4.2 Preparation of the sample
The bricks were dried in a (110 ± 5) ° C oven (3.1) to constant weight, ie, the difference between two consecutive weighings per hour was less than 0.1%. recording
The quality of each dry brick (m1).
5 soaked in water
5.1 After the brick is cooled to ambient temperature, the brick is placed vertically in the vacuuming device (3.3) so that the brick and the brick and the brick do not come into contact with the inner wall of the device.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 3810.12-2016_English be delivered?Answer: Upon your order, we will start to translate GB/T 3810.12-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 3810.12-2016_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 3810.12-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 3810.12-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 3810.12-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|