HOME   Cart(3)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 37883-2019 English PDF

US$199.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 37883-2019: Determination of chromium, cadmium, lead and arsenic in water treatment chemicals - Inductively coupled plasma atomic emission spectrometry
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 37883-2019English199 Add to Cart 3 days [Need to translate] Determination of chromium, cadmium, lead and arsenic in water treatment chemicals - Inductively coupled plasma atomic emission spectrometry Valid GB/T 37883-2019

PDF similar to GB/T 37883-2019


Standard similar to GB/T 37883-2019

GB/T 41330   GB/T 37907   GB/T 37906   GB/T 45386.1   GB/T 45131   

Basic data

Standard ID GB/T 37883-2019 (GB/T37883-2019)
Description (Translated English) Determination of chromium, cadmium, lead and arsenic in water treatment chemicals - Inductively coupled plasma atomic emission spectrometry
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard G76
Classification of International Standard 71.040.40
Word Count Estimation 10,126
Date of Issue 2019-08-30
Date of Implementation 2020-07-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 37883-2019: Determination of chromium, cadmium, lead and arsenic in water treatment chemicals - Inductively coupled plasma atomic emission spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of chromium, cadmium, lead and arsenic in water treatment chemicals - Inductively coupled plasma atomic emission spectrometry ICS 71.040.40 G76 National Standards of People's Republic of China Determination of chromium, cadmium, lead and arsenic in water treatment agents Inductively coupled plasma optical emission spectroscopy (ICP-OES) Published on.2019-08-30 2020-07-01 implementation State market supervision and administration China National Standardization Administration issued

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Petroleum and Chemical Industry Federation. This standard is under the jurisdiction of the National Chemical Standardization Technical Committee (SAC/TC63). This standard was drafted. Jiashan Luye Environmental Protection Material Factory, Henan Qingshuiyuan Technology Co., Ltd., CNOOC Tianjin Chemical Research and Design Institute Co., Ltd., Shandong Taihe Water Treatment Technology Co., Ltd., Shenzhen Junnuo Testing Co., Ltd., Srire Environmental Technology Co., Ltd. Division, Chongqing Lanjie Guangshun Water Purification Materials Co., Ltd., Shenzhen Aikelt Testing Co., Ltd., Chongqing University, Tianjin Zhengda Technology Co., Ltd. the company. The main drafters of this standard. Yu Minghua, Wang Zhiqing, Zhuang Aijuan, Yin Guangying, Li Zhicheng, Yang Liuyin, Wei Xiaobing, Liu Tao, Zheng Huaili, Zhang Ningbo, Shao Hongqian, Wang Wei. Determination of chromium, cadmium, lead and arsenic in water treatment agents Inductively coupled plasma optical emission spectroscopy (ICP-OES)

1 Scope

This standard specifies the method for determining the content of chromium, cadmium, lead and arsenic in water treatment agents--inductively coupled plasma atomic emission spectrometry. This standard applies to water treatment agent chromium content 0.00025% ~ 0.01%, cadmium content 0.00025% ~ 0.01%, lead content 0.00025%~0.01%, arsenic content 0.00025%~0.01% range determination.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. Preparation of standard solution for GB/T 602 chemical reagent impurity determination GB/T 6682 Analytical laboratory water specifications and test methods

3 method summary

The sample is atomized into a plasma emission spectrometer and then introduced into the plasma torch by argon gas. Each measured element is in the plasma The torch is gasified, ionized, excited and emits characteristic lines, and the intensity of the characteristic line is detected by the detector. Within a certain concentration range, The concentration of the measured element is proportional to the intensity of its characteristic line, thereby determining the content of the element to be tested in the sample. Use external standard according to the characteristics of the sample The method or standard addition method is used for quantification to determine the content of chromium, cadmium, lead and arsenic in the sample.

4 reagents or materials

Caution - The strong acid used in this standard is corrosive and should be avoided when inhaled or in contact with the skin. Splash on the body should be used immediately Rinse with water and seek medical attention if it is severe. 4.1 Reagents and water used in this standard, unless otherwise specified, should be used with superior grade reagents and secondary water in accordance with GB/T 6682. 4.2 Standard solution of impurities required in the test Prepare or select the commercially available standard solution according to the provisions of GB/T 602. 4.3 Sulfuric acid. 4.4 Nitric acid. 4.5 Nitric acid solution. 1 99. 4.6 Chromium standard stock solution. 1000mg/L. 4.7 Chromium standard solution. 100mg/L. Pipette 10 mL of chromium standard stock solution, place in a 100 mL volumetric flask, dissolve with nitric acid Dilute the solution to the mark and shake well. Or according to GB/T 602. 4.8 Cadmium standard stock solution. 1000mg/L. 4.9 Cadmium standard solution. 100mg/L. Pipette 10 mL of cadmium standard stock solution into a 100 mL volumetric flask and dissolve with nitric acid. Dilute the solution to the mark and shake well. Or according to GB/T 602.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 37883-2019_English be delivered?

Answer: Upon your order, we will start to translate GB/T 37883-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 37883-2019_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 37883-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.