US$359.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 36034-2018: Solid wire electrodes, tubular cored electrodes and electrode/flux combinations for submerged arc welding of high strength steels Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 36034-2018 | English | 359 |
Add to Cart
|
4 days [Need to translate]
|
Solid wire electrodes, tubular cored electrodes and electrode/flux combinations for submerged arc welding of high strength steels
| Valid |
GB/T 36034-2018
|
PDF similar to GB/T 36034-2018
Basic data Standard ID | GB/T 36034-2018 (GB/T36034-2018) | Description (Translated English) | Solid wire electrodes, tubular cored electrodes and electrode/flux combinations for submerged arc welding of high strength steels | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | J33 | Classification of International Standard | 25.160.20 | Word Count Estimation | 18,118 | Date of Issue | 2018-03-15 | Date of Implementation | 2018-10-01 | Issuing agency(ies) | State Administration for Market Regulation, China National Standardization Administration |
GB/T 36034-2018: Solid wire electrodes, tubular cored electrodes and electrode/flux combinations for submerged arc welding of high strength steels ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Solid wire electrodes, tubular cored electrodes and electrode/flux combinations for submerged arc welding of high strength steels
ICS 25.160.20
J33
National Standards of People's Republic of China
High-strength steel solid wire and flux-cored wire for submerged arc welding
Wire - flux combination classification requirements
(ISO 26304.2011,Weldingconsumables-Solidwireelectrodes,tubularcored
Published by.2018-03-15
2018-10-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
China National Standardization Administration released
Directory
Preface I
1 Scope 1
2 Normative references 1
3 Category 1
4 Technical requirements 3
5 Test method 8
6 Retest 11
7 Technical conditions for supply 11
Appendix A (informative) Solid wire model/grade control 12
Appendix B (Informative) Flux Type 14
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the redrafted method to modify the use of ISO 26304.2011 "High-strength steel solid welding wire for welding submerged arc welding, flux cored welding
Wire and Wire/Flux Combination Classification (English version).
This standard compares with ISO 26304.2011 in terms of structure, according to classification, technical requirements, test methods, re-inspection and supply technology
Prepare the pieces.
The technical differences between this standard and ISO 26304.2011 and its causes are as follows.
--- With regard to normative references, this standard has made adjustments with technical differences to adapt to China's technical conditions and adjust the situation.
The focus is reflected in Chapter 2, “Normative References,” and the specific adjustments are as follows.
● Added references GB/T 2650, GB/T 2652 and GB/T 3323;
● Equivalent to the use of international standards GB/T 25777, GB/T 18591 instead of ISO 6847, ISO 13916;
● Replaced with GB/T 3965, GB/T 25774.1, GB/T 25775, and GB/T 25778 modified by adopting international standards
ISO 3690, ISO 15792-1, ISO 544, ISO 14344;
● Delete ISO 80000-1.2009.
--- According to China's actual application, according to GB/T 221-2008 "Steel Product Brand Representation" provided with solid wire
Corresponding metallurgical brand number classification of the model.
---In accordance with the tensile strength range of this standard, GB/T 12470-2003 "Low Alloy Steel Welding Wire and Flux for Submerged Arc Welding" was added.
H08MnMoA, H08Mn2MoA, H08Mn2MoVA, H10Mn2MoA, H10Mn2MoVA, H08CrNi2MoA and
Technical requirements for H10Mn2NiMoCuA 7 grades, according to GB/T 3429-2015 "steel wire rod for welding" will be its metallurgical grade
The classification was modified to H08MnMo, H08Mn2Mo, H08Mn2MoV, H10Mn2Mo, H10Mn2MoV, H08CrNi2Mo and
H10Mn2NiMoCu, model number is SUM3, SUM31, SUM3V, SUM4, SUM4V, SUN3C2M1
And SUN2M2C1.
---According to domestic demand, H15Mn2Ni2CrMo, H08MnCrNiCu and GB/T 3429-2015 have been added
H10MnCrNiCu 3 grades of technical requirements, models were compiled as SUN4C1M31, SUN1C1C and SUNCC1.
--- Diffusion Hydrogen number increased "H2" and "H4" for ease of selection.
---For solid wire and GB/T 5293 "un-alloyed steel and fine-grained steel solid welding wire, flux cored wire and welding wire - flux for submerged arc welding
Combination of classification requirements" consistent wire model, the wire chemical composition requirements in accordance with GB/T 5293 was adjusted.
--- According to GB/T 5293, the name of the chemical composition of the deposited metal of the flux cored wire-flux combination was adjusted.
This standard also made the following editorial changes.
--- The standard name was changed to "High-strength steel solid wire for submerged arc welding, flux cored wire and welding wire - flux combination classification requirements";
--- Added Appendix A solid wire model/grade comparison (informative annex);
--- Added Appendix B flux types (informative annex).
This standard is proposed and managed by the National Welding Standardization Technical Committee (SAC/TC55).
This standard was drafted. Institute of Machinery Science Harbin Welding Research Institute, Kunshan Jingqun Welding Material Technology Co., Ltd., Luoyang Peony welding consumables
Group Co., Ltd., Tianjin Bridge Welding Materials Group Co., Ltd., Zigong Atlantic Welding Wire Products Co., Ltd. and Wuhan Iron Anchor Welding Materials Co., Ltd.
Limited company, Shandong Cable Power Welding Material Co., Ltd.
Drafters of this standard. Song Bei, Tong Tianwang, Chu Jijun, Yang Zhengke, Wang Daliang, Qi Yingtang, Liu Dong, Guan Changyong, Yang Zijia, Ma Qingjun,
Hao Longyu.
High-strength steel solid wire and flux-cored wire for submerged arc welding
Wire - flux combination classification requirements
1 Scope
This standard stipulates the classification, technical requirements, and test methods for the combination of high strength steel solid wire, flux cored wire and wire-flux combination for submerged arc welding.
Re-inspection and supply technical conditions and other content.
This standard applies to submerged arc welding of high-strength steel solid wire classification, and the minimum tensile strength requirements of not less than 590MPa wire -
Flux combination classification requirements.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 2650 welding joint impact test method (GB/T 2650-2008, ISO 9016.2001, IDT)
GB/T 2652 Weld and deposited metal tensile test method (GB/T 2652-2008, ISO 5178.2001, IDT)
GB/T 3323 Metal Fusion Welding Joints Radiography
GB/T 3965 Determination of Diffusion Hydrogen in Deposited Metals (GB/T 3965-2012, ISO 3690.2000, MOD)
GB/T 18591 Measurement Guide for Welding Preheating Temperature, Inter-Road Temperature and Preheating Maintaining Temperature (GB/T 18591-2001,
idtISO 13916.1996)
GB/T 25774.1 Inspection of welding materials - Part 1. Preparation and inspection of mechanical properties of steel, nickel and nickel alloy deposited metals
Inspection (GB/T 25774.1-2010, ISO 15792-1.2000, MOD)
GB/T 25775 welding material supply technical conditions product type, size, tolerances and marks (GB/T 25775-2010,
ISO 544.2003, MOD)
GB/T 25777 welding material deposited metal chemical analysis sample preparation method (GB/T 25777-2010, ISO 6847.2000,
IDT)
GB/T 25778 Welding Material Purchase Guide (GB/T 25778-2010, ISO 14344.2010, MOD)
Category 3
3.1 Solid wire classification
Solid wire types are divided according to chemical composition, in which the letters "SU" indicate solid arc welding of submerged arc welding, "SU" after the numbers and letters
Combinations represent the classification of their chemical composition. See Appendix A for comparison of model/plate numbers between solid wires.
Examples of solid wire models in this standard are as follows.
Example 1.
SUN2M2
Submerged arc welding solid wire
Indicates chemical composition
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 36034-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 36034-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 36034-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 36034-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|