GB/T 35791-2017: Specification for single-phase-to-ground fault feeder selection device based on traveling waves for neutral non-effectively grounded system
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 35791-2017English359 Add to Cart 4 days [Need to translate] Specification for single-phase-to-ground fault feeder selection device based on traveling waves for neutral non-effectively grounded system Valid GB/T 35791-2017

PDF similar to GB/T 35791-2017


Standard similar to GB/T 35791-2017

GB/T 38953   GB/T 37155.2   GB/T 19826   GB/T 45648.1   GB/T 45648.2   

Basic data

Standard ID GB/T 35791-2017 (GB/T35791-2017)
Description (Translated English) Specification for single-phase-to-ground fault feeder selection device based on traveling waves for neutral non-effectively grounded system
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K45
Classification of International Standard 29.240.01
Word Count Estimation 18,181
Date of Issue 2017-12-29
Date of Implementation 2018-07-01
Regulation (derived from) National Standards Bulletin 2017 No. 32
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

GB/T 35791-2017: Specification for single-phase-to-ground fault feeder selection device based on traveling waves for neutral non-effectively grounded system


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specification for single-phase-to-ground fault feeder selection device based on traveling waves for neutral non-grounded system ICS 29.240.01 K45 National Standards of People's Republic of China Neutral point non-effective grounding system single-phase ground fault Traveling wave line selection device technical requirements 2017-12-29 Posted 2018-07-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 technical requirements 2 4.1 Environmental conditions 2 4.2 Rated electrical parameters 3 4.3 Power consumption 3 4.4 The main function of the device 3 4.5 The main technical performance of the device 4 4.6 overload 5 4.7 Insulation performance 5 4.8 resistance to heat and humidity 5 4.9 Mechanical Properties 6 4.10 Electromagnetic compatibility requirements 6 4.11 continuous power requirements 7 4.12 Structure and appearance requirements 8 4.13 Safety Requirements 8 5 test methods 8 5.1 Test conditions 8 5.2 Structure and appearance inspection 8 5.3 Changes in ambient temperature on the performance of the test 8 5.4 Transport, storage temperature limit test environment 8 5.5 power changes on the performance of the test 8 5.6 Power consumption test 8 5.7 device function and technical performance test 8 5.8 overload test 8 5.9 Insulation performance test 9 5.10 resistance to heat and humidity performance test 9 5.11 Vibration test 9 5.12 Impact test 9 5.13 crash test 9 5.14 electromagnetic compatibility test 9 5.15 continuous power test 10 5.16 safety requirements test 10 5.17 Functional test 10 6 Inspection rules 11 6.1 Test classification 11 6.2 factory inspection 11 6.3 type test 11 7 logos, labels and operating instructions 13 7.1 signs and labels 13 7.2 Instructions for use 13 8 packaging, transportation, storage 14 8.1 Packaging 14 8.2 Transport 14 8.3 Storage 14

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard proposed by the China Electrical Equipment Industry Association. This standard by the National Measurement Relay and Protection Equipment Standardization Technical Committee (SAC/TC154) centralized. This standard was drafted unit. Tsinghua University, Xuchang Cape Detection Technology Co., Ltd., Gansu Provincial Power Company Wind Power Technology Center, Nanjing NARI Following Paul Electric Co., Ltd., Beijing Sifang Automation Co., Ltd., State Power Nanjing Automation Co., Ltd., Xu Ji Group Limited Company, China Power Engineering Consultants Group Southwest Electric Power Design Institute Co., Ltd., Beijing Purple Measurement and Control Co., Ltd., State Grid Electric Power Research Institute, State Grid Jiangsu Power Company, Hebei Beheng Electrical Technology Co., Ltd., Schneider Electric (China) Co., Ltd., ABB (China) Co., Ltd. Division, Siemens Power Automation Co., Ltd., State Power NARI Technology Co., Ltd., Beijing Antongni Electronic Technology Co., Ltd., Beijing Heng days Beidou Technology Co., Ltd., Baoding and easy to France Electric Technology Co., Ltd., Hangzhou Huipu Electronic Technology Co., Ltd. Shandong Yamada Power Technology Limited company. The main drafters of this standard. Dongxin Zhou, Zhao Huayun, He Sien, Shi Shen line, Chen Yulin, Gurry, Li Yuping, Liu Xing, Mei Tao, Ge Rong Shang, Wang Yu, Chen Hao, Tian Jianjun, Yao Li, Hu Lei, Wang Fei, Tang Chenghong, Liu Jianmin, Zhang Wei, Li Aifeng, Wu Xiaobing, Du Tao, Zhu Bin. Neutral point non-effective grounding system single-phase ground fault Traveling wave line selection device technical requirements

1 Scope

This standard specifies the neutral point of non-effective grounding system single-phase ground fault traveling wave line selection device requirements, test methods, test rules Then, signs, labels, instructions, packaging, transportation, storage and so on. This standard is applicable to the design, manufacture, testing and application of the traveling wave line selection device for the neutral point non-effective grounding system of 66kV and below.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. General specifications for computerized premises GB/T 2887-2011 GB/T 2900.1 Electrotechnical terminology Basic terms GB/T 2900.49 Electrotechnical terminology Power system protection GB/T 4208-2017 enclosure rating (IP code) Basic test methods for protection and safety automatic devices GB/T 7261-2016 Computerized site safety requirements GB/T 9361-2011 GB/T 9969-2008 General instructions for use of industrial products GB/T 11287-2000 Electrical relays - Part 21. Vibration, shock, bump and earthquakes of measuring relays and protection devices Test Part 1. Vibration test (sine) Technical specifications for relay protection and safety automatic devices Shock and collision tests for measuring relays and protection equipment Measuring relays and protection equipment - Part 1. General requirements GB/T 14598.2-2011 GB/T 14598.26-2015 Measuring relays and protection equipment - Part 26. EMC requirements GB/T 14598.27-2008 Measuring relays and protection equipment - Part 27. Product safety requirements DL/T 667 Telecontrol equipment and systems Part 5. Transmission protocol Part 103. Relay equipment Information Interface supporting standards DL/T 860 (all parts) Substation communication networks and systems

3 Terms and definitions

GB/T 2900.1 and GB/T 2900.49 defined by the following terms and definitions apply to this document. 3.1 Neutral grounding system neutralgroundingmodeinpowerdistributionsystem Neutral power distribution system effectively grounded and non-effective grounding in two ways. 3.2 Neutral effective way of grounding neutraleffectivelygrounded The neutral point is directly grounded, grounded via a small resistor or grounded via a small reactance.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 35791-2017_English be delivered?

Answer: Upon your order, we will start to translate GB/T 35791-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 35791-2017_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 35791-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.