US$319.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 34873-2017: Vacuum gauges -- Calibration by direct comparison with a reference gauge Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 34873-2017 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
Vacuum gauges -- Calibration by direct comparison with a reference gauge
| Valid |
GB/T 34873-2017
|
PDF similar to GB/T 34873-2017
Basic data | Standard ID | GB/T 34873-2017 (GB/T34873-2017) | | Description (Translated English) | Vacuum gauges -- Calibration by direct comparison with a reference gauge | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | J78 | | Classification of International Standard | 23.160 | | Word Count Estimation | 16,157 | | Date of Issue | 2017-11-01 | | Date of Implementation | 2018-05-01 | | Regulation (derived from) | National Standard Announcement 2017 No. 29 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 34873-2017: Vacuum gauges -- Calibration by direct comparison with a reference gauge---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Vacuum gauges-Calibration by direct comparison with a reference gauge
ICS 23.160
J78
National Standards of People's Republic of China
The vacuum gauge is compared directly with a standard vacuum gauge
(ISO 3567.2011, IDT)
Posted.2017-11-01
2018-05-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 symbols and abbreviations 3
5 General 3
6 Requirements 4
6.1 Calibration Room Design 4
6.2 vacuum gauge and calibration room to connect the pipeline 5
6.3 Vacuum and air intake system 5
6.4 Calibration gas 5
6.5 Thermometer and indoor conditions 5
6.6 standard vacuum gauge 6
7 Calibration 6
7.1 Step 6
7.2 Measurement results evaluation 7
7.3 Measurement Uncertainty 7
8 calibration certificate 8
Appendix A (Informative) Example of a Possible Calibration System 10
Appendix B (Informative) Problems in Actual Calibration 11
Reference 13
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard uses the translation method identical with ISO 3567.2011 "vacuum gauge and standard vacuum gauge direct comparison and calibration."
This standard is proposed by the China Machinery Industry Federation.
This standard by the National Vacuum Technology Standardization Technical Committee (SAC/TC18) centralized.
This standard drafting unit. China Aerospace Science and Technology Corporation Fifth Institute of the five hundred and eleven Institute, China Institute of Metrology, Hefei
Zhihai Optoelectronics Technology Co., Ltd., Zhejiang Vacuum Equipment Group Co., Ltd., Hunan Weigang Magnetic Fluid Co., Ltd., Beijing North instrument innovation really
Empty technology limited liability company, Dongguan Jin Sheng Precision Components Co., Ltd., Shenyang Institute of Vacuum Technology.
The main drafters of this standard.Li Detian, Xi Zhenhua, Cheng Yongjun, Zhao Lan, Sun Wenjun, Yu Hongyan, Wang Jinkuo, Liu Lei, Wang Xilong, Zhong Yunhui,
After the spring, Wang Gong, Hou Ronghua, Wang Hongxue, Wang Changming, Zhang Wei, Dong Meng, Mei-Ru, Chen Lian, Wang Lingling.
The vacuum gauge is compared directly with a standard vacuum gauge
1 Scope
This standard specifies the vacuum gauge and the standard vacuum gauge directly compare the calibration to meet the physical, technical and measurement conditions. Pass on these bars
The description of the piece can deduce the design of a device that can be used to calibrate a vacuum gauge.
School vacuum gauge can be any type. Many types of gauges consist of several sections, primarily. gauges, cables, instrumentation, and communications
No. read the instrument. This whole part can be regarded as a unit to be calibrated. Thus, if only regulatory (ie, the vacuum gauge is directly exposed to true
Empty part of the environment) to calibrate, then you can record all the settings and conditions, so that the regulation of the user can use and calibration
Measure in the same way.
The standard vacuum gauge is also a calibrated vacuum gauge that is traceable to vacuum primary or national standards (usually) with a compliance
GB/T 27025-2008 calibration certificate required or traceable to the SI system and can determine the measurement uncertainty of absolute measurement instruments
(A few cases).
This standard on how to deal with a special type of vacuum gauge did not guide, whether it is standard vacuum gauge or gauge, such guidance will be in
Available in other standards.
The calibration pressure range discussed in this standard depends on the actual design of the calibration device and the type of standard vacuum gauge. Calibration range at
10-6Pa ~ 110kPa between the changes.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 27025-2008 General Requirements for Testing and Calibration Laboratory Capabilities (ISO /IEC 17025.2005, IDT)
ISO /IEC Guide 98-3, Measurement Uncertainty Part 3. Guidance on Measurement Uncertainty (GUM.1995) [Uncer-
taintyofmeasurement-Part 3.Guidetotheexpressionofuncertaintyin measurement (GUM.
1995)]
3 Terms and definitions
The following terms and definitions apply to this document.
3.1
The original standard primarystandard
Measurement standards established using a primary reference measurement procedure.
See ISO /IEC Guide 99.2007, 5.4, as amended.
3.2
National standard nationalstandard
By the national authority certification, in a country or economy as the same amount of other measurement standards set value measurement standards.
[See ISO /IEC Guide 99.2007, 5.3]
3.3
Referencestandard
Specify the measurement standard used to calibrate other measurement standards of the same type in the designated organization or designated area.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 34873-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 34873-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 34873-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 34873-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|