GB/T 31840.2-2015: Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) -- Part 2: Cables for rated voltages from 6 kV (Um=7.2 kV) up to 30 kV (Um=36 kV)
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 31840.2-2015English1079 Add to Cart 8 days [Need to translate] Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) -- Part 2: Cables for rated voltages from 6 kV (Um=7.2 kV) up to 30 kV (Um=36 kV) Valid GB/T 31840.2-2015

PDF similar to GB/T 31840.2-2015


Standard similar to GB/T 31840.2-2015

GB/T 31489.4   GB/T 33594   GB/T 32129   GB/T 29631   GB/T 31834   GB/T 31840.1   

Basic data

Standard ID GB/T 31840.2-2015 (GB/T31840.2-2015)
Description (Translated English) Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) -- Part 2: Cables for rated voltages from 6 kV (Um=7.2 kV) up to 30 kV (Um=36 kV)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K13
Classification of International Standard 29.060.20
Word Count Estimation 51,581
Date of Issue 2015-07-03
Date of Implementation 2016-02-01
Quoted Standard GB/T 156; GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.13-2008; GB/T 2951.14-2008; GB/T 2951.21-2008; GB/T 2951.31-2008; GB/T 2951.32-2008; GB/T 2951.41-2008; GB/T 3048.4; GB/T 3048.10; GB/T 3048.12; GB/T 3048.13; GB/T 3956-2008; GB/T 4909.2-2009; GB/T 4909.3; GB/T 4909.5; GB/T 6995.3; GB/T 7999; GB/T 9327; GB/T 11091; GB/T 12706.2-2008; GB/T 16927.1; GB/T 18380.12; GB/T 18380.35; GB/T 20975.10; GB/T 20975.11; GB/T 20975.1; GB/T 20975.12; GB/T 20975.13; GB/T 20975.14; GB/T 20975.15; GB/T 20975.16; GB/T 20975.17; GB/T 20975.18; GB/T 20975.19; GB/T 20975.20; GB/T 20975.21; GB/T 20975.2; GB/T 20975.22; GB/T 20975.23; GB/T 20975.24; GB/T 20975.25; GB/T 20975.26; GB/T 20975.3; GB/T 20975.4; GB/T 20975.5; GB/T 20975.6; GB/T 20975.7; GB/T 20975.8; GB/T 20975.9; GB/T 30552-2014; GB/T 31840.1-2015; JB/T 8137.1; JB/T 8996; YB/T 024; ISO 48; IEC 60229-2007; IEC 60986; JB/T 8137.2; JB/T 8137.3; JB/T 8137.4
Regulation (derived from) National Standard Announcement 2015 No.22
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the distribution network for industrial or apparatus, fixed installations rated voltage 6 kV (Um = 7.2 kV) to 30 kV (Um = 36 kV) Aluminum alloy core power cables with extruded insulation material, structure, size and testing requirements. This Standard applies to the rated voltage of 6 kV (Um = 7.2kV) to 30 kV (Um = 36 kV) alloy conductor extruded insulation power cables. In determining cable applications, it is recommended to consider possible risk of radial water. This Standard includes the so-called watertight structure cables and test. This Standard does not include special cable installation and operating conditions, for example in overhead cables, mining industry, nuclear power plants (containment and vicinity), as well as for underwater cable or a ship.

GB/T 31840.2-2015: Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) -- Part 2: Cables for rated voltages from 6 kV (Um=7.2 kV) up to 30 kV (Um=36 kV)



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um = 1.2 kV) up to 35 kV (Um = 40.5 kV) Part 2. Cables for rated voltages from 6 kV (Um = 7.2 kV) up to 30 kV (Um = 36 kV) ICS 29.060.20 K13 National Standards of People's Republic of China Rated voltage 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) Aluminum alloy core power cables with extruded insulation Part 2. Rated voltage 6kV (Um = 7.2kV) To 30kV (Um = 36kV) cable voltagesfrom1kV (Um = 1.2kV) upto35kV (Um = 40.5kV) - Part 2. Cablesforratedvoltagesfrom6kV (Um = 7.2kV) upto 30kV (Um = 36kV) Issued on. 2016-02-01 2015-07-03 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 voltage and labeling materials 2 5 conductor 4 6 Insulation 5 7 shield 6 8 core cable three-core cables, inner liner and filling 7 The metal layer 9, single or three-core cable 8 10 metallic shield 8 11 concentric conductor 9 12 metal armor 9 13 outer sheath 11 14 test conditions 12 15 Routine tests 12 16 sampling test 14 17 electrical type test 17 18 21 Non-electrical type test After the installation of electrical test 19 26 Supplementary Terms 2720 cable products Appendix A (normative) aluminum alloy conductor component 33 Appendix B (normative) aluminum alloy metal shield with the technical requirements 34 Annex C (normative) Interlocking Armored with an aluminum alloy with the technical requirements 36 Annex D (normative) Calculation method to determine the assumptions sheath size 37 Appendix E (normative) rounding off 41 Annex F (normative) Interlocking Armored special performance test 42 Supplementary Provisions Annex G (normative) cable products 44

Foreword

GB/T 31840 "rated voltage 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) Aluminum alloy core power cables with extruded insulation" It is divided into three parts. --- Part 1. Rated voltage 1kV (Um = 1.2kV) and 3kV (Um = 3.6kV) cable; --- Part 2. Rated voltage 6kV (Um = 7.2kV) to 30kV (Um = 36kV) cable; --- Part 3. Rated voltage 35kV (Um = 40.5kV) cable. This section GB/T Part of 231,840. This section drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents. This section is proposed and managed by the China Electricity Council. This part mainly drafted by. Anhui Cable Co., Ltd. welcomes the intention. Participated in the preparation of this section. China Electric Power Research Institute, Beijing power company State Grid Maintenance Company, State Grid Power Company in Jiangsu Province Nanjing Power Supply Company, State Grid Electric Power Research Institute in Zhejiang Province Electric Power Company, Hebei Cable Co., Ltd. Tak-ho, Jiangsu Hengtong Power Cable Co. The company, Gold Electrical Co., Ltd., Anhui Pacific Cable Group Co., Zonta Cable Co., Ltd. Hebei New Baofeng Wire & Cable Ltd., the crown Cable Co., Ltd. Jiangsu-intensity energy transmission lines Technology Co., Ltd. The main drafters of this section. Quqi Yong, Dengxian Bo, Huang Heming, Wang Guangming, Wu Mingxiang, Monschau new, Wu Jian Province, Qian Zi Ming, Yang Zhiqiang, Lvfa Zhong, Jiangjian Qiu, Zhu Pengfei, Zhou Junmin. Rated voltage 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) Aluminum alloy core power cables with extruded insulation Part 2. Rated voltage 6kV (Um = 7.2kV) To 30kV (Um = 36kV) cable

1 Scope

This section GB/T 31840 requirements for industrial distribution network or device, fixed installation rated voltage 6kV (Um = 7.2kV) To 30kV (Um = 36kV) Aluminum alloy core power cables with extruded insulation material, structure, size and test requirements. This section applies to the rated voltage 6kV (Um = 7.2kV) to 30kV (Um = 36kV) alloy conductor extruded insulation power cables. In determining cable applications, it is recommended to consider possible risk of radial water. This section includes the so-called cable and watertight structure test. This section does not include special cable installation and operating conditions, for example in overhead cables, mining industry, nuclear power plants (containment and its attachment Near), as well as for underwater cables or ship.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 156 standard voltage GB/T 2951.11-2008 and optical cables - Common test methods for insulating and sheathing materials Part 11. General test method Measurement of thickness and overall dimensions of mechanical tests GB/T 2951.12-2008 and optical cables - Common test methods for insulating and sheathing materials Part 12. General test method Thermal aging methods GB/T 2951.13-2008 and optical cables - Common test methods for insulating and sheathing materials - Part 13. General test method Density Determination of water absorption tests - Shrinkage test GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test method Low temperature test GB/T 2951.21-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 21. elastomeric compounds designed Ozone resistance test Hot set test - Mineral oil immersion test Test Method GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Methods specific high temperature pressure test for resistance to cracking GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture Methods specific weight loss test - Thermal stability test GB/T 2951.41-2008 cable and the cable Common test methods for insulating and sheathing materials Part 41. polyethylene and polypropylene Mixed Methods specific environmental stress cracking resistance test method for measuring the melt index measured the direct combustion of carbon black and polyethylene (Or) mineral filler content of thermal gravimetric analysis (TGA) measurements of carbon black content microscopy assessment of carbon black dispersion in polyethylene GB/T 3048.4 wire and cable electrical performance test methods - Part 4. Conductor DC resistance test

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 31840.2-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 31840.2-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 31840.2-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 31840.2-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.