Hand-held radiation monitor for detection, alarming and identification of radioactive material
| Valid |
GB/T 31837-2015
|
PDF similar to GB/T 31837-2015
Basic data | Standard ID | GB/T 31837-2015 (GB/T31837-2015) | | Description (Translated English) | Hand-held radiation monitor for detection, alarming and identification of radioactive material | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F84 | | Classification of International Standard | 13.280 | | Word Count Estimation | 23,289 | | Date of Issue | 2015-07-03 | | Date of Implementation | 2016-02-01 | | Quoted Standard | GB 4208-2008; GB/T 4835.1-2012; GB/T 4960.6-2008; GB/T 12162.1-2000; GB/T 16511-1996; ISO 22188-2003 | | Adopted Standard | IEC 62327-2006, MOD | | Regulation (derived from) | National Standard Announcement 2015 No.22 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies requirements for detection, alarm and handheld monitor to identify radioactive material (�� spectrometer), especially for detectors, multi-channel analyzer, recognition software, the radionuclide libraries and monitor display requirements. It also specifies the general characteristics, general test methods, radiation characteristics and electrical properties, mechanical properties, safety features and environmental characteristics. This Standard also for the selection of the appropriate radionuclide library (including at border crossings frequently detected radioactive materials) provide guidance. This Standard is applicable to the detection and identification of radionuclides and can be indicative of �� radiation ambient dose equivalent rate handheld monitor. This Standard does not apply to GB /T 4835.1-2012 covered by radiation protection monitor performance. This Standard relates to the monitor can be used for ISO 22188: 2003 specified purpose. This can be used to design non-standard monitor neutron detection function, this time, the neutron detection requirements do not apply. This Standard does not include high-resolution �� spectrometer laboratory use. Taking into account the possible use of this standard monitor frontline law enforcement officers are not usually experts in radiation protection, which requires a user-friendly monitor the design and operation of a high degree of inherent safety. |
GB/T 31837-2015: Hand-held radiation monitor for detection, alarming and identification of radioactive material ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Hand-held radiation monitor for detection, alarming and identification of radioactive material
ICS 13.280
F84
National Standards of People's Republic of China
For detection, alarm and identification of radioactive materials
Hand-held radiation monitor
Hand-heldradiationmonitorfordetection, alarmingand
(IEC 62327.2006, Radiationprotectioninstrumentation-Hand-held
radiation, MOD)
Issued on. 2016-02-01 2015-07-03 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
General characteristics 3 4
4.1 Overview 3
4.2 radiation detector 3
4.3 Energy calibration 3
4.4 Software 3
3 4.5 User Interface
4.6 Communication Interface 3
4.7 moisture and dust 3
4.8 Flag 4
4.9 Battery status indication 4
4.10 4 switch protection
4.11 Spectrum storage and display 4
4.12 ambient dose equivalent rate indication 4
5 5 General test methods
Pilot 5.1 5
5.2 Reference conditions and standard test conditions 5
5.3 statistical fluctuation 5
6 6 radionuclide identification
6.1 Radionuclide Category 6
6.2 Identification of individual radionuclides 6
6.3 Identification mixed radionuclide 7
Overload characteristics 7 6.4 Recognition
6.5 Source Indicator 7
7 ambient dose equivalent rate indication 8
7.1 Relative intrinsic error 8
7.2 alarm and response time of 8
7.3 overload characteristics indicative of ambient dose equivalent rate 8
8 neutron detector 8
8.1 Neutron instructions 8
8.2 presence of γ neutron radiation directions 9
9 9 electrical and environmental performance requirements
9.1 Settling Time 9
9.2 Power - Battery 9
10 9.3 Vibration
9.4 Mechanical Shock 10
9.5 10 dust and moisture
9.6 Ambient Temperature Effect 11
9.7 Temperature Shock 11
9.8 Relative humidity 12
9.9 Electromagnetic Compatibility 12
9.10 Transport and storage 14
10 File 14
10.1 Certificate 14
10.2 Operation and Maintenance Manual 14
1411 induction test
Appendix A (informative) This standard and IEC 62327.2006 technical differences and their causes 16
References 18
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
2006 "Radiation protection equipment for the detection and identification of radionuclides and. The IEC 62327 Standard is a modified method to use to redraft
Indicates photon radiation ambient dose equivalent rate handheld monitor. "
This standard and IEC 62327.2006 as compared to the presence of a technical difference, Appendix A gives the corresponding technical differences and their reasons for a
Lanbiao.
This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized.
This standard was drafted. Institute of Chemical Defense Institute of the PLA Second.
The main drafters of this standard. Shaw cloudless, Liang Weiping, Li Jinglun, Wang Shanqiang, Yixian Yun, Shizhi Lan, Ma Xinhua.
For detection, alarm and identification of radioactive materials
Hand-held radiation monitor
1 Scope
This standard specifies requirements for detection, alarm and handheld monitor to identify radioactive material (γ spectrometer), and especially for detection
, Multi-channel analyzer, identification software, the radionuclide libraries and monitor display requirements. It also specifies the general characteristics, general test side
, Radiation characteristics and electrical characteristics, mechanical characteristics, security features and environmental characteristics.
This standard also for the selection of the appropriate radionuclide library (including at border crossings frequently detected radioactive materials) provided
guide.
This standard is applicable to the detection and identification of radionuclides and can be indicative of γ radiation ambient dose equivalent rate handheld monitor. This standard does not
Radiation protection monitors the performance of GB/T 4835.1-2012 covered apply.
This standard relates to the monitor can be used for ISO 22188.2003 specified purpose.
This standard can be used to design non-monitor neutron detection function, this time, neutron detection requirements do not apply.
This standard does not include high-resolution γ spectrometer laboratory use.
Taking into account the possible use of this standard monitor frontline law enforcement officers are not usually experts in radiation protection, which requires user-friendly
The monitor design and operation of a high degree of inherent safety.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT)
GB/T 4835.1-2012 radiation protection instrumentation β, X and γ radiation surrounding and/or directional dose equivalent (rate) meters and/or monitors
Part 1. Portable workplace and environmental meters and monitors (IEC 60846-1.2009, IDT)
GB/T 4960.6-2008 nuclear science and technology terminology Part 6. Nuclear instrumentation (IEC 60050-393.2003, IEC 60050-
394.2007, NEQ)
X and γ GB/T 12162.1-2000 for calibrating dosemeters and dose rate meters and for determining their response reference radiation first
Part I. Radiation characteristics and production method (ISO 4037-1.1996, IDT)
GB/T 16511-1996 Electrical and electronic measuring equipment - Documentation (IEC 61187.1993, IDT)
ISO 22188.2003 inadvertent movement and monitoring of illegal traffic of radioactive materials (Monitoringforinadvertent
movementandilicittraffickingofradioactivematerial)
3 Terms and Definitions
GB/T 4960.6-2008 defined and the following terms and definitions apply to this document.
3.1
Normal mode routinemode
By trained non-expert mode of operation used by the user. Including the detection and identification of radionuclides and indicating the ambient dose equivalent rate
Level.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31837-2015_English be delivered?Answer: Upon your order, we will start to translate GB/T 31837-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 31837-2015_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31837-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|