HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (25 Oct 2025)

GB/T 31835-2015 English PDF

US$379.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 31835-2015: Pocket-type personal radiation devices (PRD) for detection and alarming of radioactive material
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 31835-2015English379 Add to Cart 3 days [Need to translate] Pocket-type personal radiation devices (PRD) for detection and alarming of radioactive material Valid GB/T 31835-2015

PDF similar to GB/T 31835-2015


Standard similar to GB/T 31835-2015

GB/T 13286   NB/T 20318   GB/T 24247   GB/T 31837   GB/T 31836   

Basic data

Standard ID GB/T 31835-2015 (GB/T31835-2015)
Description (Translated English) Pocket-type personal radiation devices (PRD) for detection and alarming of radioactive material
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard F84
Classification of International Standard 13.280
Word Count Estimation 18,151
Date of Issue 2015-07-03
Date of Implementation 2016-02-01
Quoted Standard GB 4208-2008; GB/T 4835.1-2012; GB/T 4960.6-2008; GB/T 12162.1-2000; GB/T 12162.2-2004; GB/T 12162.3-2004; GB/T 14055.1-2008; GB/T 14055.2-2012; GB/T 17626.2-2006; GB/T 17626.3-2006; IEC 61526-2010; ISO 8529-3-1998
Adopted Standard IEC 62401-2007, MOD
Regulation (derived from) National Standard Announcement 2015 No.22
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the alarm designed to detect radioactive materials and personal pocket radiometer (PRD), functional criteria, performance requirements and test methods. This Standard applies to the body worn pocket-sized personal radiation meter. PRD for detecting and indicating through ionizing radiation (including photons and/or neutrons) the presence and approximate magnitude, alert the user significantly higher than the average background level radioactive sources exist, but not for providing a dose equivalent rate measuring. This Standard does not apply to GB /T 4835.1-2012, IEC 61526: performance relates to radiation protection instrumentation 2010. When the PRD for other conditions not worn on the human body, its relevant neutron performance may be degraded.

GB/T 31835-2015: Pocket-type personal radiation devices (PRD) for detection and alarming of radioactive material


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Pocket-type personal radiation devices (PRD) for detection and alarming of radioactive material ICS 13.280 F84 National Standards of People's Republic of China For radioactivity detection and alarm Material personal pocket radiometer Pocket-typepersonalradiationdevices (PRD) fordetectionand (IEC 62401.2007, Radiationprotectioninstrumentation- Alarmingpersonalradiationdevices (PRD) for detectionofilicittraffickingofradioactivematerial, MOD) Issued on. 2015-07-03 2016-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions, quantities and units 2 3.1 Terms and definitions 2 3.2 Quantities and Units 3 4 4 design requirements 4.1 General requirements 4 4.2 Mechanical Requirements 4 4.3 Electromagnetic claim 5 5 5 Performance Test 5.1 General test conditions 5 5.2 Radiation Test 6 8 5.3 Environmental Testing 5.4 Mechanical tests 10 5.5 Electrical Test 11 6 file 12 12 6.1 Type test report 6.2 Certificate 12 6.3 Operation and Maintenance Manual 12 Table 1 Reference conditions and standard test conditions 12 Table 2 overall performance requirements 13

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard uses redrafted law revision adopted IEC 62401.2007 "Radiation protection instrumentation used to detect the illegal transport of radioactive material Personal radiation alarm device. " For ease of use, the standard of IEC 62401.2007 made the following technical and editorial changes. --- Standard name changed to "for the detection and alarm of radioactive material personal pocket radiometer"; --- Deleting Introduction; --- Increase in "2 Normative references" in GB/T 4835.1-2012 and IEC 61526.2010, with GB/T 4960.6- 2008 instead of IEC 60050-393.2003 and IEC 60050-394.2007; --- Increasing the term "pocket-sized personal radiation meter" "nuclear material" "radioactive material" "radioactive materials" in "3 Terms and definitions" and "Reference conditions" and its definition; the standard term in a logical order and re-order categories, the "reference device" to "Radiometer reference point", "false positives" in the "false positive rate" for the notes, delete the unused standard terminology, such as "amount The conventional true value "" means "" effective range "" read "" standard deviation, "" routine testing "" acceptance test "" variance "and so on; --- 4.2.1 "radiometer overall size (not including clips, clamping device or external alarm) should not exceed the length of 200mm, width 100mm and a thickness of 50mm "words" radiometer overall size (not including clips, clamping device or external alarm) should not exceed Long 150mm, width 80mm and thickness of 30mm "; --- Description column item 4.2.3 a) and b) to 4.2.3.1 and 4.2.3.2; --- 5.2.3.1 and 5.2.3.2 column item description a) and b) to read 5.2.3.1.1,5.2.3.1.2 and 5.2.3.2.1,5.2.3.2.2; --- 5.3.1.2 suspended following paragraph to 5.3.1.2.1 "Overview" column Item Description a) and b) to 5.3.1.2.2 and 5.3.1.2.3; --- Delete the contents of 6.1; --- Because references GB/T 4835.1-2012 and IEC 61526.2010 "1" and the reference to the two criteria Included in the "2 Normative references", so delete reference. This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized. This standard was drafted. Institute of Chemical Defense Institute of the PLA Second. The main drafters of this standard. Shao Hui, Li Zhiyuan, Hujun Li, Cui Hui, Fan Haijun, Shao Jianhui, Liu. For radioactivity detection and alarm Material personal pocket radiometer

1 Scope

This standard specifies the alarm designed to detect radioactive materials and personal pocket radiometer (PRD), functional standards, to performance Sum test methods. This standard applies to the body worn pocket-sized personal radiation meter. PRD for detecting and indicating through ionizing radiation (including photons and / Or neutron) the presence and approximate magnitude, alert the user of the presence of radioactive sources was significantly higher than the local average background level, but not for providing agent Measurement equivalent rate. This standard does not apply to GB/T 4835.1-2012, IEC 61526. performance relates to radiation protection instrumentation 2010. When the PRD for other conditions not worn on the human body, its relevant neutron performance may be degraded.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 4208-2008 housing protection (IP Code) (IEC 60529.2001, IDT) GB/T 4835.1-2012 radiation protection instrumentation β, X and γ radiation surrounding and/or directional dose equivalent (rate) meters and/or monitors Part 1. Portable workplace and environmental meters and monitors (IEC 60846-1.2009, IDT) GB/T 4960.6-2008 nuclear science and technology terminology Part 6. Nuclear instrumentation (IEC 60050-393.2003, IEC 60050- 394.2007, NEQ) X and γ GB/T 12162.1-2000 for calibrating dosemeters and dose rate meters and for determining their response reference radiation first Part I. Radiation characteristics and production method (ISO 4037-1.1996, IDT) X and γ GB/T 12162.2-2004 for calibrating dosemeters and dose rate meters and for determining their response reference radiation 2 Parts. the energy range of radiation protection is 80keV ~ 1.3MeV and 4MeV ~ 9MeV reference radiation dosimetry (ISO 4037-2.1997, IDT) GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response of X and γ reference radiations 3 Part I. Effect of calibration and measurement of energy and angular response of dosimeters and workplace personal dosimeter (ISO 4037-3.1999, IDT) GB/T 14055.1-2008 neutron reference radiation - Part 1. Radiation characteristics and production method (ISO 8529-1.2001, IDT) GB/T 14055.2-2012 neutron reference radiation - Part 2. Characterization of the radiation field associated with a substantial amount of radiation protection instrumentation calibration Basis (ISO 8529-2.2000, IDT) GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test (IEC 61000-4-2.2001, IDT) GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test (IEC 61000-4- 3.2002, IDT) IEC 61526.2010 Radiation protection instruments to measure X, γ, and β neutron radiation personal dose equivalent Hp (10) and Hp (0.07) Direct reading personal dose equivalent meter (Radiationprotectioninstrumentation-Measurementofpersonaldoseequiva- lentsHp (10) andHp (0,07) forX, gamma, neutronandbetaradiations-Directreadingpersonal doseequivalentmeters)

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 31835-2015_English be delivered?

Answer: Upon your order, we will start to translate GB/T 31835-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 31835-2015_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 31835-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.