US$509.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 31237-2014: Inspection specification for 1 000 kV power system protection relay and automation device Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 31237-2014 | English | 509 |
Add to Cart
|
4 days [Need to translate]
|
Inspection specification for 1 000 kV power system protection relay and automation device
| Valid |
GB/T 31237-2014
|
PDF similar to GB/T 31237-2014
Basic data | Standard ID | GB/T 31237-2014 (GB/T31237-2014) | | Description (Translated English) | Inspection specification for 1 000 kV power system protection relay and automation device | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K45 | | Classification of International Standard | 29.240.10 | | Word Count Estimation | 22,276 | | Quoted Standard | GB/T 2422; GB/T 2900.1; GB/T 2900.17; GB/T 2900.49; GB/T 4365-2003; GB/T 7261-2008; GB/T 7268-2005; GB/T 11287-2000; GB/T 14537-1993; GB/T 14598.3-2006; GB/T 14598.9-2010; GB/T 14598.10-2012; GB/T 14598.13-2008; GB/T 14598.14-2010; GB/T 14598.16-2002; GB/ | | Regulation (derived from) | People's Republic of China Announcement of Newly Approved National Standards 2014 No. 22 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the technical conditions detected 1 000 kV power system protection devices and automatic safety devices, test items, technical requirements, test methods and test results to determine the method. This standard applies to the basic |
GB/T 31237-2014: Inspection specification for 1 000 kV power system protection relay and automation device ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inspection specification for 1 000 kV power system protection relay and automation device
ICS 29.240.10
K45
National Standards of People's Republic of China
1000kV protection devices and systems
Automatic safety device detects technical specifications
Issued on. 2014-09-30
2015-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 detects the condition 2
5 structure and appearance inspection 2
6 Power consumption test 3
7 Environmental Test 3
8 Power Effect Test 4
9 mechanical performance test 4
10 Insulation Test 5
11 Electromagnetic compatibility 6
12 overload test 9
13 measuring element accuracy and functionality means 9
Dynamic simulation test 14 10
Appendix A (normative appendix) 1000kV model test model typical wiring and parameter 15
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Electricity Council.
The standard by the China Electricity Council.
Drafting of this standard. National Grid Corporation, China Electric Power Research Institute, Nanjing NARI-RELAYS Electric Co./State grid Nanjing
Automation Research Institute, Ltd. Xu relay, Beijing Sifang Automation Co., Ltd., Guodian Nanjing Automation Co.,
the company.
The main drafters of this standard. Wang Delin, Zhouchun Xia, Yi Shuyun, Xin Zhou Ze, Liu Hongtao, T. was, ya Dai Xu, Li Ruisheng, Huang Shaofeng,
Wang Feng, Li Bin.
1000kV protection devices and systems
Automatic safety device detects technical specifications
1 Scope
This standard specifies the technical conditions 1000kV detecting power system protection devices and automatic safety devices, testing projects, technology
Requirements, test methods and the method of determining the test results.
This standard applies to the basic method of power system protection testing department and the development department should be followed in carrying out type tests.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2422 electric and electronic products environmental testing terminology
GB/T 2900.1 Electrotechnical Basic terminology
GB/T 2900.17 Electrotechnical terminology of electrical relays
GB/T 2900.49 Electrotechnical terminology - Power System Protection
GB/T 4365-2003 Electrotechnical terminology Electromagnetic Compatibility
Basic testing method GB/T 7261-2008 and relay protection devices
GB/T 7268-2005 secondary circuit of power system control and protection devices with plug and plug-in panel box basic size series
GB/T 11287-2000 Electrical relays - Part 21. Measuring relays and protection equipment vibration, shock, bump and seismic
Tests a vibration test (sinusoidal)
GB/T 14537-1993 and measure impact crash tests relays and protection equipment
GB/T 14598.3-2006 Electrical relays - Part 5. Measuring relays and protection equipment insulation coordination requirements and tests
GB/T 14598.9-2010 metric Part 22-3 relays and protection equipment. Electrical disturbance tests --- radiated electromagnetic field disturbance
test
GB/T 14598.10-2012 Electrical relays - Part 22-4. Electrical disturbance tests - Electrical fast transient/burst immunity
test
GB/T 14598.13-2008 Electrical relays - Part 22-1. Electrical disturbance test for measuring relays and protection equipment
Mortem 1MHz burst immunity test
GB/T 14598.14-2010 metric Part 22-2 relays and protection equipment. Electrical disturbance tests - Electrostatic discharge tests ---
GB/T 14598.16-2002 Electrical relays - Part 25. Electrical relays for measuring relays and protection equipment electromagnetic emissions
test
GB/T 14598.17-2005 Electrical relays - Part 22-6. Electrical relays and protection equipment disturbance tests ---
RF field induced immunity to conducted disturbances
GB/T 14598.18-2012 measuring relays and protection equipment - Part 22-5. Electrical disturbance tests - Surge immunity test
GB/T 14598.19-2007 Electrical relays - Part 22-7. Electrical measuring relays and protection equipment disturbance tests ---
Power frequency immunity tests
GB/T 14598.20-2007 Electrical relays - Part 26. Electromagnetic compatibility requirements for measuring relays and protection equipment
GB 14598.27-2008 metric Part 27 relays and protection equipment. Product safety requirements
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 31237-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 31237-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 31237-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 31237-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|