US$559.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30842-2014: Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30842-2014 | English | 559 |
Add to Cart
|
5 days [Need to translate]
|
Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures
| Valid |
GB/T 30842-2014
|
PDF similar to GB/T 30842-2014
Basic data | Standard ID | GB/T 30842-2014 (GB/T30842-2014) | | Description (Translated English) | Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L06 | | Classification of International Standard | 33.100 | | Word Count Estimation | 24,238 | | Date of Issue | 6/24/2014 | | Date of Implementation | 1/22/2015 | | Quoted Standard | GB/T 4365; DL/T 475 | | Regulation (derived from) | National Standards Bulletin No. 14 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the internal 10 kHz ~ 3 GHz frequency range of the high-pressure chamber shielding effectiveness test requirements and methods of measurement. Also be extended to the frequency of 10 GHz. This standard applies to the evaluation and |
GB/T 30842-2014: Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electromagnetic shielding effectiveness specification and measuring method for high voltage testing enclosures
ICS 33.100
L06
National Standards of People's Republic of China
High voltage test chamber electromagnetic shielding effectiveness
Requirements and methods of measurement
Issued on. 2014-06-24
2015-01-22 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 high voltage test chamber shielding effectiveness in claim 1
4.1 Category 1 high voltage test chamber
4.2 high-pressure test chamber shielding effectiveness in claim 1
4.3 high voltage test chamber insulation resistance, grounding resistance requirements 3
5 General requirements 3
5.1 Measurement Environmental Requirements 3
5.2 Measurement equipment and antennas 3
5.3 Measurement frequency 4
5.4 Calculation of shielding effectiveness 5
Shielding effectiveness 6 high voltage test chamber measuring 6
6.1 measured high voltage test chamber claim 6
6.2 high-pressure test chamber shielding effectiveness measurement method 6
6.3 high voltage electric field shielding attenuation measurement laboratory 14
6.4 measurements determined 14
Requirements and measurement methods in Appendix A (normative) high-voltage test chamber insulation resistance, grounding resistance 15
Annex B (informative) high-voltage electric field shielding attenuation measurement laboratory 17
Annex C (informative) on high voltage test chamber 19 Description Classification
References 20
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The EMC standard by the National Standardization Technical Committee (SAC/TC246) and focal points.
This standard was drafted. China Aerospace Science and Industry Corporation II Hospital 2 ○-three, China Electric Power Research Institute, Changzhou New District Leader of electrons
Ltd., Changzhou City, the Great Wall shielded room Equipment Co., Ltd., a long screen (Beijing) Technology Co., Ltd. electromagnetic protection.
The main drafters of this standard. Wu Hongsen, Wu Hung, Shen Tao, Zhang Jiangong, Han Yufeng, Li Ni, Li Zhizhen, Lele Zhou, Cai Pengfei, Xu Guoying.
High voltage test chamber electromagnetic shielding effectiveness
Requirements and methods of measurement
1 Scope
This standard specifies the internal 10kHz ~ 3GHz frequency range of high voltage test chamber shielding effectiveness requirements and methods of measurement. Frequency can be expanded
Exhibition to 10GHz.
This standard applies to the evaluation and measurement of high voltage laboratory electromagnetic shielding effectiveness.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 4365 Electrotechnical terminology Electromagnetic Compatibility
DL/T 475 grounding device parameter measurement guidelines
3 Terms and Definitions
GB/T 4365 defined by the following terms and definitions apply to this document.
3.1
Shielding effectiveness shieldingeffectiveness
To shield electromagnetic wave isolation or limit the ability of the measure. Usually expressed as a ratio of the magnitude of the incident and transmitted wave, expressed in decibels.
3.2
High voltage test chamber highvoltagetestingenclosure
High voltage test chamber is an electromagnetic shield with facilities specially designed for high-voltage power equipment testing.
3.3
High-voltage laboratory test area testingareaofhighvoltagetestingenclosure
High voltage test chamber for placing the device under test and the test region.
4 high voltage test chamber shielding effectiveness requirements
4.1 Classification high voltage test chamber
High voltage test chamber is divided into four categories according to use, classification described in Appendix C.
4.2 high-pressure test chamber shielding effectiveness requirements
High voltage test chamber shielding effectiveness requirements of Table 1.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30842-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30842-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30842-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30842-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|