HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 30840-2014 English PDF

US$299.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30840-2014: Basic specifications for gas-fired bell furnace for annealing
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30840-2014English299 Add to Cart 3 days [Need to translate] Basic specifications for gas-fired bell furnace for annealing Valid GB/T 30840-2014

PDF similar to GB/T 30840-2014


Standard similar to GB/T 30840-2014

GB/T 37752.1   GB/T 5959.41   GB/T 31137   GB/T 30839.48   GB/T 30839.47   GB/T 30839.21   

Basic data

Standard ID GB/T 30840-2014 (GB/T30840-2014)
Description (Translated English) Basic specifications for gas-fired bell furnace for annealing
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K61
Classification of International Standard 25.180.10
Word Count Estimation 13,147
Date of Issue 6/24/2014
Date of Implementation 1/22/2015
Quoted Standard GB/T 2900.23-2008; GB/T 10066.4-2004; GB/T 10067.1-2005; GB/T 10067.4-2005; GB/T 20115.1-2006; GB/T 20116.1-2006; JB/T 8195.11-2007; JB/T 9691-1999
Regulation (derived from) National Standards Bulletin No. 14 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the gas annealing furnace products (hereinafter referred to as "hood-type furnace") classification, general technical requirements, test methods, inspection rules and grading, marking, transportation, storage and ordering and deliv

GB/T 30840-2014: Basic specifications for gas-fired bell furnace for annealing

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Basic specifications for gas-fired bell furnace for annealing ICS 25.180.10 K61 National Standards of People's Republic of China Gas annealing furnace basic technical conditions Issued on. 2014-06-24 2015-01-22 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Product Category 2 4.1 2 varieties and specifications 4.2 Part 2 4.3 The main parameters 2 5 Technical requirements 3 5.1 General Requirements 3 5.2 pairs of complementary design and manufacture of claim 3 5.3 Performance Requirements 5 5.4 sets requirements 6 6 Test methods 7 6.1 General requirements 7 Measuring 6.2 degrees of temperature uniformity 7 6.3 surface temperature measurement 7 6.4 Test run 7 loading 7 inspection rules and grading 7 8 signs, packaging, transportation and storage 9 9 9 Ordering and Delivery

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Electric Equipment Industry Standardization Technical Committee (SAC/TC121) centralized. This standard was drafted. Harbin Songjiang Electric Furnace Co., Ltd., Xi'an Institute Ltd. furnace, furnace National Quality Supervision Inspection Center. The main drafters of this standard. Qiu, Huangkui Gang, Zhu Lin. Gas annealing furnace basic technical conditions

1 Scope

This standard specifies the gas annealing furnace products (hereinafter referred to as "hood-type furnace") classification, general technical requirements, test methods, inspection regulations And the grading, marking, transportation, storage and ordering and delivery and so on. This standard applies to the design by 4.1, 5.1 and 5.2, it is used mainly for steel or copper-based alloy in a protective atmosphere coils, wire roll, etc. Cover annealing furnace. This standard also applies to similar bell furnace, the different parts can be otherwise.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2900.23-2008 Electrotechnical terminology industrial electric equipment GB/T 10066.4-2004 Test methods for electric equipment - Part 4. Indirect resistance furnaces GB/T 10067.1-2005 basic technical conditions for electric devices - Part 1. General section GB/T 10067.4-2005 Electric equipment basic technical conditions - Part 4. Indirect resistance furnaces GB/T 20115.1-2006 heating fuel in the basic technical conditions - Part 1. General section GB/T 20116.1-2006 Test methods for heating fuel - Part 1. General requirements JB/T 8195.11-2007 Indirect resistance furnaces - Part 11. RB series of bell-type furnace JB/T 9691-1999 Heating Equipment Model methodology

3 Terms and Definitions

GB/T 2900.23-2008, JB/T 8195.11-2007 defined and the following terms and definitions apply to this document. 3.1 Furnaces furnacebase Stove furnaceplatform Located at the bottom of the hood-type furnace used to carry equipment and charge mounted stove circulation fan and deflector of furnace components. 3.2 Master thermocouple maincontrolingthermocouple From the bottom of the hood-type furnace seat introduced, the furnace is located inside the tank, the tank for controlling furnace temperature with thermocouples. 3.3 Monitoring thermocouple monitoringthermocouple From the bell furnace heating mantle sidewall introduced lining located between the inner wall of the vessel and for monitoring the temperature with a heating mantle thermocouple. 3.4 Operating temperature workingtemperature Provisions designed to cover furnace normal temperature, a temperature range. Gas furnace cover refers to the temperature of the furnace tank.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30840-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30840-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30840-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30840-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.