HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 30839.41-2014 English PDF

US$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30839.41-2014: Energy consumption grading for industrial electroheat installations -- Part 41: Pusher resistance heating unit
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30839.41-2014English209 Add to Cart 3 days [Need to translate] Energy consumption grading for industrial electroheat installations -- Part 41: Pusher resistance heating unit Valid GB/T 30839.41-2014

PDF similar to GB/T 30839.41-2014


Standard similar to GB/T 30839.41-2014

GB/T 37752.1   GB/T 5959.41   GB/T 31137   GB/T 30839.48   GB/T 30839.47   GB/T 30839.34   

Basic data

Standard ID GB/T 30839.41-2014 (GB/T30839.41-2014)
Description (Translated English) Energy consumption grading for industrial electroheat installations -- Part 41: Pusher resistance heating unit
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K61
Classification of International Standard 25.180.10
Word Count Estimation 9,956
Date of Issue 9/3/2014
Date of Implementation 2/1/2015
Quoted Standard GB/T 2900.23-2008; GB/T 10066.1-2004; GB/T 10066.4-2004; GB/T 13324-2006
Regulation (derived from) People's Republic of China Announcement of Newly Approved National Standards No. 21 of 2014
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This Standard specifies the scope of various types of energy to push-type resistance heating units, energy parameters, indicators and energy consumption classification determination. This section applies to a natural atmosphere furnace atmosphere and cont

GB/T 30839.41-2014: Energy consumption grading for industrial electroheat installations -- Part 41: Pusher resistance heating unit


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Energy consumption grading for industrial electroheat installations Part 41.. Pusher resistance heating unit ICS 25.180.10 K61 National Standards of People's Republic of China Industrial electric energy classification means Part 41. Push resistance heating unit Part 41. Pusherresistanceheatingunit Issued on. 2014-09-03 2015-02-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 energy range 1 5 2 energy parameters 6 energy parameter index and classification 2 6.1 Push unit furnace unit power consumption (power consumption with comparable units represented) 2 6.2 Push furnace air furnace air furnace loss and loss ratio 2 6.3 Push furnace surface temperature furnace 3 7 Energy Consumption Parameter Test Method 3 7.1 General Requirements 3 7.2 Test Conditions 3 7.3 comparable unit power consumption measuring 3 7.4 Push furnace air furnace air furnace loss and loss ratio test 5 7.5 Push furnace surface temperature measurements 5

Foreword

GB/T 30839 "Industrial electric energy classification means" existing five sections. --- Part 1. Common part; --- Part 31. IF coreless induction furnace; --- Part 32. voltage-frequency multi-station frequency coreless induction furnace complete sets of equipment; --- Part 4. Indirect resistance furnaces; --- Part 41. Push resistance heating unit. We will continue to develop other parts as needed. This section GB/T 30839 Part 41 shall be the first and Part 4 for use. This section drafted in accordance with GB/T 1.1-2009 given rules. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Electric Equipment Industry Standardization Technical Committee (SAC/TC121) centralized. This section is drafted. Xi'an Institute Ltd. furnace, furnace Metallurgical Engineering Technology Center, the State Quality Supervision and Inspection Center Furnace, Shaanxi Province electric engineering and technology research center. The main drafters of this section. Fort Liu Fu, Ge Hua, Huangkui Gang, Zhu Lin. Industrial electric energy classification means Part 41. Push resistance heating unit

1 Scope

This section GB/T 30839 specifies the various types of push-type resistance heating unit (hereinafter referred to as "push Boiler Unit") energy range, can Consumption parameters, energy consumption and energy classification index measuring method. This section applies to a natural atmosphere furnace atmosphere and controlled atmosphere, various types of industrial temperature rating in the range of 150 ℃ ~ 1350 ℃ With push furnace unit. Push furnace unit according to the process can be divided into many types of uses, such as. heating unit, quenching unit, annealing line, sintering units, unit carburizing, nitriding Units, soldering machines and other groups. In addition to the energy unit energy consumption indicators classification and measurement unit also outside the main energy-consuming device push furnace Parameters were grading, as the main parameters of energy status of the unit.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2900.23-2008 Electrotechnical terminology industrial electric equipment GB/T 10066.1-2004 Test methods for electroheat installations - Part 1. General section GB/T 10066.4-2004 Test methods for electric equipment - Part 4. Indirect resistance furnaces GB/T 13324-2006 term heat treatment equipment

3 Terms and Definitions

GB/T 2900.23-2008, GB/T 13324-2006 define the following terms and definitions apply to this document. 3.1 Comparable unit power consumption comparablespecificconsumption Comparable consumption Depending on the product material, and using a furnace gas heating process is different for process coefficient according to relevant regulations, the material coefficients and coefficients of gas stove Select the quality of products after processing units converted to comparable standards of product quality (reduced mass), calculated from actual production and consumption of products The ratio of equivalent quality. Units of kilowatt-hours per ton (kW · h/t). 3.2 Air furnace loss ratio ratioofno-loadloss Air furnace percentage loss of rated power.

4 energy range

4.1 Push unit energy consumption of the furnace unit power consumption involved should include. a) Units powered main circuit input power consumption meter. Including supporting special furnace transformer (if this configuration), designed with the power supply cabinet, the main

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 30839.41-2014_English be delivered?

Answer: Upon your order, we will start to translate GB/T 30839.41-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 30839.41-2014_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 30839.41-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.