Condition monitoring and diagnostics of machines -- Thermography -- Part 1: General procedures
| Valid |
GB/T 30831.1-2014
|
PDF similar to GB/T 30831.1-2014
Basic data | Standard ID | GB/T 30831.1-2014 (GB/T30831.1-2014) | | Description (Translated English) | Condition monitoring and diagnostics of machines -- Thermography -- Part 1: General procedures | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | J04 | | Classification of International Standard | 17.160 | | Word Count Estimation | 27,252 | | Date of Issue | 6/24/2014 | | Date of Implementation | 3/1/2015 | | Regulation (derived from) | National Standards Bulletin No. 14 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 30831.1-2014: Condition monitoring and diagnostics of machines -- Thermography -- Part 1: General procedures ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Condition monitoring and diagnostics of machines - Thermography - Part 1. General procedures
ICS 17.160
J04
National Standards of People's Republic of China
Machine condition monitoring and diagnostic thermal imaging
Part 1. General
Part 1. Generalprocedures
(ISO 18434-1.2008, IDT)
Issued on. 2014-06-24
2015-03-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
Thermal imaging technology 3 4
5 4 relative thermal imaging
6 non-contact temperature measurement with infrared thermal imager 5
Baseline measurements 7 5
8 Security 5
Calibration 9 5
10 5 Data Acquisition
11 Customer Responsibilities 6
Scene 12 reflected temperature, emissivity and attenuating media measuring 6
13 Temperature severity assessment guidelines 6
14 profile assessment guidelines 7
15 8 Diagnosis and Prediction
8 16 test reports
17 Qualification 9
Field measurements in Appendix A (normative) reflected apparent temperature and emissivity of 10
Annex B (informative) safety rules and precautions 14
Annex C (informative) Case 15
References 22
Foreword
GB/T 30831 "machine condition monitoring and diagnostic thermal imaging" consists of the following components.
--- Part 1. General;
--- Part 2. Analyzing image and diagnostics.
This part of GB/T 30831 Part 1.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with ISO 18434-1.2008 "machine condition monitoring and diagnostic thermal imaging - Part 1. General"
(In English).
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB/T 20921-2007 machine condition monitoring and diagnostics Vocabulary (ISO 13372.2004, IDT);
--- GB/T 22393-2008 machine condition monitoring and diagnostics of general guidelines (ISO 17359.2003, IDT);
--- GB/T 22394-2008 machine condition monitoring and diagnostic data interpretation and diagnostics techniques General guidelines (ISO 13379.
2003, IDT);
--- GB/T 23713.1-2009 machine condition monitoring and predictive diagnostics - Part 1. General guidelines (ISO 13381-1.
2004, IDT).
This section makes the following editorial changes.
--- In the "References" added "GB/T 19870-2005 industrial detect infrared camera."
This part of the National mechanical vibration, shock and condition monitoring Standardization Technical Committee (SAC/TC53) and focal points.
This section is drafted. Guangzhou SATIR Co., Ltd., Hubei Electric Power Company State Grid Electric Power Research Institute, China Measurement Technology
Surgery Research Institute, Beijing Institute of Technology.
The main drafters of this section. Zhaofei Yu, Wu Tao FOR THERMAL Zhu Sha, Gregory, Zhang Taiguo, causing Zhang, Zhu Feibing.
Introduction
This section gives the machine condition monitoring and diagnostics in infrared thermography (IRT) Application Guide section. In the state of the machine
When monitoring infrared thermal imaging can be used to identify anomalies and recording machine status. Because the machine is running, poor lubrication, misalignment, parts
Wear or abnormal load will lead to abnormalities.
Infrared thermal imaging based on measurements of a target surface radiation heat distribution, and translate them into the radiation intensity difference plot (surface temperature map)
Or thermal spectra. Thus, before making an infrared thermal imaging measurement engineer, it requires an understanding of the heat, and the temperature of the different types of heat transfer basics.
All machines are running to generate heat, in the current process itself or may be a variety of process combinations to friction or energy loss forms, it
It is an inherent characteristic of a process in the medium. Thus, the temperature into machine performance monitoring, condition monitoring key parameters and fault diagnosis. Infrared
Thermal imaging technology is ideal for temperature monitoring, because the infrared thermal imaging provides complete thermal images of a machine or parts, having a non-physical connection
Touch (non-invasive), set up a simple and fast measurement results and so on.
Compared with contact thermometer, an important advantage of the radiation thermometer is fast response, energy measured object to the speed of light to transmit
sensor. The response speed of the radiation thermometer milliseconds or even microseconds. Another advantage of the radiation thermometer is its high sensitivity, because
They can detect very small temperature difference between the target and in the form of heat "map" of the show.
Although infrared thermal imaging has proved very useful, but there are still some limitations in measuring Most low emissivity surface, because radiation measurement
Signals are susceptible to generate unacceptable errors.
Machine condition monitoring and diagnostic thermal imaging
Part 1. General
1 Scope
This section GB/T 30831, introduced a machine condition monitoring and diagnostics of infrared thermal imaging applications. Here the "Machine" includes Machine
Auxiliary mechanical equipment, such as valves, fluid mechanical or electrical equipment, and associated heat exchangers. This section also describes the performance evaluation and the machine has
Off infrared applications.
This section includes.
--- With machine condition monitoring and diagnostics related to infrared thermal imaging terminology;
--- Infrared thermal imaging process types and their advantages;
--- Use thermal imaging to identify anomalies and to establish guidelines for severity assessment criteria;
--- Machine infrared thermal imaging measurement methods and requirements, including safety recommendations;
--- Data interpretation, evaluation criteria and reporting requirements of the information;
--- Confirmation and compensation reflected apparent temperature, emissivity and attenuating media.
This section also includes the use of quantitative infrared thermal imagers measure the surface temperature of a target, the recognition and compensation reflected apparent temperature, emissivity
Rate and attenuation medium inspection procedures.
Note. The analysis will also develop guidelines for specific applications.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO 13372 machine condition monitoring and diagnostics vocabulary (Conditionmonitoringanddiagnosticsofmachines-
Vocabulary)
ISO 13379 machine condition monitoring and diagnostic data interpretation and diagnostic techniques of general guidelines (Conditionmonitoringand
diagnosticsofmachines-Generalguidelinesondatainterpretationanddiagnosticstechniques)
ISO 13381-1 Machine condition monitoring and predictive diagnostics - Part 1. General guidelines (Conditionmonitoringanddiag-
nosticsofmachines-Prognostics-Part 1. Generalguidelines)
ISO 17359 machine condition monitoring and diagnostics of general guidelines (Condition monitoringanddiagnosticsof
machines-Generalguidlines)
ISO 18436-7 machine condition monitoring and diagnostics of personnel certification and assessment of personnel - Part 7. Thermal Imaging (Condition
monitoring and diagnostics of machines-Requirements for qualification and assessment of
personnel-Part 7. Thermography)
ASTME1897 Infrared Imaging Radiometer Standard Test Method for Measuring and Compensating attenuation medium transmission rate (Standardtest
methodsformeasuringandcompensatingfortransmittanceofanattenuatingmediumusinginfrared
imagingradiometers)
3 Terms and Definitions
ISO 13372 define the following terms and definitions apply to this document.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30831.1-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30831.1-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30831.1-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30831.1-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|