US$399.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30738-2014: Determination of radionuclide in marine sediment -- Gamma spectrometry Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30738-2014 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Determination of radionuclide in marine sediment -- Gamma spectrometry
| Valid |
GB/T 30738-2014
|
PDF similar to GB/T 30738-2014
Basic data | Standard ID | GB/T 30738-2014 (GB/T30738-2014) | | Description (Translated English) | Determination of radionuclide in marine sediment -- Gamma spectrometry | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | Z17 | | Classification of International Standard | 07.060; 13.060 | | Word Count Estimation | 17,178 | | Date of Issue | 6/9/2014 | | Date of Implementation | 10/1/2014 | | Quoted Standard | GB/T 12763.8-2007; GB/T 16145-1995; GB 17378.3-2007 | | Regulation (derived from) | National Standards Bulletin No. 11 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This Standard specifies the use of high-purity germanium [HPGe] �� spectrometer marine sediments natural or artificial �� conventional method of measuring radionuclide activity. This Standard applies to the determination of activity above the laboratory det |
GB/T 30738-2014: Determination of radionuclide in marine sediment -- Gamma spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of radionuclide in marine sediment. Gamma spectrometry
ICS 07.060; 13.060
Z17
National Standards of People's Republic of China
Determination of radionuclides in marine sediments
γ spectrometry
Issued on. 2014-06-09
2014-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Summary of Method 2
Preparation 5 standard calibration source 2
6 Equipment 2
7 Sampling and sample preparation 3
8 assay procedure 4
Quality assurance and control 9 8
8 10 test reports
The detection efficiency curve equation in Appendix A (normative) different geometrical height of the sample 10
Appendix B (Informative Appendix) γ Spectrometry detection limit of 11
Annex C (informative) Determination of radionuclides in marine sediments record sheet format 12
References 13
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard by the National Standardization Technical Commission for Oceanography (SAC/TC283) centralized.
This standard was drafted. South China Sea Environmental Monitoring Center, State Oceanic Administration, State Oceanic Administration, Third Institute of Oceanography.
The main drafters of this standard. Li Dongmei, doors Wu, Zhou Peng, Cai Syria, Chen Jiahui, Zhao Li, Wang Hua, Tianxiu Lei, Liang Qian Lin, Zheng far, the forest ends,
Huang Chuguang, Wujin Xiao Fang HTC, Wu Lingling, Zhang standard, home inspection Zhen.
Determination of radionuclides in marine sediments
γ spectrometry
Warning --- personnel should use this standard regular laboratory work experience. This standard does not point out all possible security asked
question. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.
1 Scope
This standard specifies the use of high-purity germanium [HPGe] γ spectrometer measured in marine sediment natural or artificial radionuclide γ activity routine
method.
This standard applies to the determination of the laboratory activity above the detection limit, and each nuclide γ characteristic lines can distinguish open marine sediments
sample.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 12763.8-2007 oceanographic survey - Part 8. Marine Geology Geophysical Survey
GB/T 16145-1995 biological sample γ spectrum analysis of radionuclides
GB 17378.3-2007 marine monitoring Part 3. Sample collection, storage and transportation
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Background background
In the γ spectrum, in addition to the sample count, other factors, such as cosmic rays, radioactive contamination, electromagnetic interference generated in the spectrum
count.
3.2
Background count rate backgroundcountrate
In the γ spectrum in addition to the radioactive sample, other factors count rate.
[GB 11743-1989, the definition 2.3]
3.3
Detection efficiency detectionefficiency
Under certain conditions detected, and the number of particles measured in the same time interval within the radiation source to the total number of species on the particle detector
Ratio.
[GB 11743-1989, the definition 2.5]
3.4
Detection limit lowlimitofdetection
At a given confidence level spectrometer can detect the lowest activity.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30738-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30738-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30738-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30738-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|