US$854.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30703-2014: Microbeam analysis -- Guidelines for orientation measurement using electron backscatter diffraction Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30703-2014 | English | 854 |
Add to Cart
|
3 days [Need to translate]
|
Microbeam analysis -- Guidelines for orientation measurement using electron backscatter diffraction
| Valid |
GB/T 30703-2014
|
PDF similar to GB/T 30703-2014
Basic data | Standard ID | GB/T 30703-2014 (GB/T30703-2014) | | Description (Translated English) | Microbeam analysis -- Guidelines for orientation measurement using electron backscatter diffraction | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | G04 | | Classification of International Standard | 71.040.50 | | Word Count Estimation | 43,491 | | Date of Issue | 6/9/2014 | | Date of Implementation | 12/1/2014 | | Quoted Standard | ISO/IEC 17025; ISO/IEC GUIDE 98-3 | | Adopted Standard | ISO 24173-2009, IDT | | Regulation (derived from) | National Standards Bulletin No. 11 of 2014 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the use of electron backscatter diffraction (EBSD) technology for crystal orientation measurement guidelines, the measurement data with high reliability and repeatability, this standard establishes sample preparation, instrument co |
GB/T 30703-2014: Microbeam analysis -- Guidelines for orientation measurement using electron backscatter diffraction ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Microbeam analysis. Guidelines for orientation measurement using electron backscatter diffraction
ICS 71.040.50
G04
National Standards of People's Republic of China
Microbeam analysis of electron backscatter diffraction orientation
Analysis Guidelines
(ISO 24173.2009, IDT)
Issued on. 2014-06-09
2014-12-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 EBSD device 6
5 7 operating condition
6 EBSP index calibration required correction 11
7 analysis process 14
8 Measurement uncertainty 14
9 analysis results release 15
Appendix A (Informative Appendix) EBSD works 16
Appendix B (Normative Appendix) EBSD sample preparation 17
Annex C (informative) crystallography, EBSP calibration and other useful information associated with EBSD 22
References 37
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard translation method using equivalent international standards. ISO 24173.2009 "micro-beam analysis of electron backscatter diffraction determination of orientation
Guidelines".
Correspondence between the consistency of the standards of international documents and normative references of the following documents.
--- GB/T 27025-2008 testing and calibration laboratories General requirements (ISO /IEC 17025.2005, IDT).
The standard micro-beam analysis by the National Standardization Technical Committee (SAC/TC38) and focal points.
This standard was drafted. Shanghai Power Equipment Research Institute, Baosteel Group Central Research Institute, Chinese Academy of Sciences Shanghai Silicate Institute
The study.
The main drafters. Zhang Zuogui, super song, Chen Jiaguang, Zeng Yi.
Introduction
Electron backscatter diffraction (EBSD) with a scanning electron microscope (SEM), or SEM-FIB (focused ion beam) or electron probe was
Micro Analyzer (EPMA) and surface scanning measuring the crystal samples obtained crystallographic information technology [1,2].
Electron backscattering pattern (EBSP) is inclined to the surface of the crystal sample high fixed incident electron beam irradiation, and interact with the surface atoms
And the occurrence of back-scattering results. In order to improve the efficiency of back-scattering, usually the sample surface normal direction of the electron swept about 70 ° angle. EBSP pass
In EBSD formed of a scintillation counter (e.g., single crystal YAG or screen) and a charge coupled device (CCD camera) imaging is often composed of
The detector can also be imaged on photographic film.
Through analysis of the EBSP, crystal orientation can be measured, it may be some minor phase structure within the region analyzed. Since EBSD is
Incident electron with the sample surface atoms tens of nanometers diffraction effects within the depth of interaction occurs, and therefore the application of this technique requires special
Do not pay attention to the preparation of the sample [3].
EBSD spatial resolution is strongly dependent on the operating parameters of the instrument and the nature of the material to be measured, in general, a tungsten filament SEM
Receive approximately 0.25μm spatial resolution, and the resolution limit of the electron field emission gun scanning electron microscope (FEGSEM) up to 10nm ~
50nm. Typically, crystal orientation measurement accuracy is approximately 0.5 °.
By EBSD sample surface analysis of a region, you can get in the region reflect spatial variations in the orientation phase composition, EBSP quality
And other related surface profile measurements. These data can be used for quantitative analysis of the microstructure, e.g., measuring the average grain size (or size
Distribution), crystallographic texture (orientation distribution) or contain the number of the special nature of grain boundaries (such as twin grain boundaries). EBSD technique combined with precision even
Continued cutting techniques, such as focused ion beam (FIB) technology, you can get a three-dimensional microstructure characteristics of the material [4].
In order to better grasp the EBSD technique and accurate data processing, EBSD users should be familiar with the principles and characterization of crystal orientation
Various methods (both aspects are related literature [5,6] has been described in).
Microbeam analysis of electron backscatter diffraction orientation
Analysis Guidelines
1 Scope
This standard gives the electron backscatter diffraction (EBSD) technology for crystal orientation measurement guidelines, the measurement data with higher
Reliability and reproducibility of this standard to establish a sample preparation, instrument configuration, calibration and general principles of data collection.
This standard applies to bulk crystal grain orientation for EBSD analysis of the sample.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ISO /IEC 17025 General requirements for testing and calibration laboratories (Generalrequirementsforthecompetenceof
testingandcalibrationlaboratories)
ISO /IEC Guide98-3 Measurement Uncertainty Part 3. Guide to the Expression of Uncertainty in Measurement (GUM.1995) (Uncertainty
ofmeasurement-Part 3. Guidetotheexpressionofuncertaintyinmeasurement (GUM.1995)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Crystal crystal
In space by the rules, you can repeat the arrangement of atoms composed. Common space groups, crystal lattice constant (including the length between the edge and the edge
Angle) and the position of atoms in the unit cell described [7,8].
Note 1. For example, the aluminum crystal can be a side length 0.40494nm face-centered cubic (single cell) to represent.
Note 2. respectively along the [100], [111] and [110] crystal direction of observation of aluminum (4 × 4 × 4 unit cell) model of the atomic arrangement shown in Figure 1, while Figure 1 shows the
Its corresponding orientation of each crystal spherical Kikuchi pattern, the fourth, third and second symmetrical apparent, looks like mirror.
Note 3. For those unfamiliar with crystallography beginners, we recommend that reference to some standard textbooks [7-9].
Note 4. Introduction to the knowledge about crystallography and having a cubic crystal symmetry material EBSP index calibration guide in Appendix C.
3.2
Planes crystalplane
Usually (the hkl) plane represented by a representative of the unit cell of the crystal planes a, b, c axis intercept is 1/h, 1/k, 1/l, where, h,
k, l is an integer.
Note 1. h, k, l are usually called crystal plane Miller indices.
Note 2. For more, see Appendix C.
3.3
Crystal orientation crystaldirection
Usually the direction [uvw] expressed, on behalf of a vector in the direction of a, b, c crystal axes vectors of multiples.
NOTE. For more, see Appendix C.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30703-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 30703-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30703-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30703-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|