HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189759 (19 Oct 2025)

GB/T 30104.205-2013 English PDF

US$514.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 30104.205-2013: Digital addressable lighting interface -- Part 205: Particular requirements for control gear -- Supply voltage controller for incandescent lamps (device type 4)
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 30104.205-2013English514 Add to Cart 3 days [Need to translate] Digital addressable lighting interface -- Part 205: Particular requirements for control gear -- Supply voltage controller for incandescent lamps (device type 4) Valid GB/T 30104.205-2013

PDF similar to GB/T 30104.205-2013


Standard similar to GB/T 30104.205-2013

GB/T 24825   GB/T 9473   GB/T 32483.2   GB/T 30104.201   GB/T 30104.203   GB/T 30104.204   

Basic data

Standard ID GB/T 30104.205-2013 (GB/T30104.205-2013)
Description (Translated English) Digital addressable lighting interface -- Part 205: Particular requirements for control gear -- Supply voltage controller for incandescent lamps (device type 4)
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K74
Classification of International Standard 29.140.50; 29.140.99
Word Count Estimation 26,219
Quoted Standard GB/T 30104.101-2013; GB/T 30104.102-2013
Adopted Standard IEC 62386-205-2009, IDT
Regulation (derived from) National Standards Bulletin No. 25 of 2013
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the incandescent associated with the electronic control device digital signal control protocol and test procedures.

GB/T 30104.205-2013: Digital addressable lighting interface -- Part 205: Particular requirements for control gear -- Supply voltage controller for incandescent lamps (device type 4)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Digital addressable lighting interface Part 205. Particular requirements for control gear Supply voltage controller for incandescent lamps (device type 4) ICS 29.140.50; 29.140.99 K74 National Standards of People's Republic of China Digital Addressable Lighting Interface Part 205. Particular requirements for control device Incandescent supply voltage controller (device type 4) Part 205. Particularrequirementsforcontrolgear- Supplyvoltagecontrolerforincandescentlamps (devicetype4) (IEC 62386-205.2009, IDT) Issued on. 2013-12-17 2014-11-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 2 General requirements 5 Electrical Specifications 2 6 Interface Power 2 7 Structure 2 Transport Protocol 8 Timing 2 9 Run Method 2 10 variable declarations 3 11 directive defines 4 12 test program 10 References 21 Figure 1 Application extended configuration instruction sequence Example 5 Figure 2, "Query dimmer status" and "query feature" Test Process 11 Figure 3 "Query failed state" testing process 12 Figure 4 "command from 242 to 248" Test Process 14 Figure 5 "choose dimming curve", "Query dimming curve" and "Query dimmer status" Test Process 15 6 "base system power" Test Process 16 7 "reference system power" 15 minutes of test time-out process 17 Figure 8 "Query reference measurement failed" the test process 18 Figure 9 "Query Expansion version" Test Process 19 10 "reserved for applications extended instruction" Test Process 20 Table 1 variable declaration 3 Table 2 dimming Bit 7 Table 3 Application of Extended Instruction Set Summary 9 Table 4 Instruction 241 "Query failed state" test conditions 13 Table 5 query command from 242 to 248 Table 14 Test

Foreword

GB/T 30104 "Digital Addressable Lighting Interface" is divided into 13 parts. --- Part 101. General requirements for systems; --- Part 102. General requirements for the control device; --- Part 103. General requirements for control equipment; --- Part 201. control means special requirements for fluorescent lamps (device type 0); --- Part 202. Particular requirements for control self-contained emergency lighting (device type 1); --- Part 203. Particular requirements for control of discharge lamps (excluding fluorescent lamps) (device type 2); --- Part 204. control means special requirements for low-voltage halogen lamps (device type 3); --- Part 205. Particular requirements for control devices incandescent supply voltage controller (device type 4); --- Part 206. Particular requirements for digital signal control device into a DC voltage (device type 5); --- Part 207. control means special requirements of LED modules (device type 6); --- Part 208. control means special requirements for the switching function (device type 7); --- Part 209. control means special requirements for color control (device type 8); --- Part 210. control program means a special device requirements (device type 9). This section GB/T Part of 20,530,104. This section drafted in accordance with the rules of GB/T 1.1-2009 and GB/T 20000.2-2009 given. This section uses the translation method identical with IEC 62386-205.2009 "Digital addressable lighting interface - Part 205. control means Particular requirements incandescent supply voltage controller (device type 4). " This part is proposed by the China National Light Industry Council. This part of the National Electric lighting Standardization Technical Committee (SAC/TC224) centralized. Drafting this Part. Guangdong Product Quality Supervision and Inspection Institute, Zhongshan Productivity Promotion Center, Deqing County Metro illuminator Material Co., Ltd., Foshan City, China Electrical Lighting Co., Ltd., Beijing Institute of electric light. The main drafters of this section. LI Zi-li, Yang Guozheng, Tsing Yi, Yang Chi District, Jiang Shan, Duan Yan Fang, Zhao Xiurong.

Introduction

This section will be published simultaneously with the GB/T 30104.101 and GB/T 30104.102. The GB/T 30104 is divided into several parts published separately For future amendments and revisions. If necessary, add additional requirements. When referring to GB/T 30104.101 or GB/T within 30104.102 any provisions of this section and the composition of GB/T 30104.2 ×× Department Other parts of the column clearly defines the order in terms of scope and testing. If necessary, this section includes additional requirements. group To GB/T 30104.200 series all parts are independent, and therefore does not contain references to each other. Requires that any provisions of GB/T 30104.101 or GB/T 30104.102 in this section to "in accordance with GB/T 30104.101 first 'N' chapter of the requirements, "a reference to the form of the sentence, the sentence could be interpreted as all requirements related to the provision of Section 101 or Section 102 are But it does not apply to Part 205 except the control device contains a particular type of lamp. Unless otherwise stated, figures in this section are used in the decimal. Hexadecimal numbers using 0xVV format, several of which VV value. Binary digits or using XXXXXXXXb XXXXXXXX format, wherein X is 0 or 1; "x" means "not in binary For consideration. " Digital Addressable Lighting Interface Part 205. Particular requirements for control device Incandescent supply voltage controller (device type 4)

1 Scope

GB/T 30104 provisions of this part of the incandescent related electronic control unit digital signal control protocol and test procedures.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 30104.101-2013 digital addressable lighting interface - Part 101. General requirements for systems (IEC 62386-101. 2009, IDT) GB/T 30104.102-2013 digital addressable lighting interface - Part 102. General requirements for control devices (IEC 62386- 102.2009, IDT)

3 Terms and Definitions

GB/T 30104.101-2013 Chapters 3 GB/T 30104.102-2013 defined in Chapter 3 and the following terms and definitions apply In this document. 3.1 Reference measurement referencemeasurement Measuring the actual lamp load. NOTE. The control unit determines the actual lamp load, and not required by this section with its internal procedures and measurements. 3.2 Reduced load detection detectionofloaddecrease Significantly lower than the actual lamp load recognition during the "reference measuring" success measured load. Note. For the load increases or decreases belongs obvious criteria, can only be determined by the manufacturer, these guidelines should be described in the specification. 3.3 Increased load detection detectionofloadincrease Significantly higher than the actual lamp load recognition during the "reference measuring" success measured load. Note. For the load increases or decreases belongs obvious criteria, can only be determined by the manufacturer, these guidelines should be described in the specification. 3.4 Thermal overload thermaloverload The control device exceeds the maximum allowable temperature situation. 3.5 Thermal shutdown thermalshut-down Control means off the light, because the automatic reduction in the amount of output can not prevent continuous thermal overload.