US$4519.00 · In stock Delivery: <= 14 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 30104.103-2017: Digital addressable lighting interface -- Part 103: General requirements -- Control devices Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 30104.103-2017 | English | 4519 |
Add to Cart
|
14 days [Need to translate]
|
Digital addressable lighting interface -- Part 103: General requirements -- Control devices
| Valid |
GB/T 30104.103-2017
|
PDF similar to GB/T 30104.103-2017
Basic data | Standard ID | GB/T 30104.103-2017 (GB/T30104.103-2017) | | Description (Translated English) | Digital addressable lighting interface -- Part 103: General requirements -- Control devices | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K74 | | Classification of International Standard | 29.140; 29.140.50 | | Word Count Estimation | 226,284 | | Date of Issue | 2017-11-01 | | Date of Implementation | 2018-11-01 | | Regulation (derived from) | National Standard Announcement 2017 No. 29 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China |
GB/T 30104.103-2017: Digital addressable lighting interface -- Part 103: General requirements -- Control devices ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Digital addressable lighting interface-Part 103. General requirements-Control devices
ICS 29.140; 29.140.50
K74
National Standards of People's Republic of China
Digital Addressable Lighting Interface Part 103.
General requirements for control equipment
Digitaladdressablelightinginterface-Part 103.
(IEC 62386-103.2014, IDT)
Posted.2017-11-01
2018-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
China National Standardization Administration released
Directory
Foreword V.
Introduction Ⅵ
1 Scope 1
2 Normative references 1
3 Terms and definitions 1
4 Overview 3
5 Electrical Specifications 4
6 interface power supply 4
7 Transmission Protocol Structure 4
8 timing 6
9 method of operation 7
10 Variables of the statement 24
Definition of order 26
12 Test Procedure 43
References 219
Figure 1 IEC 62386 Graphical Overview IV
Figure 2 rated current test 66
Table 1 24-bit command frame encoding 4
Table 2 Example byte in command frame 5
Table 3 24-bit event message frame coding 6
Table 4 instance type 8
Table 5 Feature Type 8
Table 6 Example Group Variables 9
Table 7 Device Address Information in Power Failure Event 10
Table 8 Event Addressing Plan 10
Table 9 Signal Levels (Approx. 50%) with Accuracy and Input Value 11
Table 10 reads a 4-byte instance of the input value Query Sequence 12
Table 11 Memory Map of Main Memory 14
Table 12 Memory Bank 0 Memory Map 17
Table 13 Memory Bank 1 Memory Map 19
Table 14 Control Equipment Capabilities 23
Table 15 Control Equipment Status 23
Table 16 Example Status 23
Table 17 Device Variable Declaration 24
Table 18 Declaration of Instance Variables
Table 19 Example Event Messages 26
Table 20 Device Event Messages 26
Table 21 Standard Commands
Table 22 Special Commands (Implemented by Both Application Controller and Input Device) 30
Table 23 Device addressing "INITIALISE (device)" 40
Table 24 Accidental output 46
Table 25 Checking 103 Factory Default Test Parameters 55
Table 26 Test Program Parameters Used to check 103 factory default 59 for each logical unit
Table 27 Bit Timing Test Sequence Parameters 62
Table 28 Maximum and minimum system voltage test parameters 64
Table 29 Voltage Transmission Test Procedure Parameters
Table 30 Send Rising and Falling Edge Tests Parameter 69
Table 31 Test Sequence Parameters for Sending Bit Timing 73
Table 32 receives the parameters of frame timing test sequence 74
Table 33 Receiver Startup Test Sequence Parameter 76
Table 34 Test Sequence Parameters for Receiving Bit Timing 78
Table 35 Extended Receive Bit Timing Test Parameter 83
Table 36 Parameters for Recovery of Test Sequence Receiver Frames Invalid and Frame Size Invalid 83
Table 37 Receive Frame Timing Test Parameter 85
Table 38 Collision Avoidance Signal Transmission Test Parameter 88 based on priority
Table 39 Sends the Collision Detection Parameter 91 of the Free Phase
Table 40 Test Parameter for Transmission Collision Detection Extended Active 94
Table 41 resets the instance group test parameter 98
Table 42 Sends two test parameters 105 for timeout
Table 43 Sends two timeout (example) test parameters 108
Table 44 (Equipment) Test Sequence Parameters 111
Table 45 Test Sequence Parameters 114
Table 46 Sets Short Address Test Parameter 122
Table 47 Parameters for Reset/Power-Up Value (Device) Test 124
Table 48 Reset/Power-Up Value (Example) Parameters for Test 126
Table 49 DTR0/DTR1/DTR2 Test Parameters 127
Table 50 DTR1.DTR0 and DTR2.DTR1 Test Parameters 128
Table 51 reads storage location test parameter 138 on memory 0
Table 52 reads test parameters 141 for storage location on memory 1
Table 53 Memory Write Test Parameters 147
Table 54 Enables Write Memory. Write Enable Status Test Parameter 150
Table 55 Write Store Enable. Timeout/Intermediate Command Test Parameter 153
Table 56 Memory Reset. Timeout/Intermediate Command Test Parameter 155
Table 57 resets memory test parameters 157
Table 58 Initialization - Device Addressing Test Parameters 160
Table 59 compares the parameters of the test 162
Table 60 Undo operation test parameters 164
Table 61 Short Address Programming Test Parameters 167
Table 62 Query Short Address 169
Table 63 Querying the Short Address Test Parameter 171
Table 64 Device Identification Test Parameters 173
Table 65 Addressing 2 Test Parameters 180
Table 66 Reserved Commands. Standard Device Command Test Parameter 203
Table 67 Reserved Instance Commands (Instance Type 0) Test Parameter 204
Table 68 Reserved Special Instruction Test Sequence Parameter 205
Foreword
GB/T 30104 "digital addressable lighting interface" is divided into 13 parts.
--- Part 101. General requirements system;
--- Part 102. General requirements of control devices;
--- Part 103. General requirements for control equipment;
--- Part.201. Particular requirements for control devices Fluorescent light (device type 0);
--- Part 202. Particular requirements for control devices Self-contained emergency lighting (equipment type 1);
--- Part 203. Particular requirements for control devices Discharge lamps (excluding fluorescent lamps) (type of equipment 2);
--- Part 204. Particular requirements for control gear Low - voltage tungsten halogen lamp (type of equipment 3);
--- Part 205. Particular requirements for control gear Incandescent lamp supply voltage controller (device type 4);
--- Part 206. Particular requirements for control equipment Digital signal to DC voltage (device type 5);
--- Part 207. Particular requirements for control devices LED module (device type 6);
--- Part 208. Particular requirements for control devices Switching function (device type 7);
--- Part 209. Particular requirements for control devices Color control (device type 8);
--- Part 210. Particular requirements for control devices Program device (device type 9).
This section GB/T 30104 Part 103.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method is equivalent to using IEC 62386-103.2014 "Digital Addressable Lighting Interface Part 103. General requirements
controlling device".
The documents of our country that are consistent with the corresponding international documents quoted in this part are as follows.
--- GB/T 30104.101-2013 Digital Addressable Lighting Interface Part 101. General Requirements System (IEC 62386-
101.2009, IDT)
--- GB/T 30104.102-2013 digital addressable lighting interface - Part 102. General requirements control device
(IEC 62386-102.2009, IDT)
This part is proposed by China National Light Industry Council.
This part of the National Lighting Standardization Technical Committee electric light source and its accessories Technical Committee (SAC/TC224/SC1)
Focused.
This part of the drafting unit. Jiangsu Asia Lighting Group Co., Ltd., Foshan Electrical and Lighting Co., Ltd., Chaoyang District, Beijing efficient Zhao Photo
Ming Technology Center, the National Semiconductor Light Source Product Quality Supervision and Inspection Center (Guangdong), Foshan City, All Electric Lighting Co., Ltd., Zhejiang Xiao You
Fish Intelligent Technology Co., Ltd., Hangzhou Maple Yongming Photoelectric Co., Ltd., Philips Lighting (China) Investment Co., Ltd., Tridonic Lighting
Sub (Shanghai) Co., Ltd.
The main drafters of this section. Yin Jinxing, Shen Qingyue, Wei Bin, Liu Qian, Li Benliang, Ke Baiquan, Wei Wei, Huang Jianming, Huang Feng, Wu Xuan Kai.
Introduction
IEC 62386 as a series of standards contains several parts. Part 1xx includes basic requirements. Part 101 is a system composed of one
General requirements; Part 102 extends to the general requirements for control devices; Part 103 extends to the general requirements for control equipment.
Part 2xx is the "General requirements for control devices" to extend the special requirements of the lamp (mainly for backward compatibility with IEC 62386 version 1
Sexual) and extend the special functional requirements of the control device.
Part 3xx, "General Requirements for Control Equipment," extends the special requirements for input devices, describes the type of instances and combines multiple
Some common types of cases.
This release of the first edition of IEC 62386-103 and IEC 62386-101.2014, IEC 62386-102.2014, and constitute IEC
62386-2xx control equipment, parts of the series, and constitute the IEC 62386-3xx control device special requirements of the various parts of the series formed as a
A series of the whole. The separate publication of each section is for the convenience of future amendments and modifications. When the whole series has other needs and get recognized
Available later, can be added.
The standard setting can be marked as below.
Figure 1 IEC 62386 graphical overview
When this part of IEC 62386 refers to any of the other two parts of the IEC 62386-1xx series, the provisions of this clause
The degree of application and the order of testing to be carried out. Other parts also include additional requirements, if necessary.
All numbers used in this standard are in decimal notation unless otherwise stated.
Hexadecimal numbers have a format of 0xVV, where VV is a numeric value. Binary numbers are in XXXXXXXXb format or XXXX
XXXX format, where X is 0 or 1, and "x" in binary numbers means "arbitrary value".
The following typographic expressions are used.
The variable .variableName or variableName [3.0] gives only 3-0 bits of variableName
Value range. [Lowest, highest]
Command. "Command name"
Digital Addressable Lighting Interface Part 103.
General requirements for control equipment
1 Scope
GB/T 30104 applies to this part of the digital signal from the electronic lighting control bus system control equipment. The control device
Meet the requirements of IEC 61347, DC power supply.
NOTE The tests described in this section are type tests and do not include the testing requirements for individual products in the manufacturing process.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
IEC 62386-101.2014 Digital Addressable Lighting Interface Part 101. General Requirements System (Digitaladdressable
lightinginterface-Part 102.Generalrequirements-System)
IEC 62386-102.2014 digital addressable lighting interface - Part 102. General requirements Control device (Digital
addressablelightinginterface-Part 102.Generalrequirements-Controlgear)
3 Terms and definitions
IEC 62386-101.2014 defined in Chapter 3 and the following terms and definitions apply to this document.
3.1
Broadcast
The addressing type that addresses all control device addresses in the system at the same time.
3.2
No address broadcast broadcastunaddressed
The addressing type for all control device addresses without short addresses in the system can be addressed at the same time.
3.3
Device command devicecommand
A command addressing the control device and having a value of 0xFE in the instance byte of the command frame.
3.4
Device group devicegroup
Address type for addressing a control device group in the system at the same time.
3.5
DTR data transfer register DTRdatatransferregister
Multi-purpose register used to exchange data.
3.6
Event
Instance reports, which are characterized by an event number, a change in input value, or a sequence of change in input value.
Note. The event number is determined by the instance type of the report being sent.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 30104.103-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 30104.103-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 10 ~ 14 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 30104.103-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 30104.103-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|