US$369.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29818-2013: Mass flow meter based on HART protocol general specification Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 29818-2013 | English | 369 |
Add to Cart
|
3 days [Need to translate]
|
Mass flow meter based on HART protocol general specification
| Valid |
GB/T 29818-2013
|
PDF similar to GB/T 29818-2013
Basic data Standard ID | GB/T 29818-2013 (GB/T29818-2013) | Description (Translated English) | Mass flow meter based on HART protocol general specification | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | N12 | Classification of International Standard | 17.120; 25.040 | Word Count Estimation | 16,146 | Quoted Standard | GB/T 2900.56-2008; GB 3836.1; GB 3836.2; GB 3836.3; GB 3836.4; GB 3836.9; GB 3836.19; GB/T 17212-1998; GB/T 17626.2; GB/T 17626.3; GB/T 17626.4; GB/T 17626.5; GB/T 17626.6; GB/T 17626.8; GB/T 18268.1-2010; GB/T 20728-2006; IEC 61158-5-20-2010; IEC 61158-6 | Regulation (derived from) | National Standards Bulletin No. 22 of 2013 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies: Based on HART Protocol Coriolis mass flowmeter about the HART Communication terms and definitions, classification, requirements and test methods. This standard applies: Based on HART Protocol Coriolis mass flowmeter. |
GB/T 29818-2013: Mass flow meter based on HART protocol general specification---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Mass flow meter based on HART protocol general specification
ICS 17.120; 25.040
N12
National Standards of People's Republic of China
Based on mass flowmeter HART protocol
General technical conditions
Issued on. 2013-11-12
2014-03-15 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 Category 2
5 Requirement 2
5.1 Operating Conditions 2
5.2 HART communication protocol 3
5.3 Electromagnetic Compatibility 9
5.4 10 explosion-proof performance
6 Test methods 10
6.1 test environment condition 10
6.2 HART communications protocol test 10
6.3 Compatibility Test Method capacitor 11
6.4 performance test explosion 11
Reference 12
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard was drafted. Xi'an Dongfeng Electrical Co., Ltd., Southwest University, Shenzhen Wan News Controls Co., Kaifeng Instrument Co.
Division Anton Xiamen Electronics Co., Ltd., Fujian on the Run Precision Instrument Co., Ltd., Chongqing Snyder Industrial Co., Ltd., Taiyuan Taihang traffic engineering
Cheng Co., Ltd., Beijing Rip three yuan Instrument Co., Ltd., Zhejiang Di yuan Instrument Co., Ltd., Siemens (China) Co., Ltd., Shanghai Automation
Instrumentation Co., Ltd., of Instrumentation Technology and Economy Institute, Chongqing Ivey Instrument Co., Ltd., Chongqing Sichuan Instrument Automation
Limited flow meter Branch, Shanghai Institute of Industrial Automation Instrumentation.
The main drafters. Zhang Peng, benefit all the people, Zhao Yixin, Xie Xiaohui, ROADS Du Cap would, Hong Xiaoping, Zhou Chong, Ge Jian, Guo,
Rendong Shun, Li, and Sun Xiangdong, Shi Hailin, Doulian Wang, Ni Min, Zhang Guiling, Zhang Chuan Chao, Zhang Jie, Wang Gang, Li Minghua, Huangqiao Li, Pan Dongbo.
Based on mass flowmeter HART protocol
General technical conditions
1 Scope
This standard specifies the terms and definitions based on the HART communication protocol HART Coriolis mass flow meter, classification, to
Sum test methods.
This standard applies to Coriolis mass flowmeter based on HART protocol.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2900.56-2008 Electrotechnical terminology control technology
GB 3836.1 explosive atmospheres - Part 1. General requirements for equipment
GB 3836.2 explosive atmospheres - Part 2. the flameproof "d" protection equipment
GB 3836.3 explosive atmospheres - Part 3. the increased safety "e" protection equipment
GB 3836.4 explosive atmospheres - Part 4. the intrinsically safe "i" protection equipment
GB 3836.9 Electrical apparatus for explosive gas atmospheres - Part 9. the Encapsulation "m" protection equipment
GB 3836.19 Explosive atmospheres - Part 19. Fieldbus intrinsically safe concept (FISCO)
GB/T 17212-1998 industrial process measurement and control - Terms and definitions
GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test
GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5 electromagnetic compatibility test and measurement technology surge (impact) immunity test
GB/T 17626.6 Electromagnetic compatibility Testing and measurement techniques Immunity to conducted disturbances induced field
GB/T 17626.8 Electromagnetic compatibility Testing and measurement techniques - Power frequency magnetic field immunity test
Electrical equipment EMC requirements - Part GB/T 18268.1-2010 measurement, control and laboratory use 1. General requirements
GB/T 20728-2006 Measurement of fluid flow in closed conduits of the Coriolis flowmeter selection, installation and user's guide
IEC 61158-5-20.2010 Industrial communication networks - Fieldbus specifications - Part 5-20. Application layer service definition - Type 20
Basis (Industrialcommunication networks-Fieldbusspecifications-Part 5-20. Applicationlayer
servicedefinition-Type20elements)
IEC 61158-6-20.2010 Industrial communication networks - Fieldbus specifications - Part 6-20. Application layer service definition - Type 20
Basis (Industrialcommunicationnetworks-Fieldbusspecifications-Part 6-20. Applicationlayerproto-
colspecification-Type20elements)
IEC 61784-1.2010 Industrial communication networks profiles - Part 1. Fieldbus profile (Industrialcommunication
networks-Profiles-Part 1. Fieldbusprofiles)
3 Terms and Definitions
GB/T 2900.56-2008, GB/T 17212-1998 and GB/T 20728-2006 and the following definition of terms and definitions appropriate
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29818-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 29818-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 29818-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29818-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|