US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29815-2013: The electromagnetic flowmeter based on HART protocol general technical specification Status: Valid
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 29815-2013 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
The electromagnetic flowmeter based on HART protocol general technical specification
| Valid |
GB/T 29815-2013
|
PDF similar to GB/T 29815-2013
Basic data Standard ID | GB/T 29815-2013 (GB/T29815-2013) | Description (Translated English) | The electromagnetic flowmeter based on HART protocol general technical specification | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | N12 | Classification of International Standard | 17.120.10 | Word Count Estimation | 10,136 | Quoted Standard | GB 3836.1-2010; GB 3836.2-2010; GB 3836.4-2010; GB 3836.9-2010; GB/T 17626.2-2006; GB/T 17626.4-2008; GB/T 17626.5-2008; GB/T 17626.8-2008; GB/T 17626.11-2008; GB/T 29910.1; JB/T 9248 | Regulation (derived from) | National Standards Bulletin No. 22 of 2013 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies: Electromagnetic Flowmeter HART protocol terms and definitions, requirements and test methods. This standard applies to: Application HART protocol electromagnetic flowmeter. |
GB/T 29815-2013: The electromagnetic flowmeter based on HART protocol general technical specification ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
The electromagnetic flowmeter based on HART protocol general technical specification
ICS 17.120.10
N12
National Standards of People's Republic of China
Electromagnetic Flowmeter HART protocol
General technical conditions
Issued on. 2013-11-12
2014-03-15 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 requires 2
4.1 Normal operating conditions 2
4.2 HART protocol 2
4.3 HART Test 3
4.4 Electromagnetic compatibility 4
4.5 5 explosion-proof performance
4.6 Other Requirements 5
Test Method 5 5
5.1 Test conditions 5
5.2 Communication Function 5
5.3 Electromagnetic compatibility 6
Proof performance 6 5.4
5.5 Other requirements 6
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Machinery Industry Federation.
This standard by the national industrial process measurement and control Standardization Technical Committee (SAC/TC124) centralized.
This standard was drafted. Chongqing Sichuan Instrument Automation Co., Southwest University, Siemens (China) Co., Ltd., Beijing Far East Instrument
Ltd., Fujian, Macao and Thailand Automation Equipment Co., Ltd., Tianjin billion ring Automation Instrumentation Technology Co., Ltd., Kaifeng Instrument Co., Ltd., North
Beijing Rip three yuan Instrument Co., Ltd., Yuyao Yinhuan Traffic Instrument Co., Ltd., Fujian Shunchang Rainbow Run Precision Instrument Co., Ltd., Zhejiang Di yuan
Instrument Co., Ltd., Hangzhou Pangu Automation System Co., Ltd. Anton Xiamen Electronics Co., Ltd. Shenzhen Wan News Controls, Ann
Logo Blue Run Automation Instrumentation Co., Fujian on the Run Precision Instrument Co., Ltd., Fuzhou Baxter Automation Equipment Co., Ltd., Central days
Instrument Co., Ltd., Shanghai ABB Engineering Co., Ltd., of Instrumentation Technology and Economy Institute, Shanghai Automation Instrumentation Unit
Parts Limited, Shanghai Weier Tai Industrial Automation Co., Ltd., Shanghai Industrial Automation Instrument Research Institute, Chongqing Instrument Co. Ivey
the company.
The main drafters of this standard. Shi Lei, Huang Yi Pu, Wang Guanghui, Zhang Yu, Lu Jing, Zhong Xiurong, Shi Hailin, Doulian Wang, Wang Yue, Chen, Liu Zhonghai,
DU chapter will, in Li, Zhu Jiashun, Chen Zhiyang, Sun Xiangdong, Guo hero, Hong Xiaoping, Yuan Minxun, Xie Xiaohui, Chen Wanlin, Zou Chong, Ge Jian, Qi Jianfeng,
Chenhui Qing, Shen Wei is willing, Mei Ke, Ni Min, gold up, Chen Jie, Li Minghua, Zhang Chuan Chao, Wang Ah so.
Electromagnetic Flowmeter HART protocol
General technical conditions
1 Scope
This standard specifies the terms and definitions Electromagnetic Flowmeter HART protocol requirements and test methods.
This standard applies to the application of electromagnetic flowmeter HART protocol.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 3836.1-2010 explosive atmospheres - Part 1. General requirements for equipment
GB 3836.2-2010 explosive atmospheres - Part 2. the flameproof enclosure "d" protection equipment
GB 3836.4-2010 Explosive atmospheres - Part 4. the intrinsically safe "i" protection equipment
GB 3836.9-2006 Electrical equipment for explosive gas atmospheres - Part 9. Encapsulation "m"
GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test
GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test
GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test
GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test
GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity
test
GB/T 29910.1 Industrial communication networks - Fieldbus specifications - Type 20. HART specification
JB/T 9248 electromagnetic flowmeter
3 Terms and Definitions
GB/T 29910.1 defined and the following terms and definitions apply to this document.
3.1
HART protocol HighwayAddressableRemoteTransducerprotocol
One kind of compatible with traditional 4mA ~ 20mA analog signal system on-site digital communication protocols, referred to as the HART protocol. Protocol Specification Set
Including the physical layer, data link layer and application layer protocol; this agreement is US Rosement company launched in 1985 for intelligent scene
Communication protocol between instruments and control room equipment.
3.2
Electromagnetic Flowmeter electromagneticflowmeterapplyingHARTprotocol HART protocol
Electromagnetic Flowmeter with HART protocol functions.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29815-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 29815-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 29815-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29815-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|