|
US$439.00 · In stock Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29323-2012: Specification for 1 000 kV circuit breaker protection equipment Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 29323-2012 | English | 439 |
Add to Cart
|
4 days [Need to translate]
|
Specification for 1 000 kV circuit breaker protection equipment
| Valid |
GB/T 29323-2012
|
PDF similar to GB/T 29323-2012
Basic data | Standard ID | GB/T 29323-2012 (GB/T29323-2012) | | Description (Translated English) | Specification for 1 000 kV circuit breaker protection equipment | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K45 | | Classification of International Standard | 29.240.99 | | Word Count Estimation | 19,161 | | Quoted Standard | GB/T 191; GB/T 2887-2011; GB/T 2900.17; GB/T 2900.49; GB/T 7261-2008; GB/T 9361-2011; GB/T 11287-2000; GB/T 14285-2006; GB/T 14537-1993; GB/T 14598.9-2010; GB/T 14598.10-2012; GB/T 14598.11-2011; GB/T 14598.13-2008; GB/T 14598.14-2010; GB/T 14598.16-2002; | | Regulation (derived from) | National Standards Bulletin No. 41 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the 1 000 kV double circuit breaker wiring or a half breaker breaker protection devices of the basic technical requirements, test methods, inspection rules and the logo, packaging, transportation and storage requirements. This stan |
GB/T 29323-2012: Specification for 1 000 kV circuit breaker protection equipment---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specification for 1 000 kV circuit breaker protection equipment
ICS 29.240.99
K45
National Standards of People's Republic of China
1000kV breaker protection Technical Requirements
Issued on. 2012-12-31
2013-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 2 Technical Requirements
Environmental Conditions 2 4.1
4.2 rated electrical parameters 3
4.3 Power consumption 3
The main function of the entire device 3 4.4
The main technical performance of the device 4 4.5
5 4.6 Overload
4.7 insulation 6
4.8 heat-resistant properties 6
4.9 EMC requirements 7
4.10 DC Power Supply Effect 8
4.11 static simulation, dynamic simulation 8
4.12 8 continuous power
4.13 Mechanical Properties 8
4.14 texture, appearance and other 9
5 Test methods 9
5.1 Test conditions 9
5.2 Technical Performance Test 9
5.3 Temperature Test 10
5.4 storage, transportation extreme ambient temperature test 10
10 5.5 Power consumption test
5.6 overload test 10
10 5.7 Insulation Test
5.8 Humidity Test 10
11 5.9 EMC requirements test
5.10 DC power impact test 12
5.11 continuous test 12
Mechanical test 12 5.12
Structure and appearance inspection 12 5.13
12 6 Inspection Rules
6.1 Inspection classification 12
6.2 factory inspection 12
13 6.3 Type inspection
7 signs, packaging, transportation and storage 14
7.1 marks 14
7.2 Packaging 14
7.3 Transport 14
7.4 Storage 14
8 Other 14
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national measuring relays and protection equipment Standardization Technical Committee (SAC/TC154) centralized.
This standard was drafted. National Electric Power Dispatching and Communication Center, State Grid Corporation of UHV Construction, NARI Relays Electric Co.
Secretary, State Grid Electric Power Research Institute, China Electric Power Research Institute, Beijing Sifang Automation Co., Ltd., Guodian Nanjing Automation Unit
Parts Co., XJ Electric Co., Ltd., Hubei Electric Power Dispatching and Communication Center, Research Institute of smart grid equipment Xuchang, Xuchang open
Cape Electric Testing Institute.
The main drafters of this standard. Liu, Zheng Yuping, Shen Jun, Dong will, Xu Zhenyu, Zhu Hong, Wang Yujie, Zhao Yan Feng, Yao Zhiqing, Yu Fei,
Liu, Li Zhiyong, YANG Hui-xia, Zhu Bin, Zhang Xiling.
1000kV breaker protection Technical Requirements
1 Scope
This standard specifies the basic technical requirements 1000kV a half or double breaker breaker breaker protection device wiring,
Test methods, inspection rules and to signs, packaging, transportation and storage requirements.
This standard applies to 1000kV double breaker or a microprocessor-based relay means half breaker breaker (hereinafter referred to as
For the device), such as a device based on the design, manufacture, testing and applications.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging - Pictorial signs
GB/T 2887-2011 General specification for computer sites
GB/T 2900.17 Electrotechnical terminology measuring relays
GB/T 2900.49 Electrotechnical terminology - Power System Protection
GB/T 7261-2008 Test Method for basic relay protection and automatic safety devices
GB/T 9361-2011 computer site security requirements
GB/T 11287-2000 Electrical relays - Part 21. Measuring relays and protection equipment vibration, shock, bump and seismic
Test Section 1. Vibration tests (sinusoidal)
GB/T 14285-2006 relaying protection and security automatic device technical regulations
GB/T 14537-1993 measure the impact of the collision with relays and protection equipment -
GB/T 14598.9-2010 metric Part 22-3 relays and protection equipment. Electrical disturbance tests anti-electromagnetic radiation
Degree of disturbance
GB/T 14598.10-2012 Electrical relays - Part 22-4. Electrical disturbance tests for measuring relays and electrical protection equipment
Fast transient/burst immunity test
GB/T 14598.11-2011 metric Part 11 relays and protection equipment. Auxiliary power port voltage dips, short interruptions,
Voltage and ripple
GB/T 14598.13-2008 Electrical relays - Part 22-1. Electrical disturbance tests measure relays and protection equipment
1MHz burst immunity test
GB/T 14598.14-2010 metric Part 22-2 relays and protection equipment. Electrical disturbance tests - Electrostatic discharge tests
GB/T 14598.16-2002 Electrical relays - Part 25. Electromagnetic emission tests for measuring relays and protection equipment
GB/T 14598.17-2005 Electrical relays - Part 22-6. Electrical disturbance tests for measuring relays and protection radio device
Frequency Field Immunity to conducted disturbances induced
GB/T 14598.18-2012 Electrical relays - Part 22-5. Electrical disturbance tests measure wave relays and protection equipment
Surge immunity test
GB/T 14598.19-2007 Electrical relays - Part 22-7. Electrical disturbance tests measure working relays and protection equipment
Frequency immunity tests
GB 14598.27-2008 metric Part 27 relays and protection equipment. Product safety requirements
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 29323-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 29323-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 29323-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 29323-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|