US$329.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 29179-2012: Fire emergency rescue -- Code of practice for operation Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 29179-2012 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Fire emergency rescue -- Code of practice for operation
| Valid |
GB/T 29179-2012
|
PDF similar to GB/T 29179-2012
Basic data | Standard ID | GB/T 29179-2012 (GB/T29179-2012) | | Description (Translated English) | Fire emergency rescue -- Code of practice for operation | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | C83 | | Classification of International Standard | 13.220.10 | | Word Count Estimation | 14,174 | | Quoted Standard | GB/T 5907; GB/T 29176 | | Regulation (derived from) | National Standards Bulletin 2012 No. 41; National Standards Commission recently released 16 national standards for fire protection | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the fire emergency rescue operations terms and definitions, as well as operating procedures and operating procedures. This standard applies to full-time fire brigade brigades and fire emergency rescue operations, fire and other eme |
GB/T 29179-2012: Fire emergency rescue -- Code of practice for operation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Fire emergency rescue. Code of practice for operation
ICS 13.220.10
C83
National Standards of People's Republic of China
Fire emergency rescue operations procedures
Issued on. 2012-12-31
2013-10-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by the People's Republic of China Ministry of Public Security.
This standard by the National Standardization Technical Committee fire fighting and rescue Technical Committee (SAC/TC113/SC10) centralized.
This standard was drafted. Shanghai Fire Research Institute of Ministry of Public Security.
The main drafters of this standard. Weihan Dong, Shi Wei, Wu Lizhi Wang Zhian, Zhu Qing, Lin Xue, Gao Ning Yu, Chen Yongsheng, Miao States Code, Li Guohui,
Jianglian Rui, Zhao Yihui, Deng Liang, Zhang Lei, Cao Yongqiang.
This standard is the first release.
Introduction
China's "Fire Act" provides that. public security fire brigade and the fire brigade to assume full-time major disasters and other rescue personnel in accordance with national regulations
Life-based emergency rescue work. According to relevant regulations of the State Council, the public security fire department is mainly responsible for earthquakes and other natural disasters, construction matter
Therefore, road traffic accidents, crash and other production safety accidents, terrorist attacks, the people in distress and other rescue mission social security incidents, as well as co
Help professional teams do about floods and droughts, meteorological, geological disasters, forest and grassland fires, biological hazards, accidents in mines, dangerous chemicals business
Therefore, water accidents, environmental pollution, nuclear and radiation accidents, public health emergencies such as rescue missions.
Emergency rescue the national standards mainly for public security fire brigade and the fire brigade to assume full-time natural disasters, production safety accident
And social safety incidents and other emergency rescue mission, and the current public security fire brigade and the fire brigade actual full-time commitment hazardous chemical accidents, water
Disaster, storms, landslides, water accidents, collapse of buildings and other rescue tasks developed with the aim to clarify the emergency rescue of the fire
Like, with specification fire emergency rescue equipment, training facilities, technical training, operating procedures and personnel qualifications, etc.
The contents of this standard are the job requirements of fire emergency procedures, mainly based on GB/T 29176 "Fire Emergency Rescue pass
The "proposed in the fire emergency rescue technology type formulation.
Fire emergency rescue operations procedures
1 Scope
This standard specifies the terms and definitions fire emergency rescue operations, as well as operating procedures and operating procedures.
This standard applies to full-time public security fire brigade and fire brigade fire emergency rescue operations, fire brigade and other emergency rescue teams can refer
carried out.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 5907 fire first part basic terms
GB/T 29176 General Emergency Rescue
3 Terms and Definitions
GB/T 5907, GB/T 29176 and defined by the following terms and definitions apply to this document.
3.1
Basic program basicprocedure
Fire emergency rescue operations during the implementation of a series of steps from the alarm turned out to clear the scene to evacuate.
3.2
Operating procedures codeofpracticeforoperation
Established for a particular specification fire emergency rescue procedures.
3.3
Anchor anchorpoint
Actual or potential for taking part in load rope rescue system.
3.4
Anchoring system anchorsystem
Consisting of one or more anchor system for providing structural connection of rope rescue system components.
3.5
Edge protection edgeprotection
Rope rescue system used to protect the soft parts from sharp objects or rough edges injury means or method.
4 Operating Procedures
4.1 Basic Program
Fire emergency rescue operations basic program comprising. detecting reconnaissance, evacuation warning, security, search and rescue personnel, danger exclusion, field
|