Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 26565-2011 | English | RFQ |
ASK
|
8 days [Need to translate]
|
Cementitious dry mix thermal insulation
| Obsolete |
GB/T 26565-2011
|
PDF similar to GB/T 26565-2011
Basic data Standard ID | GB/T 26565-2011 (GB/T26565-2011) | Description (Translated English) | Cementitious dry mix thermal insulation | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | Q25 | Classification of International Standard | 91.100.60 | Word Count Estimation | 56,519 | Date of Issue | 2011-06-16 | Date of Implementation | 2012-02-01 | Quoted Standard | GB/T 4132; GB/T 5464-1999; GB/T 5486; GB/T 6566; GB/T 8624-1997; GB/T 10294; GB/T 10295; GB/T 20473-2006; HJ/T 223; JG 158-2004; JGJ 70-2009 | Regulation (derived from) | Announcement of Newly Approved National Standards No. 9 of 2011 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | Summary | This standard specifies the adiabatic dry mixture of cement-based terminology and definitions, classifications, code and marking, technical requirements, test methods, inspection rules, packaging, labeling, transportation and storage. This standard applies to building insulation used with cement as the main binder dry mixture. |
GB/T 26565-2011: Cementitious dry mix thermal insulation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Cementitious dry mix thermal insulation
ICS 91.100.60
Q25
National Standards of People's Republic of China
Dry mixture of cement-based insulation
Issued on. 2011-06-16
2012-02-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
The standard proposed by China Building Materials Federation.
The standard insulation material by the National Standardization Technical Committee (SAC/TC191) centralized.
This standard is drafted by. China Building Material Test Certification Center.
Participated in the drafting of this standard. Zhejiang Huatai Sen building energy-saving Technology Co., Ltd., Beijing Science and Technology Development Co., Ltd. Qin days, Nanjing Overseas
Xing Environmental Equipment Co.
The main drafters of this standard. Liu Haibo, Zhang Yuhui, Chao Peng, Zhao enjoy Hong, Xu Hulin, Cao Fengying, Yang Feihua.
Dry mixture of cement-based insulation
1 Scope
This standard specifies the cement-based dry adiabatic mixing of terms and definitions, classifications, codes and labeling, technical requirements, test methods, inspection rules,
Packaging, labeling, transport and storage.
This standard applies to building insulation used as the main binder with cement dry blend.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 4132 insulation materials and related terms
GB/T 5464-1999 Test method for non-flammable building materials
GB/T 5486 inorganic rigid thermal insulation - Test methods
GB 6566 building materials radionuclide limits
GB 8624-1997 flammability of building materials classification method
GB/T 10294 insulation steady thermal resistance and related properties - Guarded hot plate method
GB/T 10295 insulation steady thermal resistance and related properties - Heat flow meter method
GB/T 20473-2006 building insulation mortar
HJ/T 223 environmental labeling products technical requirements for lightweight wall plate
JG158-2004 powder polystyrene particles exterior insulation and finish systems
JGJ70-2009 building mortar basic performance test method
3 Terms and Definitions
GB/T 4132 and identified the following terms and definitions apply to this document.
3.1
With cement as the main binder, mixed with light weight aggregate (for example. perlite, glass beads, etc.), and other additives made of dry material, use, proportionally
Example add water and stir molding insulation material.
4 classification and marking
4.1 Classification
Its dry density is divided into type Ⅰ, Ⅱ, Ⅲ type;
4.2 mark
Marked order. product name, model number and standard.
Example. dry density less than 300kg/m3 cement-based insulation dry mixture.
|