GB/T 25749.2-2010: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 2: Tracer gas method for the measurement of the emission rate of a given pollutant
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 25749.2-2010English194 Add to Cart 3 days [Need to translate] Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 2: Tracer gas method for the measurement of the emission rate of a given pollutant Valid GB/T 25749.2-2010

PDF similar to GB/T 25749.2-2010


Standard similar to GB/T 25749.2-2010

GB/T 23821   GB/T 26118.3   GB/T 26118.1   GB/T 25749.7   GB/T 25749.8   GB/T 25749.6   

Basic data

Standard ID GB/T 25749.2-2010 (GB/T25749.2-2010)
Description (Translated English) Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 2: Tracer gas method for the measurement of the emission rate of a given pollutant
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard J09
Classification of International Standard 13.110
Word Count Estimation 10,120
Date of Issue 2010-12-23
Date of Implementation 2011-10-01
Quoted Standard GB/T 15706.1-2007; GB/T 25749.1-2010
Adopted Standard ISO 29042-2-2009, IDT
Regulation (derived from) National Standard Approval Announcement 2010 No.10 (Total No.165)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the use of a tracer gas technique to measure in the operating state of a single machine controlled gaseous substance emission rate method. This section does not apply to the manufacture of machinery before its release.

GB/T 25749.2-2010: Safety of machinery -- Evaluation of the emission of airborne hazardous substances -- Part 2: Tracer gas method for the measurement of the emission rate of a given pollutant



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Safety of machinery Evaluation of the emission of airborne hazardous substances Part 2. Tracer gas method for the measurment of the emission rate of a given pollutant ICS 13.110 J09 National Standards of People's Republic of China Hazardous Substances Safety of machinery airborne Assessment of emissions - Part 2. Measuring a given pollutant Emission rate of tracer gas method airbornehazardoussubstances-Part 2. Tracergasmethodforthe (ISO 29042-2.2009, IDT) Issued on. 2010-12-23 2011-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Introduction Ⅲ Introduction Ⅳ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4 Principle 1 5 position of the machine 1 5.1 Overview 1 5.2 Method 1 indoor 5.3 Act 2 scene 6 Equipment and Materials 2 7 measuring point 3 8 Program 3 9 Data Analysis 4 Expression of results 10 4 11 Test Report 5

Foreword

GB/T 25749 "assessment of emissions of harmful substances airborne machinery safety" by the following nine components. Selection of test methods. --- Part 1 --- Part 2. Measuring the emission rate of a given pollutant tracer gas method --- Part 3. Measuring the rate of a given pollutant emission test bench method --- Part 4. capture efficiency of an exhaust system measuring tracer method --- Part 5. Measurement of air purification system without conduit outlet mass separation efficiency, test bench method --- Part 6. Measuring the quality of the separation efficiency air purification system with duct outlet, test bench method --- Part 7. measurement of pollutant concentrations, test bench method --- Part 8. Measuring the concentration of pollutants in indoor law --- Part 9. Purification Index This part of GB/T 25749 Part 2. This part identical with ISO 29042-2.2009 "Safety of machinery - Assessment airborne emissions of harmful substances - Part 2. Measurement Given pollutant emission rate of tracer gas method "(in English). This section is equivalent translation ISO 29042-2.2009. For ease of use, this section made the following editorial changes. --- Deleted the ISO foreword, preface rewritten; --- Delete the contents of the introduction of international standards on ISO /TC199 scope of work; --- Remove the contents of the introduction of international standards on the relationship with the international standards of the European standard; --- The Lead Normative documents according to GB/T 1.1-2009 modified and ISO 29042-2.2009 references country Corresponding to international standards to national standards; --- 6.6 column item number changed to "a), b), c), d), e)". This part of the National Safety Standardization Technical Committee (SAC/TC208) and focal points. This section is drafted. Mechanical Science Research Institute, Shenzhen City, measuring Detection Technology Co., Ltd., a limited LiuGong The company, Nanjing Forestry University Institute of Engineering electromechanical meter. The main drafters of this section. Fu Dawei, Li Qin, Yan Ning, Zhu Ping, home glory, Lin JR, Fu Rui, Zhang Xiaofei, Wu Guangyuan, Wangxi Wei, Huang Zhongliang, Song Xiaoning, Liu Zhiyong.

Introduction

Machinery safety standard is structured as follows. --- A class standard (basic safety standards) give basic concepts apply to all mechanical, design principles and general characteristics. --- B class standard (generic safety standards), covering the mechanical characteristics of a safe or use a wider class of safety devices. ● B1 class, specific security features (e.g., safety distance, surface temperature, noise) standard; ● B2 class, the safety device (such as a hand control devices, interlocking devices, pressure sensitive devices, guards). --- C class standards (machine safety standards), for a particular machine or group of machines shall specify detailed safety standard requirements. According to GB/T 15706.1, this section is a Class B standards. Provisions of this section may be supplemented or modified by the C standard. For Class C in accordance with the standard design and construction of the machine, if the C class standards in terms of Class A or Class B standards are inconsistent, priority Using C standard. Hazardous Substances Safety of machinery airborne Assessment of emissions - Part 2. Measuring a given pollutant Emission rate of tracer gas method

1 Scope

This section GB/T 25749 specifies the method of using tracer gas measurement technology in the operating state of a single machine controlled gaseous substance The method of emission rate. This section does not apply to the manufacture of machinery prior to its release.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 15706.1-2007 Safety of machinery - Basic concepts, general principles for design - Part 1. Basic terminology, methodology (ISO 12100-1.2003, IDT) Select test method. GB/T 25749.1-2010 Safety of machinery - Assessment airborne emissions of harmful substances - Part 1 (ISO 29042-1.2008, IDT)

3 Terms and Definitions

GB/T 15706.1-2007 and GB/T 25749.1 defined and the following terms and definitions apply to this document. 3.1 Tracer gas technology tracergastechnique Use the aerodynamic properties of gaseous harmful substances considered similar and gaseous substance technology concentration can be measured reliably. Principle 4 This principle is based on the tracer gas in order to adopt a known constant emission rate as the best representation of generating sources. And tracer gas The average concentration of pollutants measured in the vicinity of emission sources. Assuming that contaminants aerodynamics with the same tracer gas, sewage can be determined Dye emission rate thereof.

5 position of the machine

5.1 Overview This method is intended for laboratory or field is located in the machine. 5.2 Indoor law Overall airflow pattern features the laboratory should be able to achieve more precise control of the general and local ventilation. The machine should be placed in a laboratory