|
US$1014.00 · In stock Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 25444.2-2010: Mobile and fixed offshore units -- Electrical installations -- Part 2: System design Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 25444.2-2010 | English | 1014 |
Add to Cart
|
6 days [Need to translate]
|
Mobile and fixed offshore units -- Electrical installations -- Part 2: System design
| Valid |
GB/T 25444.2-2010
|
Standard similar to GB/T 25444.2-2010 GB/T 25444.5 GB/T 25444.6 GB/T 25444.3
Basic data | Standard ID | GB/T 25444.2-2010 (GB/T25444.2-2010) | | Description (Translated English) | Mobile and fixed offshore units -- Electrical installations -- Part 2: System design | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | U60 | | Classification of International Standard | 47.020.60 | | Word Count Estimation | 51,539 | | Date of Issue | 2010-11-10 | | Date of Implementation | 2011-05-01 | | Quoted Standard | GB/T 4205; GB/T 6994-2006; GB/T 10250; GB/T 18039.4; GB/T 20438.1; GB/T 20438.2; GB/T 20438.3; GB/T 20438.4; GB/T 20438.5; GB/T 20438.6; GB/T 20438.7; GB/T 21109.1; GB/T 21109.2; GB/T 21109.3; GB/T 25444.3; GB/T 25444.5-2010; IEC 60038-2002; IEC 60092-504-2001; IEC 60617-DB-2001; IEC 60947-2-2003; IEC 61892-1-2001; IEC 61892-7-1997; IEC 62271-100; SOLAS SOLAS Convention; IMO MODU rules-1989 | | Adopted Standard | IEC 61892-2-2005, IDT | | Regulation (derived from) | National Standard Approval Announcement 2010 No.8 (Total No.163) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the system design requirements of mobile and fixed offshore facilities electrical installations. Applicable to offshore oil drilling industry, production, processing and storage, including pipeline, within the pumping station or tube cleaning station, compressor stations and exposed single buoy mooring facilities. This section does not apply to more than 35000 V AC voltage and DC voltage not exceeding 750V permanent, temporary, All mobile or hand-held electrical device. This section does not apply to fixed electrical installations or medical equipment on tankers. |
GB/T 25444.2-2010: Mobile and fixed offshore units -- Electrical installations -- Part 2: System design ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Mobile and fixed offshore units Electrical installations Part 2. System design
ICS 47.020.60
U60
National Standards of People's Republic of China
Mobile and fixed offshore facilities
System Design. Part 2 electrical installations
Part 2. Systemdesign
(IEC 61892-2.2005, IDT)
Issued on. 2010-11-10
2011-05-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅴ
1 Scope 1
2 Normative references 1
3 Terms and definitions 2
4 Power 6
4.1 General 6
4.2 Main Power 6
4.3 Emergency power supply 7
4.4 periodically unattended machinery spaces Additional requirements 7
4.5 General provisions renewable power source 8
Arrangement and location 8 4.6
4.7 Output 9
4.8 Additional emergency electrical power system of claim 9
Start emergency generator set 10 4.9
5 System ground 10
5.1 General 10
10 5.2 General Requirements
5.3 neutral grounding method 10
Neutral grounding system 5.4 1000V and below 11
Grounded neutral system of more than 5.5 1000V 11
5.6 and power transformer parallel operation of generators 11
5.7 connected to the grounding resistance housing/structure 11
6 Distribution System 12
6.1 DC power distribution system 12
6.2 AC power distribution system 16
Distribution system 20 of claim 7
7.1 grounding distribution system 20
7.2 Distribution 21
7.3 Load Balancing 21
7.4 Finally, the branch circuit 21
7.5 control circuit 21
7.6 socket 22
7.7 mobile offshore shore power connection facility 22
7.8 motor circuit 22
8 is not the same (demand) coefficient 23
8.1 Finally, the branch circuit 23
8.2 Finally, the non-branch circuit 23
8.3 is not the same application (demand) coefficient of 23
8.4 General requirements for the driving circuit --- 23
9 System analysis and calculations 23
9.1 General 23
9.2 Electrical Load Analysis 24
9.3 Flow Calculation 24
Short circuit calculation 24 9.4
9.5 Analysis of protection and coordination 26
9.6 Calculation of the dynamic power system 26
9.7 Calculation of harmonic currents and voltages 27
10 protection 27
10.1 General 27
10.2 rating and short circuit protection of electrical-related features and options 28
10.3 and overload protection of electrical-related choices 29
10.4 relating to the application of the protective devices Selection 29
10.5 undervoltage protection 30
10.6 Overvoltage protection 31
Lighting 11 31
11.1 General 31
General lighting system 31 11.2
Emergency lighting system 32 11.3
11.4 escape lighting systems 33
11.5 machinery spaces, accommodation spaces and open deck spaces such as lighting circuit 34
34 11.6 Lamps
34 12 Control and instrumentation
Safety measures 34 12.1
12.2 supply arrangements 34
34 12.3 trustworthiness
35 12.4 Security
12.5 Isolation 35
12.6 Performance 35
12.7 integration 35
12.8 Development Activities 35
12.9 Electromagnetic Compatibility 35
12.10 Design 35
12.11 Installation and Ergonomics 36
12.12 standardization install 36
Automatic power control devices 12.13 37
12.14 motor control device 39
12.15 public broadcasting and full alarm system 39
12.16 39 Computer System
Software 12.17 41
12.18 Test 43
12.19 43,
43 13 Enclosure rating
13.1 General 43
References 45
Power 1 BC/electrical continuity 6
2 TN-S system Figure 13 DC
Figure 3 TN-C system, DC 14
Figure 4 TN-CS dc system 15
Figure 5 IT DC system 16
Figure 6 TN-S AC system 17
7 TN-CS system AC 18
8 TN-C system AC 18
9 IT AC systems 19
Table 1 Main characteristics of neutral grounding Summary 11
Table 2 DC system voltage 16
Table 3 AC system or related device 19 having a nominal voltage of 100V ~ 1000V
Table 4 has a three-phase AC system the following nominal voltage 1kV ~ 35kV or related equipment 20
Table 5 general lighting illuminance level 31
Table 6 escape lighting illuminance level 33
Table 7 mobile and fixed offshore facilities protection class minimum requirements 44
Foreword
GB/T 25444 "mobile and fixed offshore installations electrical devices" is divided into seven sections.
--- Part 1. General requirements and conditions;
--- Part 2. system design;
--- Part 3. equipment;
--- Part 4. Cable;
--- Part 5. mobile facilities;
--- Part 6. Installation;
--- Part 7. Hazardous area.
This section GB/T 25444 Part 2.
This section identical with IEC 61892-2.2005 "the second part of the mobile and fixed offshore installations Electrical installations. System Design"
(In English).
For ease of use, this section made the following editorial changes.
a) "This part of IEC 61892" be replaced by "GB/T 25444 this part" or "this part";
b) For IEC 61892-2.2005 international standard references, there is equated adopted as our standard, and in this section by reference
Our standard instead of an international standard, not identical with the rest of our standards in this section are referenced directly;
c) use a decimal point instead of a comma as the decimal point, '' '';
d) Remove international standards preface, introduction;
e) presentation of in accordance with the provisions of GB/T 1.1-2000 also been modified;
f) the provisions of the footnotes in this section are numbered sequentially.
This part is proposed by the China State Shipbuilding Corporation.
This part of the National Standardization Technical Committee Marine Boats (SAC/TC12/SC6) centralized.
This section drafted by. China Shipbuilding Technology and Economy Research Institute.
The main drafters of this section. Yan Ping.
Mobile and fixed offshore facilities
System Design. Part 2 electrical installations
1 Scope
GB/T 25444 in this section (hereinafter referred to in this section) provides design system for mobile and fixed offshore installations to the electrical device
Demand for offshore oil industry, drilling, production, processing and storage, including the pipeline, pumping stations or inner tube cleaning station, compressor station and the exposed single
Buoy mooring facilities.
This section applies to not more than 35000V AC voltage and DC voltage not exceeding 750V permanent, temporary, mobile or handheld
All electrical installations (AC and DC voltage of nominal voltage).
This section does not apply to fixed electrical installations or medical equipment on tankers.
2 Normative references
The following documents contain provisions which, through reference GB/T 25444 in this section constitute provisions of this section. For dated reference documents
Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section
Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this
section.
GB/T 4205 man-machine interface (MMI) operating rules (GB/T 4205-2003, IEC 60447.1993, IDT)
GB/T 6994-2006 marine electrical equipment definitions and general provisions (IEC 60092-101.2002, IDT)
GB/T 10250 Marine Electrical and electronic equipment electromagnetic compatibility (GB/T 10250-2007, IEC 60533.1999, IDT)
GB/T 18039.4 Electromagnetic compatibility environment facility frequency conducted disturbances compatibility level (GB/T 18039.4-2003,
IEC 61000-2-4.1994, IDT)
GB/T 20438 functional safety (all parts), electrical/electronic/programmable electronic safety-related systems [GB/T 20438 (all section
Points) -2006, IEC 61508 (all parts), IDT]
Functional safety GB/T 21109 (all parts) process industry Safety Instrumented System [GB/T 21109 (all parts) -
2007, IEC 61511 (all parts).2003, IDT]
GB/T 25444.3 - Part 3 mobile and fixed offshore installations Electrical installations. equipment (GB/T 25444.3-2010,
IEC 61892-3.2007, IDT)
GB/T 25444.5-2010 mobile and fixed offshore installations electrical installations - Part 5. Mobile Facilities (IEC 61892-
5.2000, IDT)
IEC 60038.2002 International Electrotechnical Commission standard voltage (IEC standardvoltages)
IEC 60092-504.2001 marine electrical equipment Part 504. album Control and instrumentation (Electrical
instalationsinships-Part 504. Specialfeatures-Controlandinstrumentation)
IEC 60617-DB.20011) Graphic chart symbols and architecture topographical installation plans and charts (Graphical
symbolsfordiagrams-Architecturalandtopographicalinstalationplansanddiagrams)
1) "DB" IEC reference online database.
IEC 60947-2.2003 Low-voltage switchgear and control equipment Part 2. Circuit Breaker (Lowvoltageswitchgear
andcontrolgear-Part 2. Circuit-breakers)
IEC 61892-1.2001 Part 1 mobile and fixed offshore installations Electrical installations. General requirements and conditions (Mobile
andfixedoffshoreunits-Electricalinstaltions-Part 1. Generalrequirementsandconditions)
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 25444.2-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 25444.2-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 25444.2-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 25444.2-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|