GB/T 15447-2008: Conversion method of absorbed doses in different materials irradiated by X, γ rays and election beams
Status: Valid

GB/T 15447: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15447-2008English529 Add to Cart 4 days [Need to translate] Conversion method of absorbed doses in different materials irradiated by X, γ rays and election beams Valid GB/T 15447-2008
GB/T 15447-1995EnglishRFQ ASK 6 days [Need to translate] Conversion method of absorbed doses in different materials irradiated by X, γ rays and electron beams Obsolete GB/T 15447-1995

PDF similar to GB/T 15447-2008


Standard similar to GB/T 15447-2008

JJF 1234   JJG 188   GB/T 14365   GB/T 25439   GB/T 15053   GB/T 15446   

Basic data

Standard ID GB/T 15447-2008 (GB/T15447-2008)
Description (Translated English) Conversion method of absorbed doses in different materials irradiated by X, �� rays and election beams
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard A58
Classification of International Standard 17.240
Word Count Estimation 23,261
Date of Issue 2008-09-19
Date of Implementation 2009-08-01
Older Standard (superseded by this standard) GB/T 15447-1995
Regulation (derived from) Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the X, �� radiation and electron beam irradiation, according to the characteristics of the radiation field, the material composition and related measurements, a material known from another material absorbed dose absorbed dose calculation method. Scope of this standard: a) X, �� radiation photon energy range: 0. 01 MeV ~ 20 MeV, b) electron beam energy range

GB/T 15447-2008: Conversion method of absorbed doses in different materials irradiated by X, γ rays and election beams


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Conversion method of absorbed doses in different materials irradiated by X, γ rays and election beams ICS 17.240 A58 National Standards of People's Republic of China Replacing GB/T 15447-1995 X, γ-ray and electron beam irradiation of different materials Conversion method of absorbed dose Posted 2008-09-19 2009-08-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 4. Significance and Use 4 5 absorbed dose algorithm 5 6 values \u200b\u200bcalculated by the absorbent material A material B measured absorbed dose 5 7-ray mass energy absorption coefficient ratio method 6 8 under electron beam irradiation dose absorbed material conversion between 7 Accuracy 8 9 Appendix A (informative) charged particle equilibrium thickness 9 Absorption under Annex B (informative) wide spectrum beam dose calculation example 10 Annex C (informative) rays decreased 14 Annex D (informative) of formula (3) is proved 15 Annex E (informative) dose calculation 16 Annex F (informative) near the single photon energy spectrum absorbed dose conversion example 17 Appendix G (Informative Appendix) 0.1MeV ~ 10MeV electron beam in a certain range of the material of the actual Rp 18 References 19

Foreword

This standard reference ASTM E666.2003 "computing γ or X-ray absorption dose with standard practice" (in English). among them Chapters 7 and 8 with reference to ISO /ASTM51261.2002 "Guide for the selection and application of food irradiation processing dose measurement system is" (English version) and ISO /ASTM51649.2005 "energy of 300keV ~ 25MeV electron beam radiation processing dosimetry standard practice" (In English). This standard replaces GB/T 15447-1995 "X, conversion method γ-ray and electron beam irradiation of different materials absorbed dose." This standard and GB/T 15447-1995 compared to the main changes are as follows. --- According to ASTM standards, increase the "meaning and purpose" section (edition 4.1 and 4.2); --- According to ASTM standards, the original standard Chapter 5 "X, γ-ray energy fluence integral calculation" decomposition edition Chapter 5 "suck Received doses of Algorithms "and Chapter 6," absorbed dose calculated by the measured material A material B absorbed dose "(see 1995 edition Chapter 5;, Chapter 6 edition Chapter 5); --- According to the ASTM standard, in Chapter 6 increases the formula to calculate the absorbed dose of radiation suitably narrow beam, identified in the calculation of the absorption Dose reduced coefficient expressions of photons with a suitable narrow beam radiation, energy reduced coefficient suitable wide-beam radiation (see Excerpts Chapter 6); --- Increase the informative Appendix C "Ray weakened" (see this edition Appendix C); --- Increase the informative Appendix D "formula (3) is proved" (see this edition Appendix D); --- Increase the informative Appendix E "dose calculation" (see this edition Appendix E); --- There are some editorial changes. The Standard Appendix A, Appendix B, Appendix C, Appendix D, Appendix E, Appendix F and Appendix G is an informative annex. The standard proposed by China National Nuclear Corporation. This standard by the National Standardization Technical Committee of nuclear energy. This standard was drafted. China Institute of Metrology. The main drafters. Zhang Yanli, Guo Bin, Liu Zhi Mian, Fancheng, Lvya bamboo. This standard replaces the standards previously issued as follows. --- GB/T 15447-1995. X, γ-ray and electron beam irradiation of different materials Report No. ICRU60 basic Ionizing Radiation Quantities and Units

3 Terms and Definitions

GB/T 15446 and ICRU Report No. 60 and established the following terms and definitions apply to this standard. 3.1 Yan E d d m1 obtained by dividing the quotient, namely

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15447-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15447-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15447-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15447-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15447-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15447-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.