US$279.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24895-2010: Inspection of grain and oils -- General regulations for model authentication of near-infrared analysis and administration and maintenance of network Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24895-2010 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Inspection of grain and oils -- General regulations for model authentication of near-infrared analysis and administration and maintenance of network
| Valid |
GB/T 24895-2010
|
PDF similar to GB/T 24895-2010
Basic data | Standard ID | GB/T 24895-2010 (GB/T24895-2010) | | Description (Translated English) | Inspection of grain and oils -- General regulations for model authentication of near-infrared analysis and administration and maintenance of network | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | B20 | | Classification of International Standard | 67.060 | | Word Count Estimation | 12,171 | | Date of Issue | 2010-06-30 | | Date of Implementation | 2011-01-01 | | Quoted Standard | GB/T 4091; GB/T 5009.9; GB 5491; GB/T 5497; GB/T 5505; GB/T 5511; GB/T 5512; GB/T 14488.1; GB/T 14489.2; GB/T 15000.5; GB/T 27025 | | Regulation (derived from) | National Standard Approval Announcement 2010 No.2 (Total No.157) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the Agri- NIR analyzer calibration model validation and network management and maintenance of terminology and definitions, basic requirements of near-infrared analyzer, scaling model validation and evaluation, calibration model transfer and evaluation, instruments and calibration model was built files, instrument daily monitoring, network management and maintenance requirements. This standard applies to Agri- NIR analyzer calibration model validation and near-infrared analysis of network management and maintenance. |
GB/T 24895-2010: Inspection of grain and oils -- General regulations for model authentication of near-infrared analysis and administration and maintenance of network ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Inspection of grain and oils. General regulations for model authentication of near-infrared analysis and administration and maintenance of network
ICS 67.060
B20
National Standards of People's Republic of China
Inspection of grain NIR calibration model validation and
Network management and maintenance of general rules
Issued on. 2010-06-30
2011-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The Standard Annexes A and B are normative appendix.
The standard proposed by the National Food Authority.
This standard by the National Standardization Technical Committee OILS.
This standard is drafted by. National Food Authority Standard Quality Center, Henan University of Technology.
Participated in the drafting of this standard. Henan Cereals, Oils and feed products Supervision, Inspection Station, Hubei Province Cereals, Oils and food quality monitoring stations, Jilin Grain and Oil Quality
Amount detection station, Fox Analytical Instruments, Perten Instruments.
The main drafters of this standard. Zheng Du, Tang Ruiming, Long Lingli, Zhu light, Wu Chun-rong, Huai Tang Jian, Zhou Zhanming, Yin Chenghua, bears Ning, Fengxi Zhong,
Zhao Wushan, Liu Yufei.
Inspection of grain NIR calibration model validation and
Network management and maintenance of general rules
1 Scope
This standard specifies OILS NIR calibration model validation and network management and maintenance terms and definitions, based near-infrared analyzer
This requirement, model validation and calibration evaluation, calibration models transfer and evaluation instruments and calibration models archiving, daily monitoring equipment, network management and
Maintenance requirements.
This standard applies to grain and oil NIR analyzer calibration model validation and near-infrared analysis of network management and maintenance.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 4091 General Control Charts
Determination of GB/T 5009.9 food starch
GB 5491 grain and oilseeds testing for sampling, and sample method
GB/T 5497 grain and oilseeds - Determination of water test
GB/T 5505 Inspection of grain - Determination of ash
GB/T 5511 Cereals and pulses - Determination of nitrogen content and calculation of crude protein content Kjeldahl method
GB/T 5512 Inspection of grain and grain Determination of fat content
GB/T 14488.1 Determination of oil content of oil plants
Determination of GB/T 14489.2 Inspection of grain and oil plant crude protein
GB/T 15000.5 standard for the work of (5) the chemical composition of Technologic rules
GB/T 27025 testing and calibration laboratories General requirements
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
A modem, the Internet or other means of near-infrared and near-infrared handset hosts connected into a whole grain and oil quality
Quantitative Analysis System. Through the implementation of near-infrared host calibration model validation, model calibration is transferred to slave and near-infrared instrument stability routine monitoring
Etc., to ensure that each instrument network analysis, measurement accuracy and consistency of results.
3.2
Based on the absorption characteristics of the near-infrared region of the spectrum of grain and oil sample measurement component content of grain and oil and its products (such as moisture, fat, protein, starch
Analytical instruments dedicated powder, crude fiber) or characteristic indicators.
3.3
The use of chemometric methods to establish the sample near-infrared spectroscopy and chemical correspondence between the value of standard mathematical models.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24895-2010_English be delivered?Answer: Upon your order, we will start to translate GB/T 24895-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24895-2010_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24895-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|