US$294.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 24626-2009: Explosion resistant equipment Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 24626-2009 | English | 294 |
Add to Cart
|
3 days [Need to translate]
|
Explosion resistant equipment
| Valid |
GB/T 24626-2009
|
PDF similar to GB/T 24626-2009
Basic data | Standard ID | GB/T 24626-2009 (GB/T24626-2009) | | Description (Translated English) | Explosion resistant equipment | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K35 | | Classification of International Standard | 29.260.20 | | Word Count Estimation | 15,159 | | Date of Issue | 2009-11-30 | | Date of Implementation | 2010-04-01 | | Quoted Standard | EN 13980; EN 13445-4; EN 13445-3; EN 13445-2; EN 13445-1; EN 10204; EN 1092-1; GB/T 19001; GB/T 2900.35; GB/T 228 | | Adopted Standard | EN 14460-2006, IDT | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 13 of 2009 (No. 153 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the explosion pressure resistant explosion pressure shock resistant and equipment requirements. This standard applies to the process of resistance to explosive devices and systems. Does not apply to individual parts of equipment such as motors, gearboxes, etc. These parts can be designed to meet the non-electrical equipment for explosive atmospheres flameproof enclosure type "d" requirements for the structure to withstand an internal explosion. This standard applies to the environmental conditions: atmospheric pressure range 0. 08MPa ~ O. 11MPa, a temperature range of -20��C ~ +60��C. This standard environment outside the range of the effective use of the equipment design, manufacture, inspection and marking also help, provided that such equipment is no specific standard requirements. This standard applies to possible deflagration devices and device combinations, does not apply to possible detonation devices and device combinations. This standard can not be used for offshore facilities. |
GB/T 24626-2009: Explosion resistant equipment---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Explosion resistant equipment
ICS 29.260.20
K35
National Standards of People's Republic of China
Explosion resistant equipment
Posted 2009-11-30
2010-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 explosion-resistant equipment requirements 2
5 explosion pressure resistant design 3
6 explosion pressure shock resistant design 3
Quality documents explosion-resistant equipment 6 7
8 use of information 6
Appendix A (normative) Calculation of the design pressure of 8
Annex B (informative) limit stress concentration Example 9
Foreword
This standard is a reference to EN14460.2006 "anti-explosive devices" (in English) to develop, the technical content is equivalent to using the standard.
Appendix A of this standard is a normative appendix, Appendix B is an informative annex.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national explosion-proof electrical equipment Standardization Technical Committee (SAC/TC9) centralized and explain.
This standard is mainly drafted by. Nanyang Explosion Electric Institute, the national explosion-proof electrical products for Quality Supervision and Inspection Center, coal scientific research
General Hospital Shanghai Branch blast Electric Co., Ltd.
The main drafters. Zhang Gang, Maqiu Ju, Liu Yun, Zhang Xian force, Li Bin, Li Shu Dynasty, Liu Sijing.
Introduction
Complete explosion safety measures include the following points principles and manufacturers must be taken.
a) prevent the formation of explosive atmospheres;
b) to prevent the ignition of explosive environment; and
c) If you still exploded, immediately stop and/or explosion flames and explosion pressures to limit the scope of a sufficient level of safety.
If the ignition hazard assessment shows that the equipment can not meet the level requirements specified purpose equipment required (for example, adopted in accordance with the "explosive
Ignition protection type of ignition source prevention), you need to take c) above method environment with non-electrical equipment "series of standard definition. The standard gauge
Given the explosion-resistant equipment. It is a term used in the explosion-resistant housing structure, indicating that it can withstand the expected explosion pressure without rupture.
Device has this feature, you can scope explosion flames and explosion pressure limit adequate security levels.
This "anti-explosion" feature can be used for equipment, protective systems and components.
Explosion resistant equipment
1 Scope
This standard specifies the requirements for explosion pressure resistant and explosion pressure shock resistant device.
This standard applies to the process of anti-explosive devices and systems. Not a single part for a device such as motors, gearboxes, etc., which
These can be designed as part of the structure in line with non-electrical equipment for explosive atmospheres flameproof enclosure type "d" requirement, it can withstand an internal explosion.
This standard applies to the environmental conditions. atmospheric pressure in the range of 0.08MPa ~ 0.11MPa, temperature range of -20 ℃ ~ + 60 ℃.
The standard for the design, manufacture, inspection and marking outside of the effective range of the device used in an environment also help, provided that such a set
Preparation no specific standards.
This standard applies to devices and device combinations may occur knocking does not apply to devices and device combinations may occur detonation. The standard
Registration is not available for offshore installations.
NOTE. This standard applies only to devices made of a metal material.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 228 indoor metallic materials - Tensile testing (GB/T 228-2002, eqvISO 6892.1998)
GB/T 2900.35 Electrotechnical terminology - Electrical equipment for explosive atmospheres (GB/T 2900.35-2008, IEC 60050-426.2008,
IDT)
GB/T 19001 quality management system requirements (GB/T 19001-2008, ISO 9001.2008, IDT)
EN1092-1 Flanges and their joints, fittings, valves, fittings and accessories with circular shaped flanges - Part 1. PN designated steel
Flange system
Types of inspection documents EN10204 metal products
EN13445-1 non-direct contact with the flame pressure vessels - Part 1. Overview
EN13445-2 non-direct contact with the flame pressure vessels - Part 2. Materials
Non-direct contact EN13445-3 flame pressure vessels - Part 3. Design
EN13445-4 non-direct contact with the flame pressure vessels - Part 4. Manufacturing
Application of EN13980 quality system in potentially explosive atmospheres
3 Terms and Definitions
GB/T 2900.35, and established the following terms and definitions apply to this standard.
3.1
Subsonic explosion propagation.
3.2
Supersonic shock wave propagation and explosion having characteristics.
3.3
Lead to higher temperatures and/or vigorous oxidation reaction or decomposition reaction pressure increases.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 24626-2009_English be delivered?Answer: Upon your order, we will start to translate GB/T 24626-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 24626-2009_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 24626-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|