US$194.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 22148.2-2014: Test method on electromagnetic emissions -- Part 2: Electronic control gear for discharge lamps excluding fluorescent lamps Status: Valid
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 22148.2-2014 | English | 194 |
Add to Cart
|
3 days [Need to translate]
|
Test method on electromagnetic emissions -- Part 2: Electronic control gear for discharge lamps excluding fluorescent lamps
| Valid |
GB/T 22148.2-2014
|
PDF similar to GB/T 22148.2-2014
Basic data | Standard ID | GB/T 22148.2-2014 (GB/T22148.2-2014) | | Description (Translated English) | Test method on electromagnetic emissions -- Part 2: Electronic control gear for discharge lamps excluding fluorescent lamps | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L06 | | Classification of International Standard | 33.100 | | Word Count Estimation | 10,116 | | Date of Issue | 12/12/2014 | | Date of Implementation | 6/1/2015 | | Quoted Standard | GB 17743-2007; CISPR 15-2006; CISPR 15-2008 | | Adopted Standard | CISPR/TR 30-2-2012, IDT | | Regulation (derived from) | National Standards Bulletin 2014 No. 30 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard provides for an independent test for class I and/or Class �� discharge lamps (excluding fluorescent lamps) luminaires with built-in electronic control unit of radio disturbance characteristics. This standard applies to the output power (lamp |
GB/T 22148.2-2014: Test method on electromagnetic emissions -- Part 2: Electronic control gear for discharge lamps excluding fluorescent lamps ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Standard Test Method for electromagnetic emissions Part 2. Discharge lamps (excluding fluorescent lamps) electronic control device)
ICS 33.100
L06
National Standards of People's Republic of China
Electromagnetic emission test methods - Part 2.
Discharge lamps (excluding fluorescent lamps) electronic control unit
Testmethodonelectromagneticemissions-Part 2. Electroniccontrolgearfor
(CISPR/T R30-2.2012, IDT)
Issued on. 2014-12-22
2015-06-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
Introduction Ⅳ
1 Scope 1
2 Normative references 1
3 to determine compliance 1
4 Test Method 1
5 Baseline lamps 1
5.1 Structure 1
5.2 Installation and wiring arrangement 2
Ground 2 5.3
5.4 Wiring 2
6 3 logo
7 Luminaire Design Guide 3
Appendix A (informative) Installation and wiring layout 4
Foreword
GB/T 22148 "Standard Test Method for electromagnetic emissions" contains the following sections.
--- Part 1. single-ended and double-ended fluorescent lamps with electronic control unit;
--- Part 2. discharge lamps (excluding fluorescent lamps) electronic control unit.
This part of GB/T 22148 Part 2.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section uses the translation method identical with CISPR/T R30-2.2012 (Version 1.0) "Test methods for electromagnetic emissions - Part 2. Put
Lamps (excluding fluorescent lamps) electronic control unit, "the technical content completely identical with CISPR/T R30-2.2012, in line with Chinese language
Language habits, budgeting format with CISPR/T R30-2.2012 agreement.
Consistency correspondence between this part of international documents and normative references of our files are as follows.
--- GB 17743-2007 Limits and methods of measurement of electrical lighting and similar equipment - Radio disturbance characteristics (CISPR
15.2005, IDT).
This part of the National Standardization Technical Committee on Radio Interference (SAC/TC79) and focal points.
This section drafted by. China Electric Apparatus Research Institute Co., Ltd., Dongguan, Guangdong Province Quality Supervision and Inspection Center, CVC detection technology
Ltd, Midea Group Co., Ltd., Chinese Academy of household appliances, light Shanghai era lighting electrical testing Limited, Beijing Terrett
Detection Technology Services Co., Ltd., Zhejiang Sunshine Lighting & Electrical Group Co., Ltd., Foshan City, China Electrical Lighting Co., Ltd.
The main drafters of this section. Yang Chunrong, Jiaming Hui, Tang Chun Yong, Ji Tao Li Xiuqing, Liu Li Er, had Bo, Li Yan, Huo Hongyan, Chen Ping,
Cooper rights.
Introduction
CISPR15.2005 clearly defines the radio frequency disturbance limits lighting requirements, but only regarded as finished and scheduled to run
Lighting equipment end-user market and make provision, for example, lamps, self-ballasted fluorescent lamps and stand-alone electronic control device. Intend to install
No part in the fixture emission requirements.
Discharge lamp, the electronic control device, not only is installed in a different manufacturer's lamps, it is installed in the same factory and different types
Fixtures.
Although the data can predict some type of harassment in other lighting fixtures measured with the same electronic control unit and lamp, but the
These lamps should still be tested.
This begs the question, we can design a test fixture for the worst-case installation test electronic control device, in this case
Under conditions of the test lamps meet the requirements, then the contents of the electronic control unit for all lamps meet the requirements, you can avoid a lot of unnecessary
Test. The idea seems to be correct, simple and fun, but it leads to two opinions.
Lamps --- worst case too strict. Discovery of lamps installed in the worst case can not be certain of the test from the forecast,
In actual lamps through;
--- Even if the electronic control unit mounted on the fixture in the worst case by the trial, there is still a problem, if the electronic control
Means mounted within the actual lighting does not meet the requirements, who will be responsible.
It is not appropriate to change CISPR15.2005 Basic Principles on the built-in lighting means no emission requirements.
However, within the radio spectrum must have a unique test to detect electronic control device performance.
Electronic control unit specific type of test fixture arrangement. This format is published separately to facilitate future revisions and modifications. When you need
Time, will increase the corresponding additional requirements.
Lamps.
Electromagnetic emission test methods - Part 2.
Discharge lamps (excluding fluorescent lamps) electronic control unit
1 Scope
GB/T his part of the CISPR15 T 22148.2005 requirements, corresponding to the reference on the basis of the use of the lamps, a detailed description
Ⅰ class and/or class Ⅱ discharge lamps (excluding fluorescent lamps) Lamps independent experiments for radio disturbance characteristics of devices with built-in electronic control.
This section applies to electronic output power (lamp power) is not greater than 150W control device.
This section does not include stand-alone electronic lighting controls, they belong to CISPR15.2005 applicable range.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
CISPR15.2005 A1.2006 A2.2008 Limits and side of radio disturbance characteristics of electrical lighting and similar equipment
Method (Limitsandmethodsofmeasurementofradiodisturbancecharacteristicsofelectricallightingand
similarequipment)
3 to determine compliance
If the electronic control unit together with a reference lamps comply with CISPR15.2005 Table 2a terminal voltage limits and Table 3a, Table 3b or
Table B.1 radiation disturbance limits, then considered to comply with CISPR15.2005 Radio disturbance limits. When the electronic control unit by an external
When the control device, the control terminal disturbance voltage shall comply with CISPR15.2005 limits.
However, it should be noted that the reference was not a lamp fixture reference lamps use the worst case does not accurately reflect the actual lighting
Performance. Built-in test the electronic control unit of the actual lighting, can not be directly considered to meet the CISPR15.2005 requirements.
For EMC compliance, luminaire manufacturers should also consider Chapter 6 and 7 of this section, as well as lighting control manufacturer
Installation instructions.
Test Method 4
Follow the instructions in Chapter 5, the electronic control device is mounted within the reference lamps.
When the electronic control unit is designed to drive more than one lamp, all lamps should work simultaneously.
The connection should be tested at the maximum rated power source.
The reference lamp according to CISPR15.2005 test method for testing as specified.
The test shall use an electronic control device is designed to match the lamp.
CISPR15.2005 working conditions apply.
5 Baseline Lamps
5.1 Structure
Lamps made a reference 1mm ± 0.5mm thick metal plate, Figure A.1 specifications, with output power less than 150W
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 22148.2-2014_English be delivered?Answer: Upon your order, we will start to translate GB/T 22148.2-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 22148.2-2014_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22148.2-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|