HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 19371.2-2007 English PDF

US$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 19371.2-2007: Feed methionine hydroxy analogue HPLC
Status: Valid

GB/T 19371.2: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 19371.2-2007English159 Add to Cart 3 days [Need to translate] Feed methionine hydroxy analogue HPLC Valid GB/T 19371.2-2007
GB/T 19371.2-2003English239 Add to Cart 2 days [Need to translate] Determination of liquid methionine hydroxy analogue in feeds -- High-performance liquid chromatography Obsolete GB/T 19371.2-2003

PDF similar to GB/T 19371.2-2007


Standard similar to GB/T 19371.2-2007

GB/T 18633   GB/T 19541   GB/T 18872   GB/T 17818   GB/T 45200   GB/T 17812   

Basic data

Standard ID GB/T 19371.2-2007 (GB/T19371.2-2007)
Description (Translated English) Feed methionine hydroxy analogue HPLC
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard B46
Classification of International Standard 65.120
Word Count Estimation 6,661
Date of Implementation 2007-09-01
Older Standard (superseded by this standard) GB/T 19371.2-2003
Quoted Standard GB/T 6682; GB/T 14699.1; GB/T 19371.1-2003
Regulation (derived from) China National Standard Announcement 2007 No.7 (Total No.107) - National-Standard-Commission
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard provides high-performance liquid chromatography (HPLC) determination of compound feed and feed concentrates in liquid methionine hydroxy analogue and mixed feed, concentrated feed and feed additive methionine hydroxy method premixed calcium. This standard applies to the determination of compound feed and feed liquid methionine hydroxy analogue concentrated. Also applies to the feed, concentrated feed and feed additives determination of calcium hydroxy methionine premixed.

GB/T 19371.2-2007: Feed methionine hydroxy analogue HPLC

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Feed methionine hydroxy analogue HPLC ICS 65.120 B46 National Standards of People's Republic of China Replacing GB/T 19371.2-2003 Determination of feed methionine hydroxy analogue High Performance Liquid Chromatography Posted 2007-06-21 2007-09-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is GB/T 19371.2-2003 "feeds liquid MHA High performance liquid chromatography" repair Revised edition. This standard and GB/T 19371.2-2003 main differences are as follows. --- To modify the standard name from the "feed liquid MHA determination" to "feed MHA Determination. " --- To modify the measurement range, an increase in the scope of the determination of methionine hydroxy premix of calcium. --- On the result of the calculation modified by the addition of methionine hydroxy formula of calcium. --- The minimum detectable amount of specification limit of quantification. From the date of implementation of this standard instead of GB/T 19371.2-2003. The standard proposed by the People's Republic of China Ministry of Agriculture. This standard by the National Standardization Technical Committee of the feed industry. This standard was drafted. National Feed Quality Supervision and Inspection Center (Beijing). The main drafters of this standard. Yan Hui Wen, Zhao Xiaoyang, Sood Cheng, Huai Yan Ming. This standard replaces the standards previously issued as follows. --- GB/T 19371.2-2003. Determination of feed methionine hydroxy analogue High Performance Liquid Chromatography

1 Scope

This standard specifies a high performance liquid chromatography (HPLC) determination of compound feed and feed concentrates in liquid MHA and complexes Feed, concentrated feed and feed additive method of calcium hydroxy methionine premix. This standard applies to the determination of compound feed and feed liquid MHA concentrates, also applicable to compound feed, concentrated feed And feed additive premix Determination of calcium hydroxy methionine. The standard limit of quantification was 0.03%.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 14699.1 feed samples GB/T 19371.1-2003 feed additive liquid MHA Principle 3 The sample was extracted MHA with 10% acetonitrile in water with potassium hydroxide hydrolysis of the MHA have Reactive monomers, phosphoric acid to adjust the pH of the hydrolyzate. Determination of Methionine Hydroxyl phase high performance liquid chromatography, UV detector at 214nm Analogues content. By the MHA content can be converted from hydroxy methionine content of calcium.

4 Reagents

The following reagents used, unless otherwise stated are gifted class pure reagents, water comply with GB/T 6682 a water use. 4.1 acetonitrile. chromatography. 4.2 Extraction solvent. 10% aqueous acetonitrile. 4.3 Potassium hydroxide solution. 50%. Phosphoric acid 4.4. 1 + 1 (volume ratio). 4.5 HPLC mobile phase. 5% acetonitrile in water, was added 0.5mL of trifluoroacetic acid per liter. 4.6 MHA standard sample. standard purchase unless otherwise basis having GB/T 19371.1-2003 accurate determination.

5 Equipment

5.1 Oscillator. horizontal oscillation frequency 250r/min ~ 300r/min. 5.2 ultrasonic bath. 5.3 HPLC system consisting of the following components. 5.3.1 UV detector, measured at 210nm suitable place. 5.3.2 Analysis Column. packed with a particle size of 5μm C18 bonded silica gel column or equivalent other analytical column. The column temperature was room temperature.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 19371.2-2007_English be delivered?

Answer: Upon your order, we will start to translate GB/T 19371.2-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 19371.2-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 19371.2-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 19371.2-2007?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19371.2-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.