US$199.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19346.1-2017: Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens Status: Valid GB/T 19346.1: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19346.1-2017 | English | 199 |
Add to Cart
|
3 days [Need to translate]
|
Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens
| Valid |
GB/T 19346.1-2017
|
| GB/T 19346-2003 | English | 279 |
Add to Cart
|
3 days [Need to translate]
|
Measuring method of magnetic properties at alternative current for amorphous and nanocrystalline soft magnetic alloys
| Obsolete |
GB/T 19346-2003
|
PDF similar to GB/T 19346.1-2017
Basic data | Standard ID | GB/T 19346.1-2017 (GB/T19346.1-2017) | | Description (Translated English) | Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | H21 | | Classification of International Standard | 77.040.99 | | Word Count Estimation | 10,186 | | Date of Issue | 2017-02-28 | | Date of Implementation | 2017-11-01 | | Older Standard (superseded by this standard) | GB/T 19346-2003 | | Quoted Standard | GB/T 2900.1; GB/T 9637 | | Regulation (derived from) | National Standard Announcement No. 4 of 2017 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the measurement method of AC magnetic properties of amorphous nanocrystalline alloy wound coil specimens. This standard is applicable to measuring the relative amplitude magnetic permeability in the frequency range of 50 Hz to 200 kHz for various transformer and inductance components and the amorphous nanocrystalline soft magnetic alloy for magnetic shielding, than the total loss, the apparent power Such as AC magnetic properties. If there is a suitable calibrated instrument, the upper frequency limit can be extended to 1 MHz, but the reproducibility should be appropriately relaxed. |
GB/T 19346.1-2017: Amorphous and nanocrystalline alloys measurement methods -- Part 1: AC magnetic properties by the use of ring specimens ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Amorphous and nanocrystallometry measurements methods - Part 1. AC magnetic properties by the use of ring specimens
ICS 77.040.99
H21
National Standards of People's Republic of China
Replace GB/T 19346-2003
Test method for amorphous nanocrystalline alloys
Part 1. alternating magnetic properties of annular specimens
Part 1. ACmagneticpropertiesbytheuseofringspecimens
2017-02-28 released
2017-11-01 implementation
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
China National Standardization Management Committee released
Foreword
This part is part 1 of GB/T 19346.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the replacement GB/T 19346-2003 "amorphous nanocrystalline soft magnetic alloy AC magnetic properties test method".
Compared with GB/T 19346-2003, the main contents are as follows.
--- name changed to "amorphous nanocrystalline alloy test method part 1. ring sample AC magnetic performance";
- Added terms and definitions (see Chapter 3);
- removed the voltammetric method of AC magnetic measurement (see Chapter 3 of the.2003 edition);
- Added general rules and modified sample requirements (see Chapter 4, Chapter 4 of the.2003 edition);
- Added technical requirements for digital peak ammeter, voltage digital-to-analog converters and power meters (see 5.4, 5.5, 5.16,.2003)
Chapter 6);
- a method of measuring the permeability and magnetization curves by voltammetry (see Chapter 6);
- Removal of the voltammetric method (see 5.1 of.2003);
- increased method of measuring total loss with a power meter (see Chapter 7);
- modified and supplemented the digital sampling method and increased the measurement method of apparent power (see Chapter 8, Edition 5.2 of.2003);
- Increased requirements for reproducibility and uncertainty assessment of measurement results (see Chapter 9);
- Added the measurement report (see Chapter 10, Chapter 8 of the.2003 edition).
This part is made by China Iron and Steel Industry Association.
This part is headed by the National Steel Standardization Technical Committee (SAC/TC183).
This part of the drafting unit. China Steel Research Technology Group Co., Ltd., Metallurgical Industry Information Standards Institute, China Institute of Metrology.
The main drafters of this part. Lu Zhichao, Chen Wenzhi, Luan Yan, Li Deren, Liu Guodong, Zhang Zhigao, He Jian.
This part of the previous version of the standard to replace the release of the situation.
--- GB/T 19346-2003.
Test method for amorphous nanocrystalline alloys
Part 1. alternating magnetic properties of annular specimens
1 Scope
This part of GB/T 19346 specifies the measurement method for the alternating magnetic properties of amorphous nanocrystalline alloy wound ring specimens.
This part is suitable for measuring a variety of transformer and inductance components and magnetic shielding with amorphous nanocrystalline soft magnetic alloy at 50Hz ~
200kHz frequency range of the relative amplitude of the permeability, than the total loss, compared to the apparent power AC magnetic performance. If there is a suitable calibration
Of the instrument, the frequency upper limit can be extended to 1MHz, but this time the reproduction should be appropriate to relax the requirements.
2 normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article
Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 2900.1 Basic terminology for electrical terminology
Electrotechnical terminology - Magnetic materials and components GB/T
3 terms and definitions
GB/T 2900.1 and GB/T 9637 and the following terms and definitions apply to this document.
3.1
Than the total loss of specifictotalloss
The total power absorbed by the unit mass of the homogeneous magnetized material in watts per kilogram (W/kg).
3.2
More specific than the apparent power
Than apparent power
The total apparent power delivered to the uniform magnetization of the unit mass in volts per kilogram (VA/kg).
4 General rules
4.1 Specimen
4.1.1 Measurement of AC magnetic properties of amorphous nanocrystalline soft magnetic alloys An annular specimen made of strip is used. If no special requirements, winding system
The strip surface does not take insulation measures when the sample is taken.
4.1.2 Recommended specimen diameter of 35mm ± 2mm, the sample diameter and diameter ratio should be less than 1.25. If you need to use other feet
The sample should be stated in the measurement report.
4.1.3 Specimens should be flat, burr, deformation and other defects.
4.1.4 The specimen shall be subjected to appropriate heat treatment prior to measurement. Specimen in the heat treatment process, should use non-ferromagnetic metal or ceramic lining support
Hold the specimen inside the window to prevent the specimen from being deformed. The diameter of the lining should be slightly smaller than the diameter of the specimen and the height is comparable to that of the specimen. Sample heat treatment should be
In a protective atmosphere to prevent surface oxidation.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19346.1-2017_English be delivered?Answer: Upon your order, we will start to translate GB/T 19346.1-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19346.1-2017_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19346.1-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 19346.1-2017?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19346.1-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|