US$229.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 19185-2008: Calculation method of live working minimum approach distance on a.c. transmission line Status: Valid GB/T 19185: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 19185-2008 | English | 229 |
Add to Cart
|
3 days [Need to translate]
|
Calculation method of live working minimum approach distance on a.c. transmission line
| Valid |
GB/T 19185-2008
|
| GB/T 19185-2003 | English | 319 |
Add to Cart
|
3 days [Need to translate]
|
AC live line safety distance calculation method
| Obsolete |
GB/T 19185-2003
|
PDF similar to GB/T 19185-2008
Basic data | Standard ID | GB/T 19185-2008 (GB/T19185-2008) | | Description (Translated English) | Calculation method of live working minimum approach distance on a.c. transmission line | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | K47 | | Classification of International Standard | 29.240.20 | | Word Count Estimation | 10,173 | | Date of Issue | 2008-09-24 | | Date of Implementation | 2009-08-01 | | Older Standard (superseded by this standard) | GB/T 19185-2003 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 16 of 2008 (No. 129 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the exchange of live line work safety clearance distance and combined method of calculating risk assessment criteria, the gap coefficient, altitude correction coefficient. The calculated results and experimental studies for design reference. This standard applies to 110kV ~ 750kV AC line safe distance and composition of live working gap is calculated and checked. Live working in substation equipment a safe distance and composition of the gap calculation check, or you can refer to adopt. |
GB/T 19185-2008: Calculation method of live working minimum approach distance on a.c. transmission line ---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calculation method of live working minimum approach distance on actransmission line
ICS 29.240.20
K47
National Standards of People's Republic of China
Replacing GB/T 19185-2003
AC Live Line Work Safety Distance Calculation
Posted 2008-09-24
2009-08-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 lines operating over-voltage 2
5 3 Calculation Method
6 calculated coefficients and values \u200b\u200b3
7 hazard rate calculation 4
Environmental impact of 8 5
9 Calculation Example 5
Foreword
This standard replaces GB/T 19185-2003 "AC Live Line Work Safety Distance Calculation Method."
The main difference compared with the standard GB/T 19185-2003 as follows.
--- On the "Terms and Definitions" chapter "occupying an intermediate potential conductor length", "a combination of a minimum clearance", "statistical safety factor", "middle
Conductor potential influence coefficients "and other terms were added;
--- In the "Calculation Method" chapter complements the "minimum clearance combination" is calculated;
--- In the "coefficient calculation and values" chapter complements the "occupying intermediate potential conductor length", "middle conductor potential impact factor" of
Value method;
--- On the "Calculation examples" chapter "Table 3 security clearance from the combination calculated value" added "a combination of minimum clearance" list.
The standard proposed by China Electricity Council.
This standard by the National Standardization Technical Committee work and live under the jurisdiction responsible for the interpretation.
This standard was drafted. State Grid Wuhan High Voltage Research Institute, Henan Province Pingdingshan Electric Power Bureau.
The main drafters of this standard. Hu Yi, Zhao Jiang, Wu Weining, Yi Hui, Zhang Lihua, Hujian Xun, Shu, the peak.
This standard replaces the standards previously issued as follows.
--- GB/T 19185-2003.
AC Live Line Work Safety Distance Calculation
1 Scope
This standard specifies the calculation method of the exchange of live line work and combination safe distance gap, risk assessment criterion, the gap coefficient, sea
Stubbs correction coefficient. The result of the calculation for the design and testing research reference.
This standard applies to 110kV ~ 750kV AC live line work safe distance and gap combination calculating and checking. In the substation located
Combination safe distance and prepare for live working gap calculation check, but also can refer to use.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 18037 live working tools Technical requirements and design guide
Overvoltage protection and insulation coordination DL/T 620 AC electrical installations
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
RMS maximum operating voltage under normal operating conditions, the system appears (phase - phase).
3.2
2% probability of occurrence of overvoltage.
3.3
Insulation presents a 50% probability of flashover impulse voltage peaks.
3.4
Insulating render 90% probability withstand impulse voltage peaks.
3.5
To ensure that the job presents minimal clearance gap 90% probability impulse withstand distance.
3.6
The projected length of the body is part of the job gap on the gap axis.
3.7
Clearance operation minimum allowed value of the distance from the minimum safe distance from electrical body composition range of activities.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 19185-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 19185-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 19185-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19185-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 19185-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19185-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|