HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (18 Oct 2025)

GB/T 17737.325-2018 English PDF

US$119.00 ยท In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 17737.325-2018: Coaxial communication cables -- Part 1-325: Mechanical test methods -- Aeolian vibration
Status: Valid
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 17737.325-2018English119 Add to Cart 2 days [Need to translate] Coaxial communication cables -- Part 1-325: Mechanical test methods -- Aeolian vibration Valid GB/T 17737.325-2018

PDF similar to GB/T 17737.325-2018


Standard similar to GB/T 17737.325-2018

GB/T 17737.102   GB/T 17737.101   GB/T 17737.103   GB/T 17737.318   GB/T 17737.324   GB/T 17737.317   

Basic data

Standard ID GB/T 17737.325-2018 (GB/T17737.325-2018)
Description (Translated English) Coaxial communication cables -- Part 1-325: Mechanical test methods -- Aeolian vibration
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard L26
Classification of International Standard 33.120.10
Word Count Estimation 6,620
Date of Issue 2018-03-15
Date of Implementation 2018-10-01
Issuing agency(ies) State Administration for Market Regulation, China National Standardization Administration

GB/T 17737.325-2018: Coaxial communication cables -- Part 1-325: Mechanical test methods -- Aeolian vibration


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Coaxial communication cables--Part 1-325. Mechanical test methods--Aeolian vibration ICS 33.120.10 L26 National Standards of People's Republic of China Coaxial communication cable Part 1-325. Mechanical Test Methods Wind-induced vibration test Part 1-325. Mechanical test methods- (IEC 61196-1-325.2008, IDT) Published by.2018-03-15 2018-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration released

Foreword

GB/T 17737 "Coaxial Communication Cable" has or plans to issue the following parts. --- Part 1. General rules, definitions and requirements; --- Section 1-31 . Mechanical test methods ; Ellipticity test ; -- Part 1-302 . Mechanical test methods ; eccentricity test ; -- Part 1-304 . Mechanical test methods ; Impact test ; Part 1-108 . Mechanical test methods -- Tensile strength and elongation test of copper clad metal ; --- Part 1-310. Mechanical test methods Torsional characteristics of copper clad metal; --- Part 1-313. Mechanical test methods Adhesion of media and sheath; --- Part 1-314. Mechanical test methods Bending test of cables; --- Part 1-316. Mechanical test methods Maximum tensile strength test of cables; --- Part 1-317. Mechanical test methods Cable compression test; --- Sections 1-318. Mechanical test methods Thermal performance test; --- Part 1-324 . Mechanical test methods Cable abrasion resistance test ; --- Part 1-325 . Mechanical test methods Wind - induced vibration test ; This section is part 1-325 of GB/T 17737. This section was drafted in accordance with the rules given in GB/T 1.1-2009. This section uses the translation method equivalent to the use of IEC 61196-1-325.2008 "coaxial communication cable Part 1-325. mechanical test side Wind-induced vibration test. The Chinese documents that have a consistent correspondence with the normatively quoted international documents in this section are as follows. ---GB/T 17737.1-2013 Coaxial telecommunication cables Part 1. General specifications General, definitions and requirements (IEC 61196-1. 2005, IDT). Please note that some of the contents of this document may involve patents. The issuing agency of this document does not assume responsibility for identifying these patents. This section was proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part is under the jurisdiction of the National Standardization Technical Committee for High Frequency Cables and Connectors for Electronic Equipment (SAC/TC190). This section was drafted by the 23rd Institute of China Electronics Technology Corporation. The main drafters of this section. Zhu Ping, Zhou Jiyu, Zhai Zehui, Fang Xu, and Tian Xin. Coaxial communication cable Part 1-325. Mechanical Test Methods Wind-induced vibration test

1 Scope

This part of GB/T 17737 applies to coaxial communication cables. It specifies the determination of overhead cables for analog or digital communication systems Test methods for dynamic stresses due to the flow of light wind in overhead lines.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document. IEC 61196-1 Coaxial Communication Cables Part 1. Generic Specification General, Definitions and Requirements (Coaxialcommunicationca- bles-Part 1.Generic specification-General,definitionsandrequirements)

3 Terms and definitions

The terms and definitions defined by IEC 61196-1 apply to this document.

4 test methods

4.1 Samples Unless otherwise specified in the relevant specification, the length of the specimen shall be at least 50 m. Both ends of the specimen should be prepared so as to be within the specified frequency range Attenuation tests can be performed continuously. 4.2 Device The device should include. --- Test device (typical test configuration shown in Figure 1); --- Electronically controlled vibrators; --- dynamometers, load cells, calibrated measuring rods or other devices for measuring cable tension; --- Network analyzer covering the test frequency range; --- Continuity measuring instruments. 4.3 Procedures Both ends of the cable should be terminated. Apply a certain tension to the cable so that the cable is properly installed. Use a dynamometer, load cell, calibrated load cell, or other device that measures cable pull to measure cable tension. Experimental procedure It is advisable for China to take certain measures to keep the tension constant when the temperature fluctuates. Unless otherwise specified in certain specific conditions of use, the cable shall be gradually loaded to the maximum tensile load specified by the relevant specification.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 17737.325-2018_English be delivered?

Answer: Upon your order, we will start to translate GB/T 17737.325-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 17737.325-2018_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 17737.325-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.