GB/T 17289-2009: Liquid hydrocarbons -- Volumetric measurement by turbine meter systems
Status: Valid

GB/T 17289: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 17289-2009English334 Add to Cart 3 days [Need to translate] Liquid hydrocarbons -- Volumetric measurement by turbine meter systems Valid GB/T 17289-2009
GB/T 17289-1998English839 Add to Cart 4 days [Need to translate] Liquid hydrocarbons--Volumetric measurement by turbine meter system Obsolete GB/T 17289-1998

PDF similar to GB/T 17289-2009


Standard similar to GB/T 17289-2009

GB/T 18604   GB/T 23258   GB/T 21447   GB/T 17286.2   GB/T 17286.1   GB/T 17286.3   

Basic data

Standard ID GB/T 17289-2009 (GB/T17289-2009)
Description (Translated English) Liquid hydrocarbons -- Volumetric measurement by turbine meter systems
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard E98
Classification of International Standard 75.180.30
Word Count Estimation 17,125
Date of Issue 2009-03-16
Date of Implementation 2009-10-01
Older Standard (superseded by this standard) GB/T 17289-1998
Quoted Standard GB/T 17287-1998; GB/T 17746-1999
Adopted Standard ISO 2715-1981, IDT
Regulation (derived from) National Standard Approval Announcement 2009 No.2 (Total No.142)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the choice of turbine meter systems, installation, operation and maintenance of general rules. This standard applies to the petroleum industry, in different contexts, using a variety of turbine flow meters for different types of flow measurement of liquid hydrocarbons. This standard does not apply to the measurement of two-phase flow.

GB/T 17289-2009: Liquid hydrocarbons -- Volumetric measurement by turbine meter systems

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Liquid hydrocarbons. Volumetric measurement by turbine meter systems ICS 75.180.30 E98 National Standards of People's Republic of China GB/T 17289-2009/ISO 2715. 1981 Replacing GB/T 17289-1998 Liquid hydrocarbon volume measurement by turbine meter systems (ISO 2715. 1981, IDT) Posted 2009-03-16 2009-10-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

This standard is equivalent to using ISO 2715. 1981 "liquid hydrocarbon volumetric turbine meter systems." This standard is equivalent translation ISO 2715. 1981. This standard of ISO 2715. 1981 made the following editorial changes. --- Remove the ISO international standards foreword; --- The "this International Standard" be replaced by "of this standard." This standard replacement GB/T 17289-1998 "liquid hydrocarbon volumetric turbine meter systems." This standard 17289-1998 major changes compared to GB/T as follows. --- The full text of the ISO 6551. 1982 to GB/T 17746-1999; --- The full text of the GB/T 17288-1998 amended as GB/T 17287-1998; --- Introduction delete the discussion of positive displacement flowmeter. Appendix A of this standard is a normative appendix, Appendix B is an informative annex. The standard proposed by China National Petroleum Corporation. This standard by the National Standardization Technical Committee of Oil and Gas. This standard is drafted by. China National Petroleum Corp. Metrology Institute. The main drafters of this standard. An Shumin, Jiao Xuefeng, Liu Xianying, Zhao Chenghai, Li Peng. The standard standard replaces the previous editions. GB/T 17289-1998. GB/T 17289-2009/ISO 2715. 1981

Introduction

Turbine Flowmeter mainly by detecting passage of the fluid average velocity of the rotor constituted. The kinetic energy of the impact surface of the fluid with a radial guide Rotor angle side ribs and partially decomposed into a tangential kinetic energy of the rotor is rotated, the rotation of the rotor is proportional to the flow rate. By mechanical rotation of the rotor, ,, Magnetic or electronic means of optical detection, and recorded in the readout meter. This test must be recorded with a known volume Volume for comparison. To guide the design of turbine flowmeter liquid hydrocarbons metering devices, installation, operation and maintenance, development of this standard. Appendix A gives the turbine flow Detailing and characteristics of meter components. Appendix B provides troubleshooting guide. GB/T 17289-2009/ISO 2715. 1981 Liquid hydrocarbon volume measurement by turbine meter systems

1 Scope

This standard is based on the nature and characteristics of the measured liquid turbine flowmeter, turbine flowmeter selection provides system design, installation, operation Maintenance and general rules. This standard applies to the petroleum industry, in different contexts, using a variety of turbine flow meters for different types of liquid hydrocarbon flow measurement. This standard does not apply to the measurement of two-phase fluid.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 17287-1998 statistical control of dynamic measurement of liquid hydrocarbon volumetric metering systems (idtISO 4124.1994) GB/T 17746-1999 Petroleum liquids and gases dynamic measuring electric and (or) electronic pulsed data transmission reliability and security cable Truth degree (idtISO 6551. 1982) Select 3 metering system design, flow meters and auxiliary equipment 3.1 Metering System Design Principles 3.1.1 The metering system should be suitable for flow, pressure, temperature changes and the type of fluid to be measured. If desired, the protective equipment should be installed to ensure that Metering system to work at design conditions. 3.1.2 If the metering systems installed in hazardous areas shall comply with national or local regulations on the safe use of electrical equipment requirements. 3.1.3 Materials All parts in contact with liquid hydrocarbons, it can not influence the nature of the media, but also from the impact of media. 3.1.4 with measures to ensure the full scale test flow meter in close working conditions. Select 3.2 turbine flowmeter and auxiliary equipment 3.2.1 Select turbine flowmeter and auxiliary equipment, the manufacturer shall inform the consultation and consider the following. a) mounting space measurement system and the corresponding test equipment; b) meter connection type and pressure rating; c) the measured fluid characteristics, including viscosity, density, vapor pressure, corrosion resistance and lubricity and the like; d) measured liquid impurities entrained wear or corrosion of the nature and quantity, including the size and distribution of solid impurities; e) flow characteristics, including work flow, maximum flow, minimum flow, liquidity and volatility of continuity; f) working pressure range. Run at maximum flow rate through the flow meter and the pressure loss of the auxiliary equipment; g) operating temperature range and automatic temperature compensation adaptability; h) maintenance methods, costs and spare parts required; i) verification of the approach, methods and period; j) the flowmeter characteristics including linearity, the maximum allowable pressure loss, frequency and voltage output (see Figure A.2); k) indicator and the type of signal preamplifier (see Figure A.3); l) and the meter displays the compatibility between the meter readings adjustment method; m) display instrument power supply requirements; n) requirements for electrical specifications; o) the reliability of the electron transport system. GB/T 17289-2009/ISO 2715. 1981