|
US$1119.00 · In stock Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 16608.54-2012: Electromechanical all-or-nothing relays -- Part 54: Blank detail specification -- Electromechanical all-or-nothing telecom relays of assessed quality -- Two change-over contacts, 15mm×7.5mm base Status: Obsolete
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 16608.54-2012 | English | 1119 |
Add to Cart
|
5 days [Need to translate]
|
Electromechanical all-or-nothing relays -- Part 54: Blank detail specification -- Electromechanical all-or-nothing telecom relays of assessed quality -- Two change-over contacts, 15mm×7.5mm base
| Obsolete |
GB/T 16608.54-2012
|
PDF similar to GB/T 16608.54-2012
Basic data | Standard ID | GB/T 16608.54-2012 (GB/T16608.54-2012) | | Description (Translated English) | Electromechanical all-or-nothing relays -- Part 54: Blank detail specification -- Electromechanical all-or-nothing telecom relays of assessed quality -- Two change-over contacts, 15mm��7.5mm base | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | L25 | | Classification of International Standard | 29.120.70 | | Word Count Estimation | 28,225 | | Quoted Standard | GB/T 2421-1999; GB/T 5169.5-1997; GB/T 14598.4-1993; GB/T 16608.1-2003; GB/T 16608.50-2012; IEC 60068-2-17-1994; IEC 600068-2-20-1979; IEC 60068-2-47-1999; IEC 61709-1996; IEC 61810-7-1997; QC 001002-2-1998; QC 001002-3-1998; QC 001005-2000; CECC 00802-19 | | Adopted Standard | IEC 61811-54-2002, IDT | | Regulation (derived from) | National Standards Bulletin No. 28 of 2012 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard is applicable to telecommunications with assessed quality, with or without electromechanical relays. Comply with the provisions of this part of the relay for use in telecommunications equipment, but as with or without electromechanical relay |
GB/T 16608.54-2012: Electromechanical all-or-nothing relays -- Part 54: Blank detail specification -- Electromechanical all-or-nothing telecom relays of assessed quality -- Two change-over contacts, 15mm×7.5mm base
---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Electromechanical all-or-nothing relays Part 54.. Blank detail specification Electromechanical all-or-nothing telecom relays of assessed quality Two change-over contacts, 15mm × 7.5mm base
ICS 29.120.70
L25
National Standards of People's Republic of China
With or without electromechanical relays
Part 54. Blank detail specification
Telecom with assessed quality, with or without electromechanical relays
Two changeover contacts, 15mm × 7.5mm base
Electromechanicalal-or-nothingrelays-Part 54. Blankdetailspecification-
Twochange-overcontacts, 15mm × 7.5mmbase
(IEC 61811-54.2002, IDT)
Issued on. 2013-02-15 2012-11-05 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Introduction Ⅲ
1 General 1
1.1 Scope 1
1.2 Normative references 1
1.3 Detailed specifications page 2
2 4 Relay characteristic value
2.1 General Parameter 4
2.2 IEC model specifications composition (sequence information) 5
2.3 Coil 5
2.4 contact parameters 5
2.4.1 electrical durability and cycle frequency 5
2.4.2 Static resistance contact circuit 6
2.4.3 mechanical durability 6
2.4.4 Time (no suppression devices) 6
2.5 Installation 6
2.6 environmental parameters 6
2.7 automatic operation relay package (when applicable) 7
3 Qualification approval procedures 7
4 Quality conformance inspection 7
7.4.1 Inspection Lot 7
4.2 Periodic Inspection 7
5 Signs and file 7
5.1 relay flag 8
5.2 Package Marking 8
5.3 File 8
6 Appendix 8
7 Test 8
Standard Test Conditions 7.1 8
During the installation of the test sample 7.2 Test 8
General Conditions 7.3 Test 8
8 8 sequence information
9 --- relay reliability failure rate data (optional) 9
Foreword
GB/T 16608 "have no basis or electromechanical relays" standard is currently divided into the following sections.
--- GB/T 16608.1 assessed quality, with or without foundation electromechanical relays - Part 1. Generic specification;
--- GB/T 16608.50 with or without electromechanical relays - Part 50. Sectional specification telecommunications with assessed quality, with or without electromechanical
Relay;
--- GB/T 16608.51 with or without electromechanical relays - Part 51. Blank detail specification telecommunications with assessed quality, with or
No non-standard electromechanical relays type and structure;
--- GB/T 16608.52 with or without electromechanical relays - Part 52. Blank detail specification telecommunications with assessed quality, with or
Nothing relays two changeover contacts, 20mm × 10mm base;
--- GB/T 16608.53 with or without electromechanical relays - Part 53. Blank detail specification telecommunications with assessed quality, with or
Nothing relays two changeover contacts, 14mm × 9mm base;
--- GB/T 16608.54 with or without electromechanical relays - Part 54. Blank detail specification telecommunications with assessed quality, with or
Nothing relays two changeover contacts, 15mm × 7.5mm base;
--- GB/T 16608.55 with or without electromechanical relays - Part 55. Blank detail specification telecommunications with assessed quality, with or
Nothing relays two changeover contacts, 11mm × 7.5mm (maximum) base.
This section GB/T 16608 Part 54.
This section Press GB/T 1.1-2009 given rule drafting.
This section uses the translation method identical with IEC 61811-53.2002 "with or without electromechanical relays - Part 54. Blank detail specification
Telecom with assessed quality, with or without electromechanical relays two changeover contacts, 15mm × 7.5mm base. "
For ease of use, this section made the following editorial changes.
--- With "this Part" instead of "this International Standard";
--- With a decimal symbol instead of the symbol ",". ",";
--- Remove the IEC standard foreword;
--- The Table 2 3 contact circuit by a unit of resistance "Ω" converted to "mΩ".
This part is proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
This part of the National Electrical relays with or without Standardization Technical Committee (SAC/TC217) centralized.
This section is drafted. Xiamen Hongfa Electroacoustic Co., Ltd.
The main drafters of this section. Desheng, Wang Jue, Shi Xinyuan, Wang Junqing, Luning Yi.
With or without electromechanical relays
Part 54. Blank detail specification
Telecom with assessed quality, with or without electromechanical relays
Two changeover contacts, 15mm × 7.5mm base
1 General
1.1 Scope
GB/T 16608 in this section is blank detail specification for telecommunications with assessed quality, with or without electromechanical relays. Comply with this
Relay portion provided for use in telecommunications equipment, but as with or without electromechanical relays, also can be used in a particular industry or other
equipment.
Test methods specified in this section is taken from IEC 61810-7.1997 and other standards, according to detailed specifications for the development of this specification adoption.
This section also provides a basic test table for detailed specification according to GB/T 16608.1-2003 provisions established use.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2421-1999 Environmental testing for electric and electronic products - Part 1. General (IEC 60068-1. 1988, IDT)
GB/T 5169.5-1997 Fire hazard testing for electric and electronic products - Part 2. Test methods - Section 2. Needle-flame test
(IEC 60695-2-2.1991, IDT)
GB/T 14598.4-1993 Electrical relays - Part 14. Endurance test for electrical relay contacts Contact load priority
Value (IEC 60255-14. 1981, IDT)
GB/T 16608.1-2003 assessed quality, with or without foundation electromechanical relays - Part 1. Generic specification (IEC 61811-1.
1999, IDT)
GB/T 16608.50-2012 with or without electromechanical relays - Part 50. Sectional specification telecommunications with assessed quality, with or inorganic
Electrical relay (IEC 61811-50.2002, IDT)
IEC 60068-2-17.1994 Environmental testing - Part 2. Tests - Test Q. Sealing (Environmentaltesting-Part
2. Tests-TestQ. Sealing)
IEC 60068-2-20. 1979 Environmental testing - Part 2. Tests - Test T. Soldering tests (including amendments 2. 1987) (Envi-
ronmentaltesting-Part 2. Tests-TestT. Soldering) Amendment2 (1987)
IEC 60068-2-47.1999 Environmental testing - Part 2-47. Test methods for vibration, impact and similar dynamic tests components,
Equipment installation and other objects (Environmentaltesting-Part 2-47. Test methods-Mountingofcomponents,
equipmentandotherarticlesforvibration, impactandsimilardynamictests)
IEC 61709.1996 Electronic Component reliability failure rate of standard conditions and stress model conversion (Electroniccom-
ponents-Reliability-Referenceconditionsforfailureratesandstressmodelsforconversion)
IEC 61810-7.1997 with or without electromechanical relays - Part 7. Test and measurement procedures (Electromechanicalal-or-
nothingrelays-Part 7. Testandmeasurementprocedures)
QC001002-2.1998 IEC Quality Assessment System for Electronic Components procedural rules (IEC Q) - Part 2. File (Rulesof
ProcedurefortheIEC QualityAssessmentSystemforElectronicComponents (IEC Q) -Part 2. Docu-
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 16608.54-2012_English be delivered?Answer: Upon your order, we will start to translate GB/T 16608.54-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 16608.54-2012_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 16608.54-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.
|