HOME   Cart(0)   Quotation   About-Us Tax PDFs Standard-List Powered by Google www.ChineseStandard.net Database: 189759 (12 Jan 2025)

GB/T 17737.100-2018 PDF English


Search result: GB/T 17737.100-2018_English: PDF (GB/T17737.100-2018)
Standard IDContents [version]USDSTEP2[PDF] delivered inName of Chinese StandardStatus
GB/T 17737.100-2018English90 Add to Cart 0-9 seconds. Auto-delivery. Coaxial communication cables -- Part 1-100: Electrical test methods -- General requirements Valid
BUY with any currencies (Euro, JPY, GBP, KRW etc.): GB/T 17737.100-2018     Related standards: GB/T 17737.100-2018

PDF Preview: GB/T 17737.100-2018


GB/T 17737.100-2018: PDF in English (GBT 17737.100-2018)

GB/T 17737.100-2018 Coaxial communication cables--Part 1-100. Electrical test methods--General requirements ICS 33.120.10 L26 National Standards of People's Republic of China Coaxial communication cable Part 1-100. Electrical test methods common enquiries Part 1-100. Electricaltestmethods-Generalrequirements (IEC 61196-1-100.2015, IDT) Published on.2018-03-15 2018-10-01 implementation General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration issued Foreword GB/T 17737 "Coax Cable" has been or is planned to release the following parts. --- Part 1. General rules, definitions and requirements; ---Part 1-100. General requirements for electrical test methods; --- Part 1-101. Electrical test method Conductor DC resistance test; --- Part 1-102. Electrical test method cable dielectric insulation resistance test; --- Part 1-1-3. Electrical test method for cable capacitance test; --- Part 1-1-4. Electrical test method for the capacitance stability test of cables; --- Part 1-105. Electrical test method for withstand voltage test of cable media; ---Parts 1-106. Electrical test method - Withstand voltage test for cable sheathing; --- Part 1-107. Electrical test method cable trembling charge level (mechanical induction noise) test; --- Part 1-108. Electrical test methods for characteristic impedance, phase delay, group delay, electrical length and propagation speed test; --- Part 1-110. Electrical test method continuity; --- Part 1-111. Stability test of phase constants of electrical test methods; --- Part 1-112. Electrical test method return loss (impedance consistency) test; --- Part 1-113. Electrical test method attenuation constant test; --- Part 1-114. Electrical test method inductance; --- Part 1-115. Electrical test method impedance uniformity (pulse/step function return loss) test; --- Part 1-161. Electrical test method TDR method to measure characteristic impedance; --- Part 1-119. Electrical test methods - RF rated power; --- Part 1-122. Electrical test method Crosstalk test between coaxial cables; This part is part 1-100 of GB/T 17737. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part uses the translation method equivalent to IEC 61196-1-100.2015 "Coaxial Communication Cables Part 1-100. Electrical Test Side General Requirements for Law. The documents of our country that have a consistent correspondence with the international documents referenced in this part are as follows. Coaxial communication cables - Part 1 . General rules, definitions and requirements (IEC 61196-1. 2005, IDT) Please note that some of the contents of this document may involve patents. The issuing organization of this document is not responsible for identifying these patents. This part was proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This part is under the jurisdiction of the National High-Tech Cable and Connector Standardization Technical Committee for Electronic Equipment (SAC/TC190). This section was drafted. The 23rd Research Institute of China Electronics Technology Group Corporation. The main drafters of this section. Fang Xu, Yin Haicheng, Tian Xin. Coaxial communication cable Part 1-100. Electrical test methods common enquiries 1 Scope This part of GB/T 17737 gives the general requirements and conditions for the electrical test of coaxial communication cables. This section applies to GB/T 17737.1×× series standard, which specifies the electrical test method for coaxial communication cables. Test details (eg temperature, duration) and/or test requirements will be given in the relevant cable standards. 2 Normative references The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. Coaxial communication cables - Part 1. General specification, definitions and requirements (Coaxialcommunication cables-Part 1. Genericspecification-General, definitionsandrequirements) 3 Terms and definitions The terms and definitions defined in IEC 61196-1 apply to this document. 4 sample 4.1 Test Cable (CUT) Unless otherwise specified in the relevant test methods, the length of the cable to be tested (CUT) should be selected taking into account the dynamic range of the measuring equipment and the specified frequency. Rate range to get the required measurement accuracy. Cable length measurement accuracy should be better than 1% unless otherwise specified in the relevant cable specification. 4.2 Pretreatment The cable under test shall be pretreated at a constant ambient temperature for a certain period of time to stabilize the temperature of the sample within the temperature range specified in 6.1. 5 test The test and performance characteristics required for cables of different sizes are specified by the relevant cable standards. 6 Test conditions 6.1 Environmental conditions Unless otherwise specified, the test shall be carried out in the following environments. --- Temperature. 15 ° C ~ 35 ° C; ---Relative humidity. 25%~75% (no condensation phenomenon); --- Air pressure. 86kPa ~ 106kPa. 6.2 Temperature tolerance Unless otherwise specified in the relevant specifications, the temperature tolerance shall be ±2 °C. 6.3 Stability of frequency range and frequency dependent measurements The required frequency range is specified by the relevant sub-specification. The sweep should be linear or logarithmic. The linear sweep is performed according to equation (1); the log sweep is performed according to equation (2), namely. Fstep= Fstop-fstart N-1 (1) K= Fstop Fstart{ } N-1 (2) In the formula. Fstep---linear frequency increment, constant over the entire specified frequency range; Fstop---the specified maximum frequency; Fstart---the minimum frequency specified; n --- frequency points; K --- logarithmic frequency increment. Unless otherwise specified, the minimum number of frequency points per decade may be.200. 7 test report The test report shall include the measurement results and their maximum error, actual measurement conditions and their maximum error. Appendix A (informative appendix) IEC 61196-1-1×× series electrical test method IEC 61196-1-1×× consists of the following standards. IEC 61196-1-100 (general requirements) IEC 61196-1-101 (conductor DC resistance test) IEC 61196-1-102 (Cable dielectric insulation resistance test) IEC 61196-1-103 (capacitance test of cables) IEC 61196-1-104 (Stability test of cable capacitance with temperature) IEC 61196-1-105 (withstand voltage test of cable media) IEC 61196-1-106 (withstand voltage test of cable sheath) IEC 61196-1-107 [Cable Diffraction Charge Level (Mechanical Induction Noise) Test] IEC 61196-1-108 (characteristic impedance, phase delay, group delay, electrical length and propagation speed test) IEC 61196-1-110 (continuity) IEC 61196-1-111 (Phase stability test method) IEC 61196-1-112 [Return loss (impedance consistency) test] IEC 61196-1-113 (Attenuation Constant Test) IEC 61196-1-114 (inductance) IEC 61196-1-115 [Impedance uniformity (pulse/step function return loss) test] IEC 61196-1-116 (TDR method for measuring characteristic impedance) IEC 61196-1-119 (RF rated power) IEC 61196-1-122 (coaxial cable crosstalk test) ......
 
Source: Above contents are excerpted from the PDF -- translated/reviewed by: www.chinesestandard.net / Wayne Zheng et al.