US$189.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 15609-2008: Measurement methods for the chromaticity of color displays Status: Valid GB/T 15609: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 15609-2008 | English | 189 |
Add to Cart
|
3 days [Need to translate]
|
Measurement methods for the chromaticity of color displays
| Valid |
GB/T 15609-2008
|
| GB/T 15609-1995 | English | 199 |
Add to Cart
|
2 days [Need to translate]
|
Methods of measuring the chromaticity of colour television
| Obsolete |
GB/T 15609-1995
|
PDF similar to GB/T 15609-2008
Basic data | Standard ID | GB/T 15609-2008 (GB/T15609-2008) | | Description (Translated English) | Measurement methods for the chromaticity of color displays | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | M74 | | Classification of International Standard | 33.160.25 | | Word Count Estimation | 8,897 | | Date of Issue | 2008-05-26 | | Date of Implementation | 2008-11-01 | | Older Standard (superseded by this standard) | GB/T 15609-1995 | | Quoted Standard | GB/T 5698-2001; GB/T 17309.1-1998; SJ/T 11348-2005; IEC 60107-1997 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 9, 2008 (No. 122 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the color monitor color test conditions, measurement methods classification, spectrophotometric color measurement method, tristimulus Direct Reading, display color measurement, the measurement results presentation. This standard applies to color displays chromaticity measurements. |
GB/T 15609-2008: Measurement methods for the chromaticity of color displays---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Measurement methods for the chromaticity of color displays
ICS 33.160.25
M74
National Standards of People's Republic of China
Replacing GB/T 15609-1995
Color display color measurement methods
Posted 2008-05-26
2008-11-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard replaces GB/T 15609-1995 "color television color measurement method."
This standard and GB/T 15609-1995 compared to the main changes are as follows.
--- For the name of GB/T 15609-1995 standard was changed;
--- Increase the spectral radiometer and the photoelectric colorimeter technical requirements of the regulations;
--- Increase the measurement display color and viewing angle relationship;
--- Increase in the optical axis perpendicular to the center of the display screen, the display of the measurement and reference white balance requirements;
--- Increase the measurement of the color gamut coverage.
The standard color by the National Standardization Technical Committee.
This standard color by the National Standardization Technical Committee.
This standard was drafted. Shenzhen Ocean Power Industrial Co., Ltd., Shenzhen Haichuan Color Technology Co., Ltd.
The main drafters of this standard. He Weiping, Huang Yongheng, Tang Hui Gong, high sword, Nimeng Lin.
This standard replaces the standards previously issued as follows.
--- GB/T 15609-1995.
Color display color measurement methods
1 Scope
This standard specifies the color display color test conditions, measurement classification, spectrophotometric color measurement method, tristimulus value direct reading method, display
Measuring color measurement results Fig.
This standard applies to the measurement of the color display color.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 5698-2001 term color
GB/T 17309.1-1998 television broadcast receiver measuring methods - Part 1. General considerations electrical measurements at radio and video frequencies
And display performance measurements (IEC 60107-1.1995, IDT)
SJ/T 11348-2006 Methods of measurement of digital TV flat panel display
IEC 60107-1.1997 Measurement method of transmitting television broadcast receivers - Part 1. General requirements for radio and television frequencies was
Measurement shown
3 Terms and Definitions
The standard terms and definitions should be consistent with GB/T 5698-2001 requirements.
4 Test Conditions
4.1 standard light source, the light source and the display to be measured with a calibration should be preheated to light stability.
4.2 should be under the same geometrical conditions on the standard light source, the light source and the display to be measured with a calibration test.
4.3 Test Site should not affect the test results of the ambient light, stray light is less than or equal to 1lx. Measure the luminance, chrominance, should be
Darkroom.
4.4 Test Site should not significantly affect the results of the external electric and magnetic fields.
4.5 Main test instruments must be regularly calibrated.
Measurement Category 5
5.1 In general, you should use tristimulus value direct reading method.
5.2 pairs of test accuracy requirements of high, or as a reference standard transmission, you should use spectrophotometric color measurement method.
6 spectrophotometric color measurement method
6.1 spectroradiometer requirements
6.1.1 Wavelength range. 380nm ~ 780nm, generally not less than 400nm ~ 700nm.
6.1.2 Wavelength Accuracy. Error ≤0.5nm.
6.1.3 interval and the pass bandwidth of the wavelength. for the reference measurement < 2nm, for general measurement < 5nm.
6.1.4 When measuring LCD monitor, PDP display, when the DLP monitor, select spectral radiometer with a telephoto lens.
6.1.5 Metering repeatability should be within 1%.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15609-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 15609-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15609-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15609-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15609-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15609-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|