GB/T 15510-2008: General rules for reliability test of electromagnetic relay for control circuits
Status: Valid

GB/T 15510: Evolution and historical versions

Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 15510-2008English329 Add to Cart 3 days [Need to translate] General rules for reliability test of electromagnetic relay for control circuits Valid GB/T 15510-2008
GB/T 15510-1995English519 Add to Cart 4 days [Need to translate] General rules for reliability test of electromagnetic relay for control circuits Obsolete GB/T 15510-1995

PDF similar to GB/T 15510-2008


Standard similar to GB/T 15510-2008

DL/T 540   GB/T 38953   GB/T 37155.2   GB/T 45648.1   GB/T 45568   GB/T 45648.2   

Basic data

Standard ID GB/T 15510-2008 (GB/T15510-2008)
Description (Translated English) General rules for reliability test of electromagnetic relay for control circuits
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard K45
Classification of International Standard 29.120.50
Word Count Estimation 14,197
Date of Issue 2008-06-18
Date of Implementation 2009-03-01
Older Standard (superseded by this standard) GB/T 15510-1995
Quoted Standard GB/T 2423 (series); GB/T 14598.5-1993
Regulation (derived from) Announcement of Newly Approved National Standards No. 10 of 2008 (total 123)
Issuing agency(ies) General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary This standard specifies the control electromagnetic relay reliability test volume terms and their definitions and symbols, reliability index, test methods, classification and test reliability verification test procedures, test records and test reports. This standard applies to the product life can be reasonably considered to be exponentially distributed product reliability verification test.

GB/T 15510-2008: General rules for reliability test of electromagnetic relay for control circuits

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
General rules for reliability test of electromagnetic relay for control circuits ICS 29.120.50 K45 National Standards of People's Republic of China Replacing GB/T 15510-1995 Electromagnetic relay for control rules for reliability test Posted 2008-06-18 2009-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Table of Contents

Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions, symbols 1 4 reliability index 3 5 Test Method 3 6 reliability verification test classification and test procedures 5 7 7 test records and test report Appendix A (informative) Recommended relay reliability test control block diagram of the detection devices 9 Determination of Annex B (informative) grading test, test the upgrade and maintenance of test programs 10

Foreword

The standard in the preparation of the format and rules in line with GB/T 1.1-2000 "Standardization Guide Part 1. The structure and coding standards Write Rules "requirements. This standard replaces GB/T 15510-1995 "control electromagnetic relay rules for reliability test." This standard and GB/T 15510-1995 compared to the main changes are as follows. --- Increasing the sample extraction; --- Increasing the detection of the box; --- Increased screening test; --- Deleted references. The Standard Appendix A, Appendix B is an informative annex. The standard proposed by China Electrical Equipment Industrial Association. This standard by the National Standardization Technical Committee measure relays and protection equipment. Drafting of this standard. National relay protection and automation equipment for Quality Supervision and Inspection Center, Hebei University, Xuchang relay Institute of Xiamen Hongfa Electroacoustic Co., Ltd. People Electric Group Co., Ltd., Ningbo Forward Relay Co., XJ Electric Co., Limited the company. The main drafters of this standard. LU Jian-guo, Liquan Xi, Li Kui, Liu, Lu Ningyi high Bunraku, Dian Wang Rong, coke slope. This standard replaces the standards previously issued as follows. --- GB/T 15510-1995. Electromagnetic relay for control rules for reliability test

1 Scope

This standard specifies the terms and their definitions, and control the amount of electromagnetic relay symbol reliability test, reliability, test methods, Reliability Verification Test classification and test procedures, test records and test reports. This standard applies to the product life it can reasonably be considered to be exponentially distributed product reliability verification tests.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 2423 (series) electric and electronic products environmental testing GB/T 14598.5-1993 Electrical relays - Part 15. Electrical characteristics of relay contacts life testing of test equipment (Idt IEC 60255-15. 1981) 3 Terms and definitions, symbols 3.1 Terms and Definitions The following terms and definitions apply to this standard. 3.1.1 Electromechanical relay generates a predetermined response by the electromagnetic force. 3.1.2 Contact voltage drop From the two terminals of a contact assembly measured voltage drop is closed between contacts. 3.1.3 Moment in a released state of the relay, under specified conditions, the amount of excitation applied at the input of the predetermined value until the instantaneous relay switch Time interval between stopping. 3.1.4 On an operating state of the relay, under specified conditions, to produce a predetermined amount from the input stimulus change (this change will cause the relay to return Only time instant back) until the moment the relay return interval. 3.1.5 Under specified conditions, it is applied to the relay, the relay can make an incentive amount of response. 3.1.6 Relay in the prescribed manner prescribed excited state.

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 15510-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 15510-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 15510-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 15510-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 15510-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15510-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.