US$329.00 ยท In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 15476-2008: Kidney function instrument Status: Valid GB/T 15476: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 15476-2008 | English | 329 |
Add to Cart
|
3 days [Need to translate]
|
Kidney function instrument
| Valid |
GB/T 15476-2008
|
| GB/T 15476-1995 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Kidney function instrument
| Obsolete |
GB/T 15476-1995
|
PDF similar to GB/T 15476-2008
Basic data | Standard ID | GB/T 15476-2008 (GB/T15476-2008) | | Description (Translated English) | Kidney function instrument | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F87 | | Classification of International Standard | 27.120 | | Word Count Estimation | 14,184 | | Date of Issue | 2008-07-02 | | Date of Implementation | 2009-04-01 | | Older Standard (superseded by this standard) | GB/T 15476-1995 | | Quoted Standard | GB/T 191; GB 4075-2003; GB/T 8993; GB 9706.1; GB/T 10257; EJ/T 1059 | | Regulation (derived from) | Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall) | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the technical requirements of renal function analyzer, test methods and inspection rules and signs, packaging, transportation and storage requirements. This standard applies to NaI (T1) crystal detector, using radionuclide human renal nuclear medicine diagnostic instruments, such products are designed, manufactured and tested basis. |
GB/T 15476-2008: Kidney function instrument---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Kidney function instrument
ICS 27.120
F87
National Standards of People's Republic of China
Replacing GB/T 15476-1995
Renal instrument
Posted 2008-07-02
2009-04-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
The standard reference IAEA IAEA-TECDOC-602-1991 "quality control of nuclear medicine equipment."
This standard replaces GB/T 15476-1995 "renal instrument."
This standard and GB/T 15476-1995 phase compare the main differences are as follows.
a) an increase of scintillation detectors, shield, working distance, point source response curve, sensitivity point source, shielding leakage of terms and definitions
(See Chapter 3);
b) increasing the relevant technical content (see Chapter 4);
c) an increase in Appendix B "point source and its structural dimensions."
The Standard Appendix A and Appendix B is a normative appendix.
The standard proposed by China National Nuclear Corporation.
This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized.
This standard was drafted. Xi'an Nuclear Instrument Factory.
The main drafters of this standard. Sun Liping, Liangping.
This standard replaces the standards previously issued as follows.
--- GB/T 15476-1995.
Renal instrument
1 Scope
This standard specifies the technical requirements of renal function meter, test methods and inspection rules and signs, packaging, transportation and storage requirements.
This standard applies to NaI (T1) detector crystals, the use of nuclear medicine diagnostic instrument body radionuclide renal function is
Class product design, manufacturing and test basis.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 191 Packaging - Pictorial signs (GB/T 191-2008, ISO 780.1997, MOD)
GB 4075-2003 Sealed radioactive sources - General requirements and classification (ISO 2919.1999, MOD)
GB/T 8993 nuclear instruments - Environmental conditions and testing procedures
GB 9706.1 Medical Electrical Equipment Part 1. General requirements for safety
GB/T 10257 nuclear instruments and nuclear radiation detectors Quality inspection rule
EJ/T 1059 Nuclear instrumentation packaging General technical requirements
3 Terms and Definitions
The following terms and definitions apply to this standard.
3.1
It refers to a region of the probe detection. In the region, when the point-like radiation source is moved in the same distance from the center of the crystal with a series of arcs
When its count rate of not less than 90% corresponding to the central axis of the crystal count rate.
3.2
In the vertical direction of the axis of the probe, point-like sources count rate of not less than 90% of the central counting rate maximum distance.
3.3
Limit detector field of view, to exclude adjacent tissue or other radioactive interference by lead or tungsten alloy material composed of a ray attenuation
Single-hole or perforated member.
3.4
Setting the pulse amplitude analyzer upper and lower thresholds. Pulses generated radioactive sources in the upper and lower threshold window falls into that part of the pulse
Count rate.
Note. Formerly known as differential count rate.
3.5
Instrument in the absence of sources of interference measured count rate, referred to as the bottom.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 15476-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 15476-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 15476-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 15476-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 15476-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 15476-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|