US$349.00 · In stock Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 10259-2013: Liquid-scintillation counting system Status: Valid GB/T 10259: Evolution and historical versions
| Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
| GB/T 10259-2013 | English | 349 |
Add to Cart
|
3 days [Need to translate]
|
Liquid-scintillation counting system
| Valid |
GB/T 10259-2013
|
| GB/T 10259-1998 | English | 399 |
Add to Cart
|
3 days [Need to translate]
|
Liquid-scintillation counting system
| Obsolete |
GB/T 10259-1998
|
| GB/T 10259-1988 | English | RFQ |
ASK
|
3 days [Need to translate]
|
Liquid-scintillation counting system
| Obsolete |
GB/T 10259-1988
|
PDF similar to GB/T 10259-2013
Basic data | Standard ID | GB/T 10259-2013 (GB/T10259-2013) | | Description (Translated English) | Liquid-scintillation counting system | | Sector / Industry | National Standard (Recommended) | | Classification of Chinese Standard | F87 | | Classification of International Standard | 17.240 | | Word Count Estimation | 15,187 | | Older Standard (superseded by this standard) | GB/T 10259-1998 | | Quoted Standard | GB/T 191-2008; GB/T 4078-2008; GB/T 8993-1998; GB 9706.1-2007; GB/T 10257-2001; GB 11806-2004; GB 18871-2002; GB/T 19661.2-2005 | | Regulation (derived from) | National Standards Bulletin 2013 No. 2 | | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China | | Summary | This standard specifies the technical requirements of a liquid scintillation counter, test methods, inspection rules and signs, packaging, transport, storage and accompanying documents. This standard applies to a liquid scintillation counter (hereinafter |
GB/T 10259-2013: Liquid-scintillation counting system---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Liquid-scintillation counting system
ICS 17.240
F87
National Standards of People's Republic of China
Replacing GB/T 10259-1998
Liquid scintillation counter
Issued on. 2013-02-07
2013-07-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Table of Contents
Preface Ⅰ
Introduction Ⅱ
1 Scope 1
2 Normative references 1
3 Terms and definitions
4 2 Technical Requirements
Test Method 4 5
6 7 inspection rules
7 signs, packaging, transportation, storage and accompanying documents 8
Appendix A (informative) Test Method repeatability standard deviation of 9
Reference 10
Table 1 liquid scintillation counter background count rate, detection efficiency and 24h instability 2
Table 2 χ2 test value 3
Table 3 Effect of the amount of error in liquid scintillation counter 4
Table 4 Reference conditions and standard test conditions and normal atmospheric conditions 4
Table 5 List of liquid scintillation counter test items 7
Foreword
This standard GB/T 1.1-2009 given rule drafting.
This standard replaces GB/T 10259-1998 "liquid scintillation counting system," compared with the GB/T 10259-1998 main technical changes are as follows.
--- The standard name be changed to "liquid scintillation counter," Concepts involved amended accordingly;
--- Introduction to increase and simplify Chapter 1, a liquid scintillation counter instructions included in the introduction;
--- Chapter 2, "Normative references", the latest files and add new files;
--- Terms and definitions of "organic solutes flashing" to "flicker substance" (see 3.7);
--- Cancel "rated operating conditions" (see the 1998 edition 4.3);
--- Modify the table Ⅱ, Ⅲ three product 24h instability of the indicator 1 (see 4.3);
--- "And affect the amount of the technical characteristics related to" in accordance with GB/T 8993-1998 "Nuclear instruments - Environmental conditions and testing methods"
4.2.2a) and 4.2.6e), c) the environmental conditions specified groups, according to Table 1 and Table 3.1 require modification of this standard in Table 3
"Temperature" and "relative humidity" two influence quantity the rated range; the "Additional error" to "affect the amount of error" (see 4.7);
--- "Standard test conditions" in accordance with the GB/T 8993-1998 requirements in Table 8 of this revised standard in Table 4, "relative humidity" of
Standard test conditions and "environmental radiation" reference conditions (see 5.1.1);
--- Increasing the repeatability standard deviation of the method, which was written in Appendix A (informative);
--- Increase in radiation safety requirements and test methods for the outer surface of the instrument (see 4.5.2 and 5.6.2);
--- "Inspection rules" in accordance with the GB/T 10257-2001 5.1 requirements of the revised standard test sequence in Table 5 and points
Group (see Chapter 6).
The standard proposed by the Defense Science and Technology Industrial Development Bureau.
This standard by the National Nuclear Instrument Standardization Technical Committee (SAC/TC30) centralized.
This standard was drafted. Xi'an Nuclear Instrument Factory.
The main drafters of this standard. Sun Liping, Yang Niying, Ren Min.
This standard replaces the previous standard release follows.
--- GB 10259-1988, GB/T 10259-1998.
Introduction
Liquid scintillation counter is radioactive sample to be tested was mixed with a scintillator to measure the radioactivity of the sample counting system, its base
The composition is as follows.
--- Sample transfer mechanism by a mechanical drive mechanism and control part of;
--- By the sample measurement chamber and photomultiplier tubes and other components of the radiation detection system;
--- Line circuit by the electronics, amplifiers, pulse height analyzer and timing counters in line with the composition of counting systems;
--- Data processing system.
Liquid scintillation counter
1 Scope
This standard specifies the liquid scintillation counter of technical requirements, test methods, inspection rules and signs, packaging, transportation, storage and accompanying
file.
This standard applies to liquid scintillation counter (hereinafter referred to as the instrument).
This standard does not include having a quenching activity calculation of unknown samples.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191-2008 Packaging - Pictorial signs
GB/T 4078-2008 radioactivity measurement sample tray, bottles and test tubes of dimensions
GB/T 8993-1998 nuclear instruments - Environmental conditions and testing procedures
GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety
GB/T 10257-2001 nuclear instruments and nuclear radiation detectors Quality inspection rule
GB 11806-2004 safe transport of radioactive materials regulations
GB 18871-2002 ionizing radiation protection and safety of radiation sources basic standards
GB/T 19661.2-2005 nuclear equipment and systems - Safety requirements - Part 2. radiation protection requirements
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Check the sample radioactivity radioactivitychecksample
Departments authorized by the state measurement of radioactive liquid containing specific radionuclide scintillation solution was sealed samples.
3.2
The bottom sample backgroundsample
Non-radioactive substances, no quenching liquid scintillation solution was sealed samples.
3.3
Count Road countingchannel
On the pulse amplitude analyzer, pulse amplitude range of the predetermined threshold.
3.4
Detection efficiency detectionefficency
Relationship between the measured value and examine the source activity between the instrument's measurement.
3.5
Background count rate backgroundcountingrate
When measuring the background sample count rate recorded by instruments.
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 10259-2013_English be delivered?Answer: Upon your order, we will start to translate GB/T 10259-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time. Question 2: Can I share the purchased PDF of GB/T 10259-2013_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 10259-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet. Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to [email protected]. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. Question 5: Should I purchase the latest version GB/T 10259-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 10259-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.
|